LZ1H2X4FU
Schneider Electric LZ1H2X4FU is a starter from the Hybrid sub-range designed for asynchronous motors, combining contact and zero-voltage triac technologies. It features screw connections and is a 3-pole (3P) device with thermal overload protection class 10A. The rated current is 2.4A for AC-51 and adjustable from 0.18A to 2.4A for AC-53a. This unit is suitable for DIN rail mounting and has an IP20 degree of protection. It operates with a control voltage of 110-230Vac (50Hz/60Hz) and a rated operating voltage (Ue) of up to 500 V. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, with a contacts type of SPDT / 1C/O. The rated impulse voltage (Uimp) is 6 kV. Its rated active power is 0.37kW at 220/230Vac, 0.75kW at 380/400Vac, 415Vac, and 440Vac, and 1.1kW at 500Vac for AC-53a. The rated power in horsepower (HP) is 0.5HP at 208Vac and 220-240Vac, and 1HP at 440-480Vac for a 3-phase system under UL standards.
Schneider Electric
Quick Quote
LZ7H2X43FU
Schneider Electric LZ7H2X43FU is a starter designed for asynchronous motors, belonging to the Hybrid sub-range, which combines contact and zero-voltage triac technologies. It features spring connections and is equipped with 3 poles (3P). The starter offers thermal overload protection classified under class 10A and supports a rated current of 2.4A for AC-51 and a range of 0.18A to 2.4A for AC-53a. It is designed for DIN rail mounting and has an IP20 degree of protection. The control voltage (AC) spans from 110 to 230Vac, compatible with both 50Hz and 60Hz frequencies, and it operates at a rated voltage (Ue) of up to 500 V. This unit includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, with a contact type of SPDT / 1C/O. The rated impulse voltage (Uimp) is 6 kV. It is capable of handling rated active power of 0.37kW at 220/230Vac, 0.75kW at 380/400Vac, 415Vac, and 440Vac, and 1.1kW at 500Vac, all under AC-53a conditions. Additionally, it supports rated power (HP) of 0.5HP at 208Vac and 220-240Vac, and 1HP at 440-480Vac, all for 3-phase connections under UL standards.
Schneider Electric
Quick Quote
LZ8H2X4FU
Schneider Electric LZ8H2X4FU is a starter designed for asynchronous motors, belonging to the Hybrid sub-range, which combines contact and zero-voltage triac technologies. It features screw connections and is equipped with 2 x 3-poles (2x3P) for connectivity. This ultra-compact hybrid reversing safety starter offers thermal overload protection of class 10A and supports a rated current range from 0.18A to 2.4A under AC-53a conditions. It is designed for DIN rail mounting and has an IP20 degree of protection. The control voltage ranges from 110 to 230Vac, compatible with both 50Hz and 60Hz frequencies, and it can operate at a rated operating voltage (Ue) of up to 500 V. The LZ8H2X4FU includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with a contacts type of SPDT / 1C/O contact. It has a rated impulse voltage (Uimp) of 6 kV and offers rated active power outputs of 0.37kW at 220/230Vac, 0.75kW at 380/400Vac, 415Vac, and 440Vac, and 1.1kW at 500Vac, all under AC-53a conditions. Additionally, it provides rated power in horsepower as 0.5HP at 208Vac and 220-240Vac, and 1HP at 440-480Vac, all for 3-phase applications according to UL standards.
Schneider Electric
Quick Quote
LC3D18AM7
Schneider Electric LC3D18AM7 is a plate-mounted motor starter from the Deca sub-range, designed for star-delta (Y-D / wye-delta) starting method. It features screw connections and is equipped with 3 x 3-poles (3x3P; 3x3NO) with a rated current of 32A (AC-1) and 18A (440Vac; AC-3). The starter offers plate mounting mode and has a degree of protection of IP20. The control voltage (AC) ranges from 176-242Vac (220Vac nominal; 50Hz; 0.8...1.1 x Uc) to 187-242Vac (220Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 0 Normally Open (NO) auxiliary contacts and 1 Normally Closed (NC) auxiliary contact, with the contacts type being 1NC aux. (KM1 star contactor). The rated impulse voltage (Uimp) is 6 kV, and the rated active power (kW) is 11kW (220/230Vac; AC-3), 18.5kW (380/400Vac; AC-3), 22kW (415Vac; AC-3), and 22kW (440Vac; AC-3). The rated voltage (AC) for phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC3D09AF7
Schneider Electric LC3D09AF7 is a plate-mounted motor starter from the Deca sub-range, designed for star-delta (Y-D / wye-delta) starting with screw connections. It features 3 x 3-poles (3x3P; 3x3NO) and is rated for currents of 25A (AC-1) and 9A (440Vac; AC-3). The starter offers plate mounting and an IP20 degree of protection. Control voltage ranges from 88-121Vac (110Vac nominal; 50Hz; 0.8...1.1 x Uc) to 93.5-121Vac (110Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 0 Normally Open (NO) auxiliary contacts and 1 Normally Closed (NC) auxiliary contact, with a contacts type of 1NC aux. (KM1 star contactor). The rated impulse voltage (Uimp) is 6 kV, and the rated active power (kW) spans 4kW at 220/230Vac (AC-3) up to 7.5kW at 440Vac (AC-3). The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC3D115M7A64
Schneider Electric LC3D115M7A64 is a plate-mounted motor starter from the Deca sub-range, featuring a mechanical interlock design and screw connections. It is equipped with 3 x 3-poles (3x3P; 3x3NO) and supports a rated current of 200A (AC-1) and 115A (440Vac; AC-3). The starter offers plate mounting and an IP20 degree of protection. It operates with a control voltage (AC) of 176-253Vac (220Vac nom.; 50Hz/60Hz; 0.8...1.15 x Uc) and a rated operating voltage (Ue) of 1000 V. This part includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, with a rated impulse voltage (Uimp) of 8 kV. The rated active power (kW) is 63kW (220/230Vac; AC-3), 110kW (380/400Vac; AC-3), 110kW (415Vac; AC-3), and 110kW (440Vac; AC-3), with contacts type of 1NC aux. (KM2 line contactor) and 1NO aux. (KM3 delta contactor). The rated voltage (AC) - Phase-to-phase is 1000 V.
Schneider Electric
Quick Quote
LC3D150F7
Schneider Electric LC3D150F7 is a plate-mounted motor starter from the Deca sub-range, designed for star-delta (Y-D / wye-delta) starting method. It features screw connections and is equipped with 3 x 3-poles (3x3P; 3x3NO) configuration. The starter has a rated current of 200A for AC-1 applications and 150A for 440Vac in AC-3 applications. It offers plate mounting mode and comes with an IP20 degree of protection. The control voltage (AC) ranges from 88-126Vac (110Vac nominal; 50Hz/60Hz; 0.8...1.15 x Uc), and it operates at a rated operating voltage (Ue) of 1000 V. This starter includes 1 Normally Open (NO) auxiliary contact and 2 Normally Closed (NC) auxiliary contacts, with a rated impulse voltage (Uimp) of 8 kV. The rated active power (kW) is 75kW at 220/230Vac, 132kW at 380/400Vac and 415Vac, and 147kW at 440Vac in AC-3 applications. The contacts type includes 1NC auxiliary for the KM1 star contactor, 1NC auxiliary for the KM2 line contactor, and 1NO auxiliary for the KM3 delta contactor. The rated voltage (AC) for phase-to-phase applications is 1000 V.
Schneider Electric
Quick Quote
LZ7H2X4FU
Schneider Electric LZ7H2X4FU is a starter designed for asynchronous motors, belonging to the Hybrid sub-range, which combines contact and zero-voltage triac technologies. It features screw connections and is equipped with 3 poles (3P). The starter offers thermal overload protection classified as class 10A and supports a rated current of 2.4A (AC-51) and 0.18A-2.4A (AC-53a). It is designed for DIN rail mounting and has an IP20 degree of protection. The control voltage (AC) ranges from 110-230Vac (50Hz/60Hz), with a rated operating voltage (Ue) of 500 V. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, with a contacts type of SPDT / 1C/O contact. The rated impulse voltage (Uimp) is 6 kV. The rated active power (kW) varies with voltage: 0.37kW at 220/230Vac, 0.75kW at 380/400Vac, 415Vac, and 440Vac, and 1.1kW at 500Vac, all under AC-53a conditions. The rated power (HP) is specified as 0.5HP (1/2HP) at 208Vac and 220-240Vac, and 1HP at 440-480Vac, all under AC-53a conditions and for 3-phase UL standards.
Schneider Electric
Quick Quote
LC3D18AQ7
Schneider Electric LC3D18AQ7 is a plate-mounted motor starter from the Deca sub-range, designed for star-delta (Y-D / wye-delta) starting method. It features screw connections and consists of 3 x 3-poles (3x3P; 3x3NO) with a rated current of 32A (AC-1) and 18A (440Vac; AC-3). The starter is designed for plate mounting and offers a degree of protection of IP20. It operates with a control voltage (AC) of 304-418Vac (380Vac nominal; 50Hz; 0.8...1.1 x Uc) and 323-418Vac (380Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. The LC3D18AQ7 has no Normally Open (NO) auxiliary contacts but includes 1 Normally Closed (NC) auxiliary contact (1NC aux. KM1 star contactor). It is rated for an impulse voltage (Uimp) of 6 kV and supports rated active power (kW) of 11kW (220/230Vac; AC-3), 18.5kW (380/400Vac; AC-3), 22kW (415Vac; AC-3), and 22kW (440Vac; AC-3). The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LZ8H2X43FU
Schneider Electric LZ8H2X43FU is a starter designed for asynchronous motors, belonging to the Hybrid sub-range. This ultra-compact hybrid reversing safety starter features a combination of contact and zero-voltage triac design. It offers spring connections and is equipped with 2 x 3-poles (2x3P) for connectivity. The LZ8H2X43FU provides thermal overload protection classified under class 10A and supports a rated current range from 0.18A to 2.4A (AC-53a). It is designed for DIN rail mounting and has an IP20 degree of protection. The control voltage (AC) spans from 110 to 230Vac (50Hz/60Hz), with a rated operating voltage (Ue) of up to 500 V. This starter includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both featuring SPDT / 1C/O contact type. The rated impulse voltage (Uimp) is 6 kV. It supports rated active power outputs of 0.37kW at 220/230Vac, 0.75kW at 380/400Vac, 415Vac, and 440Vac, and 1.1kW at 500Vac, all under AC-53a conditions. Additionally, it has a rated power in horsepower (HP) of 0.5HP at 208Vac and 220-240Vac, and 1HP at 440-480Vac, all for 3-phase connections under UL standards.
Schneider Electric
Quick Quote
LC3D150M7
Schneider Electric LC3D150M7 is a plate-mounted motor starter from the Deca sub-range, designed for star-delta (Y-D / wye-delta) starting method. It features screw connections and is equipped with 3 x 3-poles (3x3P; 3x3NO) configuration. The starter has a rated current of 200A for AC-1 applications and 150A for 440Vac in AC-3 applications. It is designed for plate mounting and offers a degree of protection of IP20. The control voltage (AC) ranges from 176-253Vac (220Vac nominal; 50Hz/60Hz; 0.8...1.15 x Uc). The rated operating voltage (Ue) is up to 1000 V, with a rated impulse voltage (Uimp) of 8 kV. It supports rated active power (kW) of 75kW at 220/230Vac, 132kW at 380/400Vac and 415Vac, and 147kW at 440Vac in AC-3 applications. The starter includes 1 Normally Open (NO) auxiliary contact and 2 Normally Closed (NC) auxiliary contacts, with contact types specified as 1NC aux. (KM1 star contactor), 1NC aux. (KM2 line contactor), and 1NO aux. (KM3 delta contactor). The rated voltage (AC) for phase-to-phase applications is 1000 V.
Schneider Electric
Quick Quote
LC3D115F7A64
Schneider Electric LC3D115F7A64 is a plate-mounted motor starter from the Deca sub-range, featuring a mechanical interlock design and screw connections. It is equipped with 3 x 3-poles (3x3P; 3x3NO) and supports a rated current of 200A (AC-1) and 115A (440Vac; AC-3). The starter is designed for plate mounting and offers a degree of protection of IP20. It operates with a control voltage (AC) of 88-126Vac (110Vac nominal; 50Hz/60Hz; 0.8...1.15 x Uc) and a rated operating voltage (Ue) of 1000 V. This part includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, with a rated impulse voltage (Uimp) of 8 kV. The rated active power (kW) is 63kW (220/230Vac; AC-3), 110kW (380/400Vac; AC-3), 110kW (415Vac; AC-3), and 110kW (440Vac; AC-3). The contacts type includes 1NC aux. (KM2 line contactor) and 1NO aux. (KM3 delta contactor), with a rated voltage (AC) - Phase-to-phase of 1000 V.