Filters
Manufacturer
Redundancy Modules
part#
description
manufacturer
YR40.482
PULS YR40.482 is a redundancy unit belonging to the Y-series, designed with a built-in decoupling MOSFET for 1+1 or N+1 redundancy configurations and ATEX approval. It operates with a supply voltage range of 20.4Vdc to 64.4Vdc, supporting nominal voltages of 24Vdc, 48Vdc, and 60Vdc. The unit measures 46mm in width, 124mm in height, and 127mm in depth, featuring screw-clamp connections for secure installation. It is rated for a current of 40A at 56Vdc, with a derating to 1A at temperatures ranging from +60°C to +70°C. Designed for DIN rail mounting, it can function within an ambient air temperature range of -40°C to +70°C. The YR40.482 has a peak inrush current consumption of 1000A and offers protection functions including short-circuit protection with a 45A threshold at 6V. It supports both series and parallel operation for 1+1 and N+1 redundancy, ensuring continuous operation by using two or more identical power supplies in parallel. The output voltage range is 24-56Vdc, with power dissipation/losses of 1.8W for 2x10A input and 2.3W for 20A input. Its electrical durability is rated at 448000 hours at 40°C for 20A output with 2x10A input and 222000 hours for 40A output with 2x20A input. At 25°C, durability extends to 1267000 hours for 20A output with 2x10A input and 629000 hours for 40A output with 2x20A input. The output stage capacitance is 310 µF, with a ripple of 60mVpp across a frequency range of 20Hz to 20MHz at 50Ω.
Puls
Quick Quote
SLR01
Redundancy Module, 24-28VDC, 40A, Single Input
Puls
Quick Quote
SLR5.100
Redundancy Power Supply, 120W, 100-120 / 200-240VAC 1PH, 24VDC, 5A
Puls
Quick Quote
MLY02.100
PULS MLY02.100 is a redundancy unit featuring a dual-input redundancy module with 2 inputs and 1 output, designed for DIN rail mounting. It operates within an ambient air temperature range of -40 to +70°C using diode technology. The unit has a rated current of 10A at 48Vdc, with a derating to 0.25A for temperatures between +60°C and +70°C. Connection is facilitated through spring-clamp connections. The dimensions of the MLY02.100 are 45mm in width, 75mm in height, and 91mm in depth. It supports a supply voltage range from 9Vdc to 60Vdc, accommodating 12Vdc, 24Vdc, and 48Vdc systems, with an output voltage range of 12-48Vdc. The unit is equipped with short-circuit protection, featuring a 16A threshold at 6V. Power dissipation at nominal load is 4W, and it boasts an electrical durability of a minimum of 218,000 hours at +40°C. Ripple is specified at 800mVpp over a frequency range of 20Hz to 20MHz at 50Ω.
Puls
Quick Quote
YR80.242
PULS YR80.242 is a redundancy unit from the Y-series designed with a built-in decoupling MOSFET for 1+1 or N+1 redundancy and ATEX approval. It operates with a supply voltage range of 8.4Vdc to 36.4Vdc, supporting nominal voltages of 12Vdc and 24Vdc. The unit measures 46mm in width, 124mm in height, and 127mm in depth, featuring screw-clamp connections for secure installation. It is rated for a current of 80A at 28Vdc, with a derating to 2A at temperatures ranging from +60°C to +70°C. Designed for DIN rail mounting, it can operate within an ambient air temperature range of -40°C to +70°C. The YR80.242 has a peak inrush current consumption of 1500A and offers protection functions including short-circuit protection with a 44A threshold at 6V. It supports series or parallel operation for 1+1 redundancy, utilizing two identical power supplies, or N+1 redundancy with three or more power supplies, ensuring continued operation following most single power supply failures. The output voltage is maintained between 12-28Vdc, with power dissipation/losses of 2.9W for 2x20A input and 4.6W for 40A input at 8.4-36.4Vdc. Its electrical durability is rated at 499,000 hours at 40°C with a 40A output from 2x20A input, and 1,410,000 hours at 25°C with an 80A output from 2x20A input. The output stage capacitance is 320µF, with a ripple of 65mVpp across a frequency range of 20Hz to 20MHz at 50Ω.
Puls
Quick Quote
YR20.246
PULS YR20.246 is a redundancy unit from the Y-series designed for dual-input redundancy (2 x inputs + 1 x output) with a built-in decoupling MOSFET, suitable for 1+1 or N+1 redundancy configurations and has ATEX approval. It operates with a supply voltage range of 18Vdc-35Vdc (24Vdc nominal) and supports a rated current of 20A at 48Vdc. The unit features screw-clamp connections for secure installation and is designed for DIN rail mounting. It can operate within an ambient air temperature range of -40 to +70°C. The dimensions of the unit are W32mm x H124mm x D117mm. It includes protection functions against short-circuits, with a threshold of 26A at 6V, and supports series or parallel operation for redundancy. The output voltage range is 24-48Vdc (24Vdc / 48Vdc nominal), with power dissipation/losses varying between 2.6 W and 5.6 W depending on the input conditions. The electrical durability of the unit ranges from 182,000 to 1,053,000 hours, depending on the operating conditions. The output stage capacitance is 320 µF, and the ripple is specified as 100-500mVpp (20Hz...20MHz; 50Ω).
Puls
Quick Quote
DRDN20-48
20A DIN rail Redundancy Module to improve overall system operation reliability; Support 1+1 and N+1 redundancy system; 2 channels input and 1 output; DC OK; Input 48Vdc
MEAN WELL
Quick Quote
ERDN40-48
40A Enclosed Redundancy Module to improve overall system operation reliability; Support 1+1 and N+1 redundancy system; 2 channels input and 1 output; DC OK; Input 48Vdc
MEAN WELL
Quick Quote
S8VK-R10
S8VK-R Redundancy Unit
Omron
Quick Quote
Items per page: