Filters
Manufacturer
Programmable Logic Controllers
part#
description
manufacturer
NX102-9000
NX102-9000, Machine Automation Controller, Communication ports: EtherCAT and 2x EtherNet/IP built in, Flash memory port: SD, I/O capacity: 1024 Points local (8960 with NX Coupler)
Omron
STOCK: 78
Fast shipping1052417
Axioline P EX, Digital input module, Digital inputs: 16 (NAMUR), 8 V DC, connection method: 2-conductor, Intrinsically safe, transmission speed in the local bus: 100 Mbps, degree of protection: IP20
Phoenix Contact
STOCK: 14
Fast shipping1086902
Axioline F XC, Digital output module, Digital outputs: 4, 21 V, 60 mA, connection method: 3-conductor, Extreme conditions version, Intrinsically safe, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and
Phoenix Contact
STOCK: 14
Fast shipping2701492
Axioline E, Digital I/O device, EtherNet/IP™, M12 fast connection technology, Digital inputs:, 24 V DC, connection method: 4-conductor, Digital outputs: , 500 mA, connection method: 3-conductor, Plastic housing, degree of protection: IP65/IP67
Phoenix Contact
STOCK: 13
Fast shipping2897156
Inline, Digital input terminal, Digital inputs: 16, 24 V DC, connection method: 3-conductor, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connectors and marking fields
Phoenix Contact
STOCK: 2
Fast shipping1079231
Axioline Smart Elements, Digital output module, PROFIsafe, Safe digital outputs: 4 (1-channel assignment), 2 (2-channel assignment), 24 V DC, 2 A, connection method: 2-conductor, degree of protection: IP20
Phoenix Contact
STOCK: 13
Fast shipping2688297
Axioline F, Power module for the logic supply UBus, max. 4 A, degree of protection: IP20, including bus base module and Axioline F connector
Phoenix Contact
STOCK: 9
Fast shipping2404201
Emalytics Controller license for an additional 1250 data points (with initial purchase of the license)
Phoenix Contact
STOCK: 12
Fast shipping2861878
Inline, Relay terminal, Relay outputs: 4 (floating contacts), 24 V DC, 230 V AC, for switching ohmic loads, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connectors and marking fields
Phoenix Contact
STOCK: 9
Fast shipping2403160
The modular Inline controller for automation applications in buildings, infrastructure, and energy for connection with standard automation technology with the Internet of Things (IoT). The controller makes it possible to implement complex systems efficien
Phoenix Contact
STOCK: 21
Fast shipping2701228
Axioline F XC, Digital output module, Digital outputs: 16, 24 V DC, 500 mA, connection method: 3-conductor, Extreme conditions version, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F con
Phoenix Contact
STOCK: 12
Fast shipping1132800
Axioline P bus coupler for PROFINET. Connects to Axioline P I/O modules along the AXIOLINE P local bus. (includes power supply connector and bus base module)
Phoenix Contact
STOCK: 1
Fast shipping1052431
Axioline P EX, Analog input module, Analog inputs: 8, 4 mA ... 20 mA, connection method: 2-conductor, transmission speed in the local bus: 100 Mbps, HART functionality, Intrinsically safe, degree of protection: IP20
Phoenix Contact
STOCK: 11
Fast shipping2861373
Inline segment terminal, complete with accessories (connector and labeling field), 24 V DC, with fuse
Phoenix Contact
STOCK: 10
Fast shipping2861768
Inline measurement terminal block for position encoder, complete with accessories (connector and labeling field), 1 input for inductive length measuring scales with the impulse interface (P interface)
Phoenix Contact
STOCK: 10
Fast shipping6ES71426BF000AB0
SIMATIC DP, ET 200ECO PN, 8 DO 24 V DC/1.3 A; 4xM12, Duplicate assignment, Degree of protection IP67
Siemens
STOCK: 10
Fast shipping1185423
PLCnext Industrial Edge Computer with Intel® Celeron® N3350 processor. This small form factor programmable edge device supports IEC61131-3, MATLAB Simulink, C/C++, and is perfect for protocol converting, data collection, and cloud computing.
Phoenix Contact
STOCK: 10
Fast shipping2702291
Axioline F, Digital I/O module, Digital inputs: 16, 24 V DC, connection method: 1-conductor, Digital outputs: 8, 24 V DC, 2 A, connection method: 2-conductor, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base mo
Phoenix Contact
STOCK: 10
Fast shippingCJ1W-PA205R
CJ1W-PA205R, PLC - Power Supply Units, Supply voltage: 100 to 240 VAC, Power rating: 25 W, Built-in maintenance tools: Run-time display, relay output
Omron
STOCK: 6
Fast shipping2701722
Axioline F, Digital input module, Digital inputs: 16, 24 V DC, connection method: 1-conductor, Input filter time < 5 µs, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
Phoenix Contact
STOCK: 9
Fast shipping
Items per page:
Programmable Logic Controllers
General Guide & Overview
Programmable Logic Controllers (PLCs) are digital computers used in industrial organizations to control computer systems. They monitor inputs and make decisions about related outputs, making them an essential component in predictive maintenance systems. PLCs have a rich history, with the first one being developed by Dick Morley in 1968. Over the years, PLC technology has evolved, from physical relays and timers to PC-based software.
PLCs can be classified into different types, such as PLCs, PACs, SCADA, DCS, and DDC, each serving specific automation needs. They consist of key components, including inputs, outputs, CPUs, communications, and HMIs. PLCs operate through a scan cycle, continuously monitoring inputs, executing control programs, and controlling outputs.
Different programming languages, such as ladder logic, structured text, instruction list, function block diagram, and sequential function chart, are used to program PLCs. Compact and modular PLCs offer flexibility and scalability. PLC maintenance is essential for optimal performance, with tasks such as cleaning dust, replacing modules, and checking connections.
Types and Components of PLCs
Programmable Logic Controllers (PLCs) come in various types, each designed to meet specific automation needs. Two main types of PLCs are compact PLCs and modular PLCs. Compact PLCs are integrated single-unit systems with the processor, power supply, and I/O modules all housed together. They are ideal for smaller applications due to their smaller physical footprint. On the other hand, modular PLCs offer flexibility and scalability, allowing for easier system expansion. They are often preferred by larger or growing companies that require more extensive control.
A PLC consists of several critical components that work together to perform its function. These components include inputs, outputs, CPUs, and communication capabilities. Inputs are connected to sensors and devices to gather data and information. The gathered data is then processed by the CPU, the brain of the PLC, which evaluates and makes decisions based on the input. The output devices, connected to outputs, control various components such as valves and motors to execute the desired actions.
PLCs also have communication capabilities, enabling integration with other devices and systems in the industrial environment. This ensures seamless coordination and interaction between different elements of the automation system. PLCs are an essential part of automation systems, providing reliable control and efficient operation across various industries.
PLC Maintenance Best Practices
Proper PLC maintenance is crucial for ensuring optimal performance and minimizing breakdowns. By following a comprehensive PLC maintenance checklist, you can keep your system running smoothly and prevent costly downtime.
Here are some important PLC maintenance tasks:
Cleaning dust from input and output devices to prevent signal interference and component failure.
Changing filters regularly to control dust accumulation and maintain proper ventilation within the PLC system.
Inspecting connections for secureness to avoid loose connections that can disrupt communication and reduce reliability.
Replacing worn-out modules to prevent malfunctions and ensure accurate processing of data and commands.
Increasing awareness of unusual activity by monitoring error logs and system performance to identify potential issues before they escalate.
Backing up PLC data regularly to protect against data loss in the event of a system failure or unexpected event.
Monitoring environmental conditions such as temperature and humidity to ensure they are within the specified operating range.
Calibrating devices periodically to maintain accurate measurements and prevent deviations that can impact system performance.
Conducting visual inspections of the PLC system to identify any physical damage, loose connections, or signs of wear and tear.
Checking LED lights for proper functionality, as they provide valuable diagnostic information.
Inspecting sensors to ensure they are clean, properly aligned, and functioning correctly, as they are critical for accurate data acquisition.
Addressing electromagnetic interference by keeping sensitive components and wiring away from sources of electromagnetic radiation.
Reviewing the proximity of equipment to identify potential interference and ensure proper positioning for efficient operation.
Keeping the PLC system up to date with recalls and upgrades to benefit from the latest software patches, enhancements, and security updates.
The frequency of maintenance tasks may vary depending on factors such as the surrounding environment, machine usage, and available maintenance staff capacity. It is recommended to perform daily tasks such as dusting and tidying, while more specific tasks can be scheduled at regular intervals or based on manufacturer recommendations.
FAQ
What is a programmable logic controller (PLC)?
A programmable logic controller (PLC) is a digital computer used in industrial organizations to control computer systems. It monitors inputs and makes decisions about related outputs, making it an essential component in predictive maintenance systems.
Who invented the first PLC?
The first PLC was developed by Dick Morley in 1968.
How do PLCs work?
PLCs operate through a scan cycle, continuously monitoring inputs, executing control programs, and controlling outputs.
What are the different types of PLCs?
PLCs can be classified into types such as PLCs, PACs, SCADA, DCS, and DDC, each serving specific automation needs.
What are the key components of a PLC?
The key components of a PLC include inputs, outputs, CPUs, communications, and HMIs.
What programming languages are used for PLCs?
Different programming languages, such as ladder logic, structured text, instruction list, function block diagram, and sequential function chart, are used to program PLCs.
What are the advantages of PLCs?
PLCs offer advantages such as flexibility, scalability, easy expansion, integration with other devices and systems, and improved processing speeds.
Where are PLCs used?
PLCs are used in various industries, including manufacturing, automation, oil and gas, energy, and transportation.
How important is PLC maintenance?
PLC maintenance is crucial for ensuring optimal performance and avoiding breakdowns. Regular tasks include cleaning dust, replacing modules, and checking connections.