LV430302
Schneider Electric LV430302 is a Moulded Case Circuit Breaker (MCCB) within the NSX160B sub-range. This MCCB features a lug connection type and is designed with 3 poles. It offers thermal protection for overload scenarios and magnetic protection for short-circuit conditions. The rated current for this device is 100A, with a rated insulation voltage (Ui) of 800 V. Its protection settings include a short-circuit pickup current fixed at 800A. The LV430302 has a rated impulse voltage (Uimp) of 8 kV and a trip current rating of 100 AT. The frame current rating stands at 160 AF. It boasts mechanical durability of 40,000 operations at no load and electrical durability of 40,000 operations at 440Vac; In/2 and 20,000 operations at 440Vac; In. The rated voltage (AC) phase-to-phase is 690 V, with 2 poles protected. The trip unit type is a TMD Interchangeable Thermal-Magnetic (adjustable), and it falls under the utilisation category A.
Schneider Electric
Quick Quote
LV430301
Schneider Electric LV430301 is a Moulded Case Circuit Breaker (MCCB) within the NSX160B sub-range, designed for lug connection and equipped with three poles. It features thermal protection for overload scenarios and magnetic protection against short-circuits. The rated current for this device is 125A, with a rated insulation voltage (Ui) of 800 V and a protection setting for short-circuit pickup current fixed at 1250A. It has a rated impulse voltage (Uimp) of 8 kV and a trip current rating of 125 AT, with a frame current rating of 160 AF. The mechanical durability of the LV430301 is rated at 40,000 operations at no load, and its electrical durability is rated at 40,000 operations at 440Vac with half the rated current (In/2) and 20,000 operations at 440Vac with the rated current (In). The rated voltage (AC) phase-to-phase is 690 V, with two poles protected. It utilizes a TMD interchangeable thermal-magnetic trip unit that is adjustable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV430300
Schneider Electric LV430300 is a Moulded Case Circuit Breaker (MCCB) within the NSX160B sub-range, designed for lug connection and equipped with three poles. It features thermal protection for overload scenarios and magnetic protection for short-circuit conditions. The rated current for this device is 160A, with a rated insulation voltage (Ui) of 800 V. Protection settings include over-current adjustable from 0.7 to 1.0 times the rated current (In) and a fixed short-circuit pickup current of 1250A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating and frame current rating both at 160 AT and 160 AF, respectively. It offers mechanical durability of 40,000 operations at no load and electrical durability of 40,000 operations at 440Vac with half the rated current and 20,000 operations at 440Vac with the rated current. The rated voltage (AC) phase-to-phase is 690 V, with two poles protected. The trip unit type is a TMD Interchangeable Thermal-Magnetic, adjustable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV429961
Schneider Electric LV429961 is a Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection, part of the NSX100B Vigi sub-range. This 4-pole device features lug connection type and offers thermal protection (overload), magnetic protection (short-circuit), and earth leakage protection (Vigi). It has a rated current of 80A, with a rated insulation voltage (Ui) of 800V. The protection settings are adjustable for over-current from 0.7 to 1.0 times the rated current (In) and have a fixed short-circuit pickup current of 640A. The rated impulse voltage (Uimp) is 8kV, and the residual current sensitivity is adjustable between 30mA and 10A. The trip current rating is 80 AT, with a frame current rating of 100 AF. Mechanical durability is rated at 50,000 operations at no load, and electrical durability is rated at 50,000 operations at 440Vac with half the rated current (In/2) and 30,000 operations at 440Vac with the rated current (In). The rated voltage (AC) phase-to-phase is 690V, with all four poles protected. The trip unit type is TMD Interchangeable Thermal-Magnetic, adjustable, and the time delay for tripping is adjustable between 0 and 800ms. It falls under utilisation category A.
Schneider Electric
Quick Quote
LV429960
Schneider Electric LV429960 is a Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection, part of the NSX100B Vigi sub-range. This 4-pole device features lug connection type and offers thermal protection (overload), magnetic protection (short-circuit), and earth leakage protection (Vigi). It has a rated current of 100A, with a rated insulation voltage (Ui) of 800 V. The protection settings are adjustable for over-current from 0.7 - 1.0 x In, with a fixed short-circuit pickup current at 800A. The rated impulse voltage (Uimp) is 8 kV, and it has an adjustable residual current sensitivity of 30; 300; 1000; 3000; 10000mA / 0.03; 0.3; 1; 3; 10A. The trip current rating is 100 AT, and the frame current rating is 100 AF. Mechanical durability is rated at 50,000 operations at no load, and electrical durability is rated at 50,000 operations at 440Vac; In/2 and 30,000 operations at 440Vac; In. The rated voltage (AC) phase-to-phase is 690 V, with all 4 poles protected. The trip unit type is TMD Interchangeable Thermal-Magnetic (adjustable), with an adjustable time delay for tripping of 0-40; 60-140; 150-300;310-800ms / 0-0.04; 0.06-0.14; 0.15-0.3; 0.31-0.8 s. It falls under utilisation category A.
Schneider Electric
Quick Quote
LV429800
Schneider Electric LV429800 is a Moulded Case Circuit Breaker (MCCB) within the NSX100H sub-range, designed for lug connection and featuring 4 poles. It offers protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current is 100A, with a rated insulation voltage (Ui) of 800 V. Protection settings are adjustable for L (Long-time protection) from 0.4 to 1 x In and S0 (Short-time protection with fixed time delay) from 1.5 to 10 x Ir, while I (Instantaneous protection) is fixed at 1500A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 100 AT and a frame current rating of 100 AF. Mechanical durability is rated at 50,000 operations at no load, and electrical durability at 50,000 operations (440Vac; In/2) and 30,000 operations (440Vac; In) with load. The rated voltage (AC) phase-to-phase is 690 V, with all 4 poles protected. It features a Micrologic 2.2 (LI) interchangeable electronic trip unit and falls under utilisation category A.
Schneider Electric
Quick Quote
LV429792
Schneider Electric LV429792 is a Moulded Case Circuit Breaker (MCCB) within the NSX100H sub-range, designed for lug connection and featuring 3 poles. It offers protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current is 40A, with a rated insulation voltage (Ui) of 800 V. Protection settings are adjustable for L (Long-time protection) from 0.4 to 1 x In and S0 (Short-time protection with fixed time delay) from 1.5 to 10 x Ir, while I (Instantaneous protection) is fixed at 600A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 40 AT and a frame current rating of 100 AF. Mechanical durability is rated at 50,000 operations at no load, and electrical durability at 50,000 operations (440Vac; In/2) and 30,000 operations (440Vac; In) with load. The rated voltage (AC) phase-to-phase is 690 V, with all 3 poles protected. It features a Micrologic 2.2 (LI) interchangeable electronic trip unit and falls under utilisation category A.
Schneider Electric
Quick Quote
LV429790
Schneider Electric LV429790 is a Moulded Case Circuit Breaker (MCCB) within the NSX100H sub-range, designed for lug connection and featuring 3 poles. It offers protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current is 100A, with a rated insulation voltage (Ui) of 800 V. Protection settings are adjustable for L (Long-time protection) from 0.4 to 1 x In and S0 (Short-time protection with fixed time delay) from 1.5 to 10 x Ir, while I (Instantaneous protection) is fixed at 1500A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 100 AT and a frame current rating of 100 AF. Mechanical durability is rated at 50,000 operations at no load, and electrical durability at 50,000 operations (440Vac; In/2) and 30,000 operations (440Vac; In) with load. The rated voltage (AC) phase-to-phase is 690 V, with all 3 poles protected. It features a Micrologic 2.2 (LI) interchangeable electronic trip unit and falls under utilisation category A.
Schneider Electric
Quick Quote
LV429677
Schneider Electric LV429677 is a Moulded Case Circuit Breaker (MCCB) within the NSX100H sub-range, designed for lug connection and featuring 3 poles. It offers thermal protection for overload scenarios and magnetic protection against short-circuits. The rated current is 16A, with a rated insulation voltage (Ui) of 800 V. Protection settings include over-current adjustable from 0.7 - 1.0 x In and a fixed short-circuit pickup current at 190A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 16 AT and a frame current rating of 100 AF. Mechanical durability is rated at 50,000 operations at no load, while electrical durability is rated at 50,000 operations at 440Vac with half the rated current (In/2) and 30,000 operations at 440Vac with the rated current (In). The rated voltage for phase-to-phase connections is 690 V, with all three poles protected. The trip unit type is a TMD Interchangeable Thermal-Magnetic, adjustable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV429675
Schneider Electric LV429675 is a Moulded Case Circuit Breaker (MCCB) within the NSX100H sub-range, designed for lug connection and featuring 3 poles. It offers thermal protection for overload scenarios and magnetic protection against short-circuits. The rated current for this device is 32A, with a rated insulation voltage (Ui) of 800V. Protection settings include over-current adjustable from 0.7 to 1.0 times the rated current (In) and a fixed short-circuit pickup current of 400A. The rated impulse voltage (Uimp) stands at 8kV, with a trip current rating of 32 AT and a frame current rating of 100 AF. It boasts a mechanical durability of 50,000 operations at no load and an electrical durability of 50,000 operations at 440Vac with half the rated current, and 30,000 operations at 440Vac with the rated current. The rated voltage for phase-to-phase connections is 690V, and all three poles are protected. The trip unit type is a TMD Interchangeable Thermal-Magnetic, adjustable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV429674
Schneider Electric LV429674 is a Moulded Case Circuit Breaker (MCCB) within the NSX100H sub-range, designed for lug connection and equipped with three poles. It offers thermal protection for overload scenarios and magnetic protection against short-circuits. The rated current for this device is 40A, with a rated insulation voltage (Ui) of 800 V. Protection settings include over-current adjustable from 0.7 to 1.0 times the rated current (In) and a fixed short-circuit pickup current of 500A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 40 AT and a frame current rating of 100 AF. It boasts a mechanical durability of 50,000 operations at no load and an electrical durability of 50,000 operations at 440Vac with half the rated current (In/2), and 30,000 operations at 440Vac with the rated current (In). The rated voltage (AC) for phase-to-phase connections is 690 V, with all three poles protected. The trip unit type is a TMD Interchangeable Thermal-Magnetic, adjustable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV429673
Schneider Electric LV429673 is a Moulded Case Circuit Breaker (MCCB) within the NSX100H sub-range, designed for lug connection and featuring 3 poles. It offers thermal protection for overload scenarios and magnetic protection for short-circuit conditions. The rated current is 50A, with a rated insulation voltage (Ui) of 800 V. Protection settings include over-current adjustable from 0.7 - 1.0 x In and a fixed short-circuit pickup current at 500A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 50 AT and a frame current rating of 100 AF. Mechanical durability is noted at 50,000 operations at no load, while electrical durability is specified as 50,000 operations at 440Vac with half the rated current (In/2) and 30,000 operations at 440Vac with the rated current (In). The rated voltage for phase-to-phase applications is 690 V, with all three poles protected. The trip unit type is a TMD Interchangeable Thermal-Magnetic, adjustable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV429672
Schneider Electric LV429672 is a Moulded Case Circuit Breaker (MCCB) within the NSX100H sub-range, designed for lug connection and featuring 3 poles. It offers thermal protection for overload scenarios and magnetic protection for short-circuit conditions. The rated current is 63A, with a rated insulation voltage (Ui) of 800 V. Protection settings include over-current adjustable from 0.7 - 1.0 x In and a fixed short-circuit pickup current at 500A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 63 AT and a frame current rating of 100 AF. Mechanical durability is noted at 50,000 operations at no load, and electrical durability at 50,000 operations for 440Vac; In/2 and 30,000 operations for 440Vac; In. The rated voltage for phase-to-phase is 690 V, with all 3 poles protected. The trip unit type is a TMD Interchangeable Thermal-Magnetic, adjustable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV429671
Schneider Electric LV429671 is a Moulded Case Circuit Breaker (MCCB) within the NSX100H sub-range. This MCCB features a lug connection type and is designed with 3 poles. It offers thermal protection for overload scenarios and magnetic protection for short-circuit conditions. The rated current for this device is 80A, with a rated insulation voltage (Ui) of 800 V. Protection settings include over-current adjustable from 0.7 - 1.0 x In and a fixed short-circuit pickup current at 640A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 80 AT and a frame current rating of 100 AF. Mechanical durability is rated at 50,000 operations at no load, while electrical durability is rated at 50,000 operations at 440Vac with half the rated current (In/2) and 30,000 operations at 440Vac with the rated current (In). The rated voltage (AC) phase-to-phase is 690 V, with all three poles protected. The trip unit type is a TMD Interchangeable Thermal-Magnetic, adjustable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV429651
Schneider Electric LV429651 is a Moulded Case Circuit Breaker (MCCB) within the NSX100F sub-range, designed with a lug connection type and featuring 4 poles. It offers thermal protection for overload scenarios and magnetic protection against short-circuits. The rated current for this device is 80A, with a rated insulation voltage (Ui) of 800 V. Protection settings include over-current adjustable from 0.7 - 1.0 x In, a short-circuit pickup current fixed at 640A, and a fully protected neutral pickup current of 1 x Ir. It has a rated impulse voltage (Uimp) of 8 kV and a trip current rating of 80 AT. The frame current rating stands at 100 AF. Mechanical durability is rated at 50,000 operations at no load, while electrical durability is rated at 50,000 operations at 440Vac; In/2 and 30,000 operations at 440Vac; In. The rated voltage (AC) phase-to-phase is 690 V, with all 4 poles protected. The trip unit type is a TMD Interchangeable Thermal-Magnetic (adjustable), and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV429650
Schneider Electric LV429650 is a Moulded Case Circuit Breaker (MCCB) within the NSX100F sub-range. This 4-pole MCCB features lug connection type and offers thermal protection for overload scenarios and magnetic protection against short-circuits. It has a rated current of 100A and operates with a rated insulation voltage (Ui) of 800 V. The protection settings include over-current adjustable from 0.7 to 1.0 times the rated current (In), with a short-circuit pickup current fixed at 800A and a fully protected neutral pickup current of 1 times the rated current (Ir). The rated impulse voltage (Uimp) stands at 8 kV, and it has a trip current rating of 100 AT with a frame current rating of 100 AF. The mechanical durability of the LV429650 is rated at 50,000 operations at no load, and its electrical durability is rated at 50,000 operations at 440Vac with half the rated current (In/2) and 30,000 operations at 440Vac with the rated current (In). It supports a rated voltage (AC) phase-to-phase of 690 V, with all 4 poles protected. The trip unit type is a TMD Interchangeable Thermal-Magnetic, adjustable, and it falls under the utilisation category A.
