Filters
Molded Case Circuit Breakers (MCCB)
part#
description
manufacturer
LV429100
Schneider Electric LV429100 is a trip unit designed for use in electrical circuit protection. It belongs to the Micrologic 5.2A (LSI) sub-range and functions solely as a trip unit. This model is equipped with four poles and offers three main protection functions: L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current for this unit is 100A. Protection settings include long-time protection adjustable from 0.4 to 1 times the rated current, short-time protection with an adjustable time delay ranging from 1.5 to 15 times the rated current and a time delay from 0.1 to 0.4 seconds, and instantaneous protection adjustable from 1.5 to 15 times the rated current. The trip current rating stands at 100 AT, and it protects all four poles. The LV429100 features an interchangeable electronic Micrologic 5.2A (LSI) trip unit type and includes measurement functions for I1, I2, I3, IN, Imax, Iground, and percentage of unbalance.
Schneider Electric
Quick Quote
LV429096
Schneider Electric LV429096 is a trip unit designed for use in electrical protection systems. It belongs to the Micrologic 5.2E (LSI) sub-range and is characterized by its 3 Pole configuration. This unit is equipped with L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection) functions. It has a rated current of 40A and offers adjustable protection settings including long-time protection adjustable from 0.4 to 1 x In, short-time protection with an adjustable time delay from 1.5 to 15 x Ir (time delay from 0.1 to 0.4s), and instantaneous protection adjustable from 1.5 to 15 x In. The trip current rating stands at 40 AT, and it protects 3 Poles. As an interchangeable electronic trip unit type, the Micrologic 5.2E (LSI) also features comprehensive measurement functions such as I1, I2, I3, IN, Imax, Iground% unbalance%, U12, U23, U31, V1N, V2N, V3N, Uavg, Vavg, Voltage unbalance, phase sequence, P, Q, S, cos phi, Energy (kWh; kVAh; kVARh), demand current/power with an adjustable time window, THDu, THDv, and THDi.
Schneider Electric
Quick Quote
LV429095
Schneider Electric LV429095 is a trip unit designed for use in electrical protection systems. It belongs to the Micrologic 5.2E (LSI) sub-range and functions solely as a trip unit. This model is equipped with three poles and offers protection functions including Long-time protection (L), Short-time protection with fixed time delay (S0), and Instantaneous protection (I). The rated current for this unit is 100A, with protection settings for Long-time protection adjustable from 0.4 to 1 times the rated current (In), Short-time protection adjustable from 1.5 to 15 times the rated current (Ir) with a time delay ranging from 0.1 to 0.4 seconds, and Instantaneous protection adjustable from 1.5 to 15 times the rated current (In). The trip current rating stands at 100 AT, and it protects all three poles. The LV429095 features an interchangeable electronic Micrologic 5.2E (LSI) trip unit type. Its measurement functions include current (I1, I2, I3, IN, Imax), ground current percentage unbalance, voltage (U12, U23, U31, V1N, V2N, V3N, Uavg, Vavg), voltage unbalance, phase sequence, power (P, Q, S), power factor (cos phi), energy (kWh, kVAh, kVARh), demand current/power with an adjustable time window, and total harmonic distortion for voltage (THDv), current (THDi), and voltage unbalance (THDu).
Schneider Electric
Quick Quote
LV429091
Schneider Electric LV429091 is a trip unit designed for use in electrical circuit protection. It belongs to the Micrologic 5.2A (LSI) sub-range and is characterized by its 3 Pole configuration. This unit is equipped with L (Long-time), S0 (Short-time with fixed time delay), and I (Instantaneous) protection functions. It has a rated current of 40A and offers adjustable protection settings including long-time protection adjustable from 0.4 to 1 x In, short-time protection with an adjustable time delay from 1.5 to 15 x Ir and a time delay range from 0.1 to 0.4s, and instantaneous protection adjustable from 1.5 to 15 x In. The trip current rating is 40 AT, and it protects 3 poles. The LV429091 is an interchangeable electronic trip unit type and features measurement functions for I1, I2, I3, IN, Imax, Iground, and percentage unbalance.
Schneider Electric
Quick Quote
LV429090
Schneider Electric LV429090 is a trip unit designed for use in electrical circuit protection. It belongs to the Micrologic 5.2A (LSI) sub-range and functions solely as a trip unit. This model is equipped with three poles and offers protection functions including Long-time protection (L), Short-time protection with fixed time delay (S0), and Instantaneous protection (I). The rated current for this unit is 100A. Protection settings are adjustable, with Long-time protection (L) ranging from 0.4 to 1 times the rated current (In), Short-time protection (S) with an adjustable time delay ranging from 1.5 to 15 times the rated current (Ir) and a time delay from 0.1 to 0.4 seconds, and Instantaneous protection (I) adjustable from 1.5 to 15 times the rated current (In). The trip current rating stands at 100 AT, and it protects all three poles. The LV429090 features an interchangeable electronic Micrologic 5.2A (LSI) trip unit type and includes measurement functions for current (I1, I2, I3, IN, Imax) and ground unbalance percentage.
Schneider Electric
Quick Quote
LV429086
Schneider Electric LV429086 is a trip unit designed for use in electrical circuit protection. It is part of the Micrologic 2.2G (LI) sub-range and functions as a trip unit alone. This model is equipped with four poles and offers three protection functions: L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current for this unit is 40A. Its protection settings include long-time protection adjustable from 0.4 to 1 x In, short-time protection with fixed time delay adjustable from 1.5 to 10 x Ir, and instantaneous protection fixed at 600A. The trip current rating is 40 AT, and it protects all four poles. The LV429086 features an interchangeable electronic trip unit type Micrologic 2.2G (LI).
Schneider Electric
Quick Quote
LV429085
Schneider Electric LV429085 is a trip unit designed for use in electrical circuit protection. It belongs to the Micrologic 2.2G (LI) sub-range and functions solely as a trip unit. This model is equipped with four poles and offers three protection functions: L (Long-time protection), S0 (Short-time protection with a fixed time delay), and I (Instantaneous protection). The rated current for this unit is 100A. Its protection settings include long-time protection adjustable from 0.4 to 1 times the rated current (In), short-time protection with a fixed time delay adjustable from 1.5 to 10 times the rated current (Ir), and instantaneous protection fixed at 1500A. The trip current rating stands at 100 AT, and it protects all four poles. The LV429085 features an interchangeable electronic trip unit type, specifically the Micrologic 2.2G (LI).
Schneider Electric
Quick Quote
LV429082
Schneider Electric LV429082 is a trip unit designed for use in electrical circuit protection. It belongs to the Micrologic 2.2 (LI) sub-range and functions solely as a trip unit. This model is equipped with four poles and offers three protection functions: L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current for this unit is 40A. Its protection settings include long-time protection adjustable from 0.4 to 1 times the rated current, short-time protection with fixed time delay adjustable from 1.5 to 10 times the rated current, and instantaneous protection fixed at 600A. The trip current rating stands at 40 AT, and it is designed to protect all four poles. The LV429082 features an interchangeable electronic trip unit type, Micrologic 2.2 (LI).
Schneider Electric
Quick Quote
LV429076
Schneider Electric LV429076 is a trip unit designed for use in electrical circuit protection. It belongs to the Micrologic 2.2G (LI) sub-range and functions solely as a trip unit. This model is compatible with 3 Pole(s) systems and offers a variety of protection functions, including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current for this unit is 40A, with protection settings adjustable as follows: L (Long-time protection) from 0.4 to 1 x In, S0 (Short-time protection with fixed time delay) from 1.5 to 10 x Ir, and I (Instantaneous protection) is fixed at 600A. The trip current rating stands at 40 AT, and it is designed to protect 3 Pole(s). The LV429076 features an interchangeable electronic trip unit type, specifically the Micrologic 2.2G (LI).
Schneider Electric
Quick Quote
LV429075
Schneider Electric LV429075 is a trip unit designed for use in electrical circuit protection. It belongs to the Micrologic 2.2G (LI) sub-range and functions solely as a trip unit. This model is compatible with 3 Pole(s) systems and offers a variety of protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current for this unit is 100A. Its protection settings are adjustable for L (Long-time protection) from 0.4 to 1 x In, and for S0 (Short-time protection with fixed time delay) from 1.5 to 10 x Ir, while the I (Instantaneous protection) is fixed at 1500A. The trip current rating stands at 100 AT, and it is designed to protect 3 Pole(s). The trip unit type is specified as Micrologic 2.2G (LI) and is an interchangeable electronic component.
Schneider Electric
Quick Quote
LV429072
Schneider Electric LV429072 is a trip unit designed for use in electrical circuit protection. It belongs to the Micrologic 2.2 (LI) sub-range and functions solely as a trip unit. This model is compatible with 3 Pole(s) systems and offers a variety of protection functions, including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current for this unit is 40A. Its protection settings are adjustable, with long-time protection (L) ranging from 0.4 to 1 x In, short-time protection (S0) from 1.5 to 10 x Ir, and instantaneous protection (I) fixed at 600A. The trip current rating stands at 40 AT, and it is designed to protect 3 Pole(s). The LV429072 features an interchangeable electronic trip unit type, specifically the Micrologic 2.2 (LI).
Schneider Electric
Quick Quote
LV429070
Schneider Electric LV429070 is a trip unit designed for use in electrical circuit protection. It belongs to the Micrologic 2.2 (LI) sub-range and functions solely as a trip unit. This model is compatible with 3 Pole(s) systems and offers a variety of protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current for this unit is 100A, with protection settings adjustable for L (Long-time protection) from 0.4 to 1 x In, S0 (Short-time protection with fixed time delay) from 1.5 to 10 x Ir, and a fixed I (Instantaneous protection) at 1500A. The trip current rating stands at 100 AT, ensuring all 3 poles are protected. This trip unit is an interchangeable electronic component, enhancing its versatility in various electrical protection applications.
Schneider Electric
Quick Quote
LV429057
Schneider Electric LV429057 is a 4-pole trip unit designed for thermal and magnetic protection. It falls under the TMD sub-range, functioning solely as a trip unit. This model offers thermal protection against overload and magnetic protection against short-circuits. It has a rated current of 16A, with over-current protection settings adjustable from 0.7 to 1.0 times the rated current (In). The short-circuit pickup current is fixed at 190A, and the fully protected neutral pickup current is set at 1 times the rated current (Ir). The LV429057 features an interchangeable thermal-magnetic (adjustable) trip unit type, ensuring all four poles are protected.
Schneider Electric
Quick Quote
LV429056
Schneider Electric LV429056 is a 4-pole trip unit designed for thermal and magnetic protection. It falls under the TMD sub-range, functioning solely as a trip unit. This model offers thermal protection against overload and magnetic protection against short-circuits. It has a rated current of 25A, with over-current protection settings adjustable from 0.7 to 1.0 times the rated current (In). The short-circuit pickup current is fixed at 300A, and it features a fully protected neutral pickup current of 1 times the rated current (Ir). The trip current rating stands at 25 AT, and all four poles are protected. The LV429056 employs an interchangeable thermal-magnetic (adjustable) trip unit type, ensuring comprehensive protection for electrical circuits.
Schneider Electric
Quick Quote
LV429055
Schneider Electric LV429055 is a 4-pole trip unit designed for thermal and magnetic protection. It falls under the TMD sub-range, functioning solely as a trip unit. This model offers thermal protection against overload and magnetic protection against short-circuits. It has a rated current of 32A, with over-current protection settings adjustable from 0.7 to 1.0 times the rated current (In). The short-circuit pickup current is fixed at 400A, and the fully protected neutral pickup current is set at 1 times the rated current (Ir). The LV429055 features a trip current rating of 32 AT and protects all 4 poles. Its trip unit type is TMD, which is interchangeable and thermal-magnetic adjustable.
Schneider Electric
Quick Quote
LV429054
Schneider Electric LV429054 is a 4-pole trip unit designed for thermal and magnetic protection. It falls under the TMD sub-range, functioning solely as a trip unit. This model offers thermal protection against overload and magnetic protection against short-circuits. It has a rated current of 40A, with over-current protection settings adjustable from 0.7 to 1.0 times the rated current (In). The short-circuit pickup current is fixed at 500A, and it features a fully protected neutral pickup current of 1 times the rated current (Ir). The trip current rating stands at 40 AT, and all four poles are protected. The LV429054 employs an interchangeable thermal-magnetic trip unit type that is adjustable, catering to a variety of protection needs.
Schneider Electric
Quick Quote
LV429053
Schneider Electric LV429053 is a 4-pole trip unit designed for thermal protection (overload) and magnetic protection (short-circuit). It falls under the sub-range name Trip unit (TMD) and functions as a trip unit alone. This part has a rated current of 50A and features protection settings that include over-current adjustable from 0.7 - 1.0 x In, with a short-circuit pickup current fixed at 500A and a fully protected neutral pickup current of 1 x Ir. The trip current rating is 50 AT, and all four poles are protected. The LV429053 employs a TMD interchangeable thermal-magnetic mechanism that is adjustable, catering to a variety of protection needs.
Schneider Electric
Quick Quote
LV429052
Schneider Electric LV429052 is a 4-pole trip unit designed for thermal and magnetic protection. It falls under the TMD sub-range, functioning solely as a trip unit. This model offers thermal protection against overload and magnetic protection against short-circuits. It has a rated current of 63A, with over-current protection settings adjustable from 0.7 to 1.0 times the rated current (In). The short-circuit pickup current is fixed at 500A, and the fully protected neutral pickup current is set at 1 times the rated current (Ir). The LV429052 features a trip current rating of 63 AT and protects all 4 poles. Its trip unit type is TMD, which is interchangeable and thermal-magnetic with adjustable settings.
Schneider Electric
Quick Quote
LV429051
Schneider Electric LV429051 is a 4-pole trip unit designed for thermal and magnetic protection. It falls under the TMD sub-range, functioning solely as a trip unit. This model offers thermal protection against overload and magnetic protection against short-circuits. It has a rated current of 80A, with over-current protection settings adjustable from 0.7 to 1.0 times the rated current (In). The short-circuit pickup current is fixed at 640A, and it features a fully protected neutral pickup current of 1 times the rated current (Ir). The LV429051 is equipped with an interchangeable thermal-magnetic trip unit type, ensuring adjustable protection for all 4 poles.
Schneider Electric
Quick Quote
LV429050
Schneider Electric LV429050 is a 4-pole trip unit designed for thermal and magnetic protection. It belongs to the TMD sub-range and functions as a trip unit alone. This part offers thermal protection against overload and magnetic protection against short-circuits. It has a rated current of 100A with over-current protection settings adjustable from 0.7 to 1.0 times the rated current (In). The short-circuit pickup current is fixed at 800A, and the fully protected neutral pickup current is set at 1 times the rated current (Ir). The LV429050 features a trip current rating of 100 AT and protects all 4 poles. Its trip unit type is TMD, which is interchangeable and thermal-magnetic adjustable.
Schneider Electric
Quick Quote