EDB24090SA
Square D by Schneider Electric EDB24090SA is a Miniature Circuit Breaker (MCB) designed for bolt-on mounting with a visual trip indicator. It features lugs type terminals and operates at a rated voltage of 480 V AC. This MCB serves as an Equipment Protection Device (EPD) and Circuit Breaker (CB) with a shunt trip coil, offering short-circuit and overload protection. It is equipped with aluminium lugs connection, supports a rated current of 90A, and is a 2 Pole device. The cross-section compatibility ranges from 12 to 2/0 AWG. It has a short circuit breaking rating of 25kA at 120Vac and 240Vac, and 18kA at 480Y/277Vac. The trip unit is thermal-magnetic with protection settings at a trip unit rating of 2300A.
Schneider Electric
Quick Quote
M9F53363
Schneider Electric M9F53363 is a Miniature Circuit Breaker (MCB) within the C60BPR sub-range, designed with a 3 Pole configuration and a rated current of 63A. It features a rated insulation voltage (Ui) of 500 V and a rated impulse voltage (Uimp) of 6 kV. This MCB offers a short circuit breaking rating of 10kA AIR at 120Vac, 240Vac, and 125Vdc, with a rated voltage (AC) for phase-to-phase connections at 440 V. All three poles are protected, and it operates with a D tripping curve, compliant with UL489 standards.
Schneider Electric
Quick Quote
M9F53345
Schneider Electric M9F53345 is a Miniature Circuit Breaker (MCB) within the C60BPR sub-range, designed to comply with UL489 standards. It features a 3-pole configuration and is rated for a current of 45A. The MCB has a rated insulation voltage (Ui) of 500 V and a rated impulse voltage (Uimp) of 6 kV. It offers a short circuit breaking rating of 10kA AIR at 120Vac, 240Vac, and 125Vdc. The rated voltage (AC) for phase-to-phase connections is 440 V, with all three poles protected. It operates with a D tripping curve.
Schneider Electric
Quick Quote
M9F53263
Schneider Electric M9F53263 is a Miniature Circuit Breaker (MCB) within the C60BPR sub-range, designed with a 2 Pole configuration and a rated current of 63A. It features a rated insulation voltage (Ui) of 500 V and a rated impulse voltage (Uimp) of 6 kV. This MCB offers a short circuit breaking rating of 10kA AIR at 120Vac, 240Vac, and 125Vdc, with a rated voltage (AC) for phase-to-phase connections at 440 V. Both poles are protected, and it operates with a D tripping curve.
Schneider Electric
Quick Quote
M9F53250
Schneider Electric M9F53250 is a Miniature Circuit Breaker (MCB) within the C60BPR sub-range, designed with a 2 Pole configuration and a rated current of 50A. It features a rated insulation voltage (Ui) of 500 V and a rated impulse voltage (Uimp) of 6 kV. This MCB offers a short circuit breaking rating of 10kA AIR at 120Vac, 240Vac, and 125Vdc. It is designed for a rated voltage (AC) phase-to-phase of 440 V and protects 2 poles. The tripping curve for this breaker is classified as D, and it is compliant with UL489 standards.
Schneider Electric
Quick Quote
M9F53245
Schneider Electric M9F53245 is a Miniature Circuit Breaker (MCB) within the C60BPR sub-range, designed to comply with UL489 standards. This 2-pole MCB has a rated current of 45A and features a rated insulation voltage (Ui) of 500V, with a rated impulse voltage (Uimp) of 6kV. It offers a short circuit breaking rating of 10kA AIR at 120Vac, 240Vac, and 125Vdc. The M9F53245 operates with a rated voltage (AC) for phase-to-phase connections at 440V and protects 2 poles. It is equipped with a D tripping curve.