Schneider Electric
Quick Quote
LV429637
Schneider Electric LV429637 is a Moulded Case Circuit Breaker (MCCB) within the NSX100F sub-range, designed for lug connection and featuring 3 poles. It offers thermal protection for overload scenarios and magnetic protection against short-circuits. The rated current is 16A, with a rated insulation voltage (Ui) of 800 V. Protection settings include over-current adjustable from 0.7 - 1.0 x In and a fixed short-circuit pickup current at 190A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 16 AT and a frame current rating of 100 AF. Mechanical durability is noted at 50,000 operations at no load, and electrical durability at 50,000 operations for 440Vac; In/2 and 30,000 operations for 440Vac; In. The rated voltage (AC) phase-to-phase is 690 V, with all 3 poles protected. The trip unit type is a TMD Interchangeable Thermal-Magnetic (adjustable), and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV429636
Schneider Electric LV429636 is a Moulded Case Circuit Breaker (MCCB) within the NSX100F sub-range. This MCCB features a lug connection type and is designed with 3 poles. It offers thermal protection for overload scenarios and magnetic protection for short-circuit conditions. The rated current for this device is 25A, with a rated insulation voltage (Ui) of 800 V. Protection settings are adjustable for over-current from 0.7 to 1.0 times the rated current (In) and have a fixed short-circuit pickup current at 300A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 25 AT and a frame current rating of 100 AF. It boasts mechanical durability of 50,000 operations at no load and electrical durability of 50,000 operations at 440Vac with half the rated current (In/2), and 30,000 operations at 440Vac with the rated current (In). The rated voltage (AC) phase-to-phase is 690 V, with all 3 poles protected. The trip unit type is a TMD Interchangeable Thermal-Magnetic, adjustable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV429634
Schneider Electric LV429634 is a Moulded Case Circuit Breaker (MCCB) within the NSX100F sub-range, designed with a lug connection type and three poles. It features thermal protection for overload scenarios and magnetic protection for short-circuit conditions. The rated current is 40A, with a rated insulation voltage (Ui) of 800 V. Protection settings include over-current adjustable from 0.7 - 1.0 x In and a short-circuit pickup current fixed at 500A. The rated impulse voltage (Uimp) stands at 8 kV, and the trip current rating is 40 AT, with a frame current rating of 100 AF. Mechanical durability is rated at 50,000 operations without load, and electrical durability is specified as 50,000 operations at 440Vac with half the rated current (In/2) and 30,000 operations at 440Vac with the rated current (In). The rated voltage for phase-to-phase connections is 690 V, with all three poles protected. The trip unit type is a TMD Interchangeable Thermal-Magnetic, adjustable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV429633
Schneider Electric LV429633 is a Moulded Case Circuit Breaker (MCCB) within the NSX100F sub-range, designed for lug connection and featuring three poles. It offers thermal protection for overload scenarios and magnetic protection for short-circuit conditions. The rated current is 50A, with a rated insulation voltage (Ui) of 800 V. Protection settings include over-current adjustable from 0.7 to 1.0 times the rated current (In) and a fixed short-circuit pickup current of 500A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 50 AT and a frame current rating of 100 AF. Mechanical durability is specified at 50,000 operations at no load, while electrical durability is rated at 50,000 operations at 440Vac with half the rated current and 30,000 operations at 440Vac with the rated current. The rated voltage for phase-to-phase connections is 690 V, with all three poles protected. The trip unit type is a TMD Interchangeable Thermal-Magnetic, adjustable, and it falls under utilisation category A.
Schneider Electric
Quick Quote