Filters
Manufacturer
Programmable Logic Controllers
part#
description
manufacturer
2819765
Inline measurement terminal for position encoder, complete with accessories, 1 input for incremental encoder with rectangular signal (symmetrical or asymmetrical), 3 digital inputs 24 V DC, 3-conductor connection method, transmission speed 2 Mbaud
Phoenix Contact
Quick Quote
2861548
Inline, Digital input terminal, Digital inputs: 1, 230 V AC, connection method: 3-conductor, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connector and labeling field
Phoenix Contact
Quick Quote
2862945
Inline, Digital output terminal, Digital outputs: 8, 24 V DC, 500 mA, connection method: 4-conductor, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connectors and marking fields, connectors numbered individual
Phoenix Contact
Quick Quote
2862178
Inline, Relay terminal, Relay output: 1 (floating contacts), 24 V DC, 230 V AC, for switching inductive and capacitive loads, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connector and labeling field
Phoenix Contact
Quick Quote
2700518
Axioline shield connection set (contains 2 shield bus holders and 2 SK 5 shield connection clamps)
Phoenix Contact
Quick Quote
1052428
Axioline P bus base module for housing type F2
Phoenix Contact
Quick Quote
2316396
Axioline P bus base module for housing type FBPS base
Phoenix Contact
Quick Quote
2916930
Connector set (yellow), color coded, for safe SDI boards.
Phoenix Contact
Quick Quote
2878243
Inline, Digital input terminal, Digital inputs: 32 (NPN), 24 V DC, connection method: 1-conductor, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connectors and marking fields
Phoenix Contact
Quick Quote
2861438
Inline power terminal block, complete with accessories (connector and labeling field), 24 V DC, with fuse (Main voltage)
Phoenix Contact
Quick Quote
2701155
Inline XC, Digital output terminal, Digital outputs: 4, 24 V DC, 500 mA, connection method: 3-conductor, Extreme conditions version, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connector and labeling field
Phoenix Contact
Quick Quote
2878159
INTERBUS FO branch terminal block, without accessories, transmission speed 2 Mbaud, with remote bus branch, 24 V DC
Phoenix Contact
Quick Quote
2701152
Inline XC, Digital input terminal, Digital inputs: 4, 24 V DC, connection method: 3-conductor, Extreme conditions version, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connector and labeling field
Phoenix Contact
Quick Quote
2701161
Inline power terminal, version for extreme conditions, complete with accessories (connector and labeling field), 24 V DC, without fuse
Phoenix Contact
Quick Quote
2701219
Inline XC, Analog output terminal, Analog output: 1, 0 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, connection method: 2-conductor, transmission speed in the local bus: 500 kbps, Extreme conditions version, degree of protection: IP20, including Inline conn
Phoenix Contact
Quick Quote
2701215
Inline XC, Analog input terminal, Analog inputs: 4, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection method: 2-, 3-, 4-conductor, transmission speed in the local bus: 500 kbps, Extreme c
Phoenix Contact
Quick Quote
2701216
Inline XC, Temperature measurement terminal, Analog UTH inputs: 2 (Thermocouples or linear voltage), connection method: 2-conductor, transmission speed in the local bus: 500 kbps, Extreme conditions version, degree of protection: IP20, including Inline co
Phoenix Contact
Quick Quote
2773555
The space-saving local bus device is particularly suitable for use in close proximity to the process. Functions: 2 Mbaud, 8 digital inputs with 3 ms filter time, channel-specific diagnostics, short-circuit/overload protection, 600 mA nominal current, M8 c
Phoenix Contact
Quick Quote
2736835
The local bus device has digital inputs. Functions: 16 digital inputs, 3 ms filter time, 500 kbaud/2 Mbaud selection, channel-specific diagnostics, short-circuit and overload protection, 1.2 A nominal current, M12 fast connection technology.
Phoenix Contact
Quick Quote
2736961
Adapter for connecting Fieldline Modular M8 devices to a Fieldline Modular M12 local bus
Phoenix Contact
Quick Quote
Items per page:
Programmable Logic Controllers
General Guide & Overview
Programmable Logic Controllers (PLCs) are digital computers used in industrial organizations to control computer systems. They monitor inputs and make decisions about related outputs, making them an essential component in predictive maintenance systems. PLCs have a rich history, with the first one being developed by Dick Morley in 1968. Over the years, PLC technology has evolved, from physical relays and timers to PC-based software.
PLCs can be classified into different types, such as PLCs, PACs, SCADA, DCS, and DDC, each serving specific automation needs. They consist of key components, including inputs, outputs, CPUs, communications, and HMIs. PLCs operate through a scan cycle, continuously monitoring inputs, executing control programs, and controlling outputs.
Different programming languages, such as ladder logic, structured text, instruction list, function block diagram, and sequential function chart, are used to program PLCs. Compact and modular PLCs offer flexibility and scalability. PLC maintenance is essential for optimal performance, with tasks such as cleaning dust, replacing modules, and checking connections.
Types and Components of PLCs
Programmable Logic Controllers (PLCs) come in various types, each designed to meet specific automation needs. Two main types of PLCs are compact PLCs and modular PLCs. Compact PLCs are integrated single-unit systems with the processor, power supply, and I/O modules all housed together. They are ideal for smaller applications due to their smaller physical footprint. On the other hand, modular PLCs offer flexibility and scalability, allowing for easier system expansion. They are often preferred by larger or growing companies that require more extensive control.
A PLC consists of several critical components that work together to perform its function. These components include inputs, outputs, CPUs, and communication capabilities. Inputs are connected to sensors and devices to gather data and information. The gathered data is then processed by the CPU, the brain of the PLC, which evaluates and makes decisions based on the input. The output devices, connected to outputs, control various components such as valves and motors to execute the desired actions.
PLCs also have communication capabilities, enabling integration with other devices and systems in the industrial environment. This ensures seamless coordination and interaction between different elements of the automation system. PLCs are an essential part of automation systems, providing reliable control and efficient operation across various industries.
PLC Maintenance Best Practices
Proper PLC maintenance is crucial for ensuring optimal performance and minimizing breakdowns. By following a comprehensive PLC maintenance checklist, you can keep your system running smoothly and prevent costly downtime.
Here are some important PLC maintenance tasks:
Cleaning dust from input and output devices to prevent signal interference and component failure.
Changing filters regularly to control dust accumulation and maintain proper ventilation within the PLC system.
Inspecting connections for secureness to avoid loose connections that can disrupt communication and reduce reliability.
Replacing worn-out modules to prevent malfunctions and ensure accurate processing of data and commands.
Increasing awareness of unusual activity by monitoring error logs and system performance to identify potential issues before they escalate.
Backing up PLC data regularly to protect against data loss in the event of a system failure or unexpected event.
Monitoring environmental conditions such as temperature and humidity to ensure they are within the specified operating range.
Calibrating devices periodically to maintain accurate measurements and prevent deviations that can impact system performance.
Conducting visual inspections of the PLC system to identify any physical damage, loose connections, or signs of wear and tear.
Checking LED lights for proper functionality, as they provide valuable diagnostic information.
Inspecting sensors to ensure they are clean, properly aligned, and functioning correctly, as they are critical for accurate data acquisition.
Addressing electromagnetic interference by keeping sensitive components and wiring away from sources of electromagnetic radiation.
Reviewing the proximity of equipment to identify potential interference and ensure proper positioning for efficient operation.
Keeping the PLC system up to date with recalls and upgrades to benefit from the latest software patches, enhancements, and security updates.
The frequency of maintenance tasks may vary depending on factors such as the surrounding environment, machine usage, and available maintenance staff capacity. It is recommended to perform daily tasks such as dusting and tidying, while more specific tasks can be scheduled at regular intervals or based on manufacturer recommendations.
FAQ
What is a programmable logic controller (PLC)?
A programmable logic controller (PLC) is a digital computer used in industrial organizations to control computer systems. It monitors inputs and makes decisions about related outputs, making it an essential component in predictive maintenance systems.
Who invented the first PLC?
The first PLC was developed by Dick Morley in 1968.
How do PLCs work?
PLCs operate through a scan cycle, continuously monitoring inputs, executing control programs, and controlling outputs.
What are the different types of PLCs?
PLCs can be classified into types such as PLCs, PACs, SCADA, DCS, and DDC, each serving specific automation needs.
What are the key components of a PLC?
The key components of a PLC include inputs, outputs, CPUs, communications, and HMIs.
What programming languages are used for PLCs?
Different programming languages, such as ladder logic, structured text, instruction list, function block diagram, and sequential function chart, are used to program PLCs.
What are the advantages of PLCs?
PLCs offer advantages such as flexibility, scalability, easy expansion, integration with other devices and systems, and improved processing speeds.
Where are PLCs used?
PLCs are used in various industries, including manufacturing, automation, oil and gas, energy, and transportation.
How important is PLC maintenance?
PLC maintenance is crucial for ensuring optimal performance and avoiding breakdowns. Regular tasks include cleaning dust, replacing modules, and checking connections.