Schneider Electric
Quick Quote
M9F53163
Schneider Electric M9F53163 is a Miniature Circuit Breaker (MCB) within the C60BPR sub-range, designed for a single pole configuration. It features a rated current of 63A and operates with a rated insulation voltage (Ui) of 500V. The MCB is engineered to withstand rated impulse voltages (Uimp) up to 6kV and offers a short circuit breaking rating of 10kA AIR across 120Vac, 240Vac, and 60Vdc. It supports a rated voltage (AC) for phase-to-phase connections up to 440V. This product ensures protection for 1 pole and is characterized by a D tripping curve, compliant with UL489 standards.
Schneider Electric
Quick Quote
M9F53150
Schneider Electric M9F53150 is a Miniature Circuit Breaker (MCB) within the C60BPR sub-range, designed for a single-pole configuration. It features a rated current of 50A and is compliant with UL489 standards. The MCB has a rated insulation voltage (Ui) of 500V and a rated impulse voltage (Uimp) of 6kV. It offers a short circuit breaking rating of 10kA AIR at 120Vac, 240Vac, and 60Vdc. The rated voltage (AC) for phase-to-phase connections is 440V, with one protected pole. It operates with a D tripping curve.
Schneider Electric
Quick Quote
M9F53145
Schneider Electric M9F53145 is a Miniature Circuit Breaker (MCB) within the C60BPR sub-range, designed for a single pole configuration. It features a rated current of 45A and is compliant with UL489 standards. The MCB has a rated insulation voltage (Ui) of 500 V and a rated impulse voltage (Uimp) of 6 kV. It offers a short circuit breaking rating of 10kA AIR at 120Vac, 240Vac, and 60Vdc. The rated voltage (AC) for phase-to-phase connections is 440 V, with one protected pole. It operates with a D tripping curve.
Schneider Electric
Quick Quote
M9F43345
Schneider Electric M9F43345 is a Miniature Circuit Breaker (MCB) within the C60BP sub-range, designed to comply with UL489 standards. This 3 Pole MCB has a rated current of 45A and features a rated insulation voltage (Ui) of 500V, with a DC rated voltage of 60Vdc. It is equipped to handle rated impulse voltage (Uimp) of 6kV. The short circuit breaking rating is specified at 14kA AIR for both 120Vac and 240Vac, and 10kA AIR for 480Y/277Vac as well as 60Vdc. For AC applications, it supports a rated voltage of 240V phase-to-neutral and 415V phase-to-phase. All three poles are protected, and it operates with a D tripping curve.
Schneider Electric
Quick Quote
M9F43263
Schneider Electric M9F43263 is a Miniature Circuit Breaker (MCB) within the C60BP sub-range, designed for two-pole protection with a rated current of 63A. It features a rated insulation voltage (Ui) of 500V, a DC rated voltage of 60Vdc, and an AC rated voltage of 240V phase-to-neutral and 415V phase-to-phase. The M9F43263 has a rated impulse voltage (Uimp) of 6kV and offers a short circuit breaking rating of 14kA AIR at both 120Vac and 240Vac, and 10kA AIR at 480Y/277Vac and 60Vdc. Both poles are protected, and it is equipped with a D tripping curve. This MCB is compliant with UL489 standards.
Schneider Electric
Quick Quote
M9F43245
Schneider Electric M9F43245 is a Miniature Circuit Breaker (MCB) within the C60BP sub-range, designed with a 2 Pole configuration and a rated current of 45A. It features a rated insulation voltage (Ui) of 500 V, a DC rated voltage of 60Vdc, and an impulse voltage (Uimp) rating of 6 kV. This MCB offers a short circuit breaking rating of 14kA AIR at both 120Vac and 240Vac, and 10kA AIR at 480Y/277Vac and 60Vdc. It supports a rated voltage (AC) of 240 V phase-to-neutral and 415 V phase-to-phase, with both poles protected. The tripping curve is classified as D.
Schneider Electric
Quick Quote
M9F43163
Schneider Electric M9F43163 is a Miniature Circuit Breaker (MCB) within the C60BP sub-range, designed for a single pole configuration. It features a rated current of 63A and is compliant with UL489 standards. The MCB has a rated insulation voltage (Ui) of 500V, a DC rated voltage of 60Vdc, and an AC rated voltage of 240V phase-to-neutral and 415V phase-to-phase. It is equipped with a rated impulse voltage (Uimp) of 6kV and offers a short circuit breaking rating of 14kA AIR at both 120Vac and 240Vac, and 10kA AIR at 277Vac and 60Vdc. The protected pole count is 1, and it operates with a D tripping curve.
Schneider Electric
Quick Quote
M9F43150
Schneider Electric M9F43150 is a Miniature Circuit Breaker (MCB) within the C60BP sub-range, designed to comply with UL489 standards. It features a single pole configuration and is rated for a current of 50A. The MCB has a rated insulation voltage (Ui) of 500V, with a DC rated voltage of 60Vdc and an AC rated voltage of 240V phase-to-neutral and 415V phase-to-phase. It is equipped to handle rated impulse voltage (Uimp) of 6kV. The short circuit breaking rating is specified at 14kA AIR for both 120Vac and 240Vac, and 10kA AIR for 277Vac and 60Vdc. The protected pole count is one, and it operates with a D tripping curve.
Schneider Electric
Quick Quote
M9F43145
Schneider Electric M9F43145 is a Miniature Circuit Breaker (MCB) within the C60BP sub-range, designed for a single pole configuration. It features a rated current of 45A and is compliant with UL489 standards. The MCB has a rated insulation voltage (Ui) of 500V, a DC rated voltage of 60Vdc, and an AC rated voltage of 240V phase-to-neutral and 415V phase-to-phase. It is equipped with a rated impulse voltage (Uimp) of 6kV and offers a short circuit breaking rating of 14kA AIR at both 120Vac and 240Vac, and 10kA AIR at 277Vac and 60Vdc. The device protects one pole and operates with a D tripping curve.
Schneider Electric
Quick Quote
M9F23463
Schneider Electric M9F23463 is a Miniature Circuit Breaker (MCB) within the C60SP sub-range, designed with a 4 Pole configuration and a rated current of 63A. It features a short circuit breaking rating of 14kA AIR at 240Vac and 10kA AIR at 480Y/277Vac. All four poles are protected, and it operates with a D tripping curve. This MCB is compliant with UL1077 standards.
Schneider Electric
Quick Quote
M9F23450
Schneider Electric M9F23450 is a Miniature Circuit Breaker (MCB) within the C60SP sub-range, designed with a 4 Pole configuration and a rated current of 50A. It features a short circuit breaking rating of 14kA AIR at 240Vac and 10kA AIR at 480Y/277Vac. All four poles are protected, and it operates with a D tripping curve. This MCB is compliant with UL1077 standards.
Schneider Electric
Quick Quote
M9F23445
Schneider Electric M9F23445 is a Miniature Circuit Breaker (MCB) within the C60SP sub-range, designed with 4 poles and a rated current of 45A. It features a short circuit breaking rating of 14kA AIR at 240Vac and 10kA AIR at 480Y/277Vac. All four poles are protected, and it operates with a D tripping curve. This MCB is compliant with UL1077 standards.
Schneider Electric
Quick Quote
M9F23363
Schneider Electric M9F23363 is a Miniature Circuit Breaker (MCB) within the C60SP sub-range, designed to provide circuit protection. It features a 3 Pole configuration and is rated for a current of 63A. This MCB has a short circuit breaking rating of 14kA AIR at 240Vac and 10kA AIR at 480Y/277Vac, with all three poles protected. It operates with a D tripping curve.
Schneider Electric
Quick Quote
M9F23345
Schneider Electric M9F23345 is a Miniature Circuit Breaker (MCB) within the C60SP sub-range, designed to provide circuit protection. It features a 3 Pole configuration and is rated for a current of 45A. This MCB has a short circuit breaking rating of 14kA AIR at 240Vac and 10kA AIR at 480Y/277Vac, with all three poles protected. It operates with a D tripping curve.
Schneider Electric
Quick Quote
Items per page: