Filters
Manufacturer
More in this category
Thermal Overload Relays
part#
description
manufacturer
CT7N-23-C12
Sprecher + Schuh CT7N-23-C12 - CT7N Thermal Bimetalic Overload Relay, Direct Mount for CA7-9 to 23, Auto or Manual Reset, 9.0-12.5 Amps, 1 or 3-Phase, Class 10
Sprecher + Schuh
Quick Quote
CT7N-85-C60P
Sprecher + Schuh CT7N-85-C60P - CT7N Thermal Bimetalic Overload Relay, Separate Mount, Auto or Manual Reset, 45-60 Amps, 1 or 3-Phase, Class 10
Sprecher + Schuh
Quick Quote
CEP7-1EFFP
Sprecher + Schuh CEP7-1EFFP - CEP7 Solid State Overload Relay, Pass-thru, Auto or Manual Reset, 11-55 Amps, 1 or 3-Phase, Class 10/15/20/30
Sprecher + Schuh
Quick Quote
CEP7-1EFGE
Sprecher + Schuh CEP7-1EFGE - CEP7 Solid State Overload Relay, Direct Mount for CA7-60 to 97, Auto or Manual Reset, 20-100 Amps, 1 or 3-Phase, Class 10/15/20/30
Sprecher + Schuh
Quick Quote
CEP7-1EFLZ
Sprecher + Schuh CEP7-1EFLZ - CEP7 Solid State Overload Relay, Pass-thru, Auto or Manual Reset, 100...500 Amps, 1 or 3-Phase, Class 10/15/20/30
Sprecher + Schuh
Quick Quote
CEP7-1EFCB
Sprecher + Schuh CEP7-1EFCB - CEP7 Solid State Overload Relay, Direct Mount for CA7-9 to 16, Auto or Manual Reset, 1.0-5.0 Amps, 1 or 3-Phase, Class 10/15/20/30
Sprecher + Schuh
Quick Quote
CT7N-85-C47P
Sprecher + Schuh CT7N-85-C47P - CT7N Thermal Bimetalic Overload Relay, Separate Mount, Auto or Manual Reset, 35-47 Amps, 1 or 3-Phase, Class 10
Sprecher + Schuh
Quick Quote
CT7N-23-B25
Sprecher + Schuh CT7N-23-B25 - CT7N Thermal Bimetalic Overload Relay, Direct Mount for CA7-9 to 23, Auto or Manual Reset, 1.8-2.5 Amps, 1 or 3-Phase, Class 10
Sprecher + Schuh
Quick Quote
CT7N-23-B48
Sprecher + Schuh CT7N-23-B48 - CT7N Thermal Bimetalic Overload Relay, Direct Mount for CA7-9 to 23, Auto or Manual Reset, 3.5-4.8 Amps, 1 or 3-Phase, Class 10
Sprecher + Schuh
Quick Quote
LRD3323
Schneider Electric LRD3323 is a differential thermal overload relay designed for direct connection to a contactor and features spring-type fast connections for both upstream and outgoing cables, as well as the control circuit. This 3-pole device offers protection functions classified under Class 10A, with a rated current range of 23-32 A. It includes protection settings for thermal overload within the same range. The LRD3323 is equipped with 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. It supports a rated voltage (AC) phase-to-phase of up to 690 V at frequencies ranging from 0 to 400Hz. The minimum operating current is 23 A, and the maximum current capacity is 32 A.
Schneider Electric
Quick Quote
LT4760M7S
Schneider Electric LT4760M7S, part of the LT47 sub-range, is a 3-pole electronic overcurrent relay designed for use with 2 measurement current transformers in a control circuit featuring screw-clamp connections. It offers protection functions including electronic overcurrent relay, locked rotor mechanical jamming, overload with Imax greater than Isetting, and sensitivity to phase failure. The rated current range is 5-60 A, with control voltage specifications of 200-240 Vdc for DC and 200-240 Vac (50/60Hz) for AC. Protection settings include thermal overload adjustments from 5-60A, a D-time knob ranging from 0.5-30s, and an O-time knob from 0.3-10s. It also features 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The supply voltage is rated at 200-240 V for both AC and DC, with a rated voltage (AC) phase-to-phase of 690 V (50-60Hz). The minimum and maximum currents are set at 5 A and 60 A, respectively.
Schneider Electric
Quick Quote
LR97D015B
Schneider Electric LR97D015B is a 3-pole electronic overcurrent relay designed for direct connection to a contactor with outgoing cables and control circuits connected via screw-clamp. It features protection functions including electronic overcurrent relay, locked rotor mechanical jamming, overload with Imax greater than Isetting, and sensitivity to phase failure. The rated current range is 0.3-1.5 A, with protection settings for thermal overload adjustable between 0.3-1.5A, a D-time knob setting range of 0.5-30s, and an O-time knob setting range of 0.3-10s. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The supply voltage is 24 V AC/DC, with a rated voltage for phase-to-phase connections at 690 V AC (50-60Hz). The minimum current capability is 0.3 A, and the maximum current capability is 1.5 A.
Schneider Electric
Quick Quote
LRD350L6
Schneider Electric LRD350L6 is a differential thermal overload relay within the LRD sub-range, designed for direct connection to a contactor and equipped with lugs for outgoing cables in the control circuit. This 3-pole device features screw-clamp connections and offers protection functions classified as Class 20. It operates within a rated current range of 37-50 A, with protection settings specifically for thermal overload between 37-50A. The LRD350L6 includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. It is rated for a voltage of up to 690 V AC (0-400Hz) across phases, with a minimum operating current of 37 A and a maximum of 50 A.
Schneider Electric
Quick Quote
LRD3253
Schneider Electric LRD3253 is a differential thermal overload relay belonging to the LRD sub-range. It features a 3-pole configuration and offers direct connection to a contactor for upstream connections, with outgoing cables and control circuit connections utilizing spring-type fast connections. This relay is designed for a rated current of 17-25 A and operates within a protection setting range of 17-25A for thermal overload. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The LRD3253 is capable of handling a rated voltage (AC) of up to 690 V at frequencies ranging from 0 to 400Hz. Its operational current range is specified from a minimum of 17 A to a maximum of 25 A, and it is classified under protection class 10A.
Schneider Electric
Quick Quote
LRD3133
Schneider Electric LRD3133 is a differential thermal overload relay designed for direct connection to a contactor with spring-type fast connections for both upstream and outgoing cables, as well as the control circuit. It features 3 poles and offers protection functions classified under Class 10A. The LRD3133 operates within a rated current range of 9-13 A, with protection settings specifically for thermal overload between 9-13A. It is equipped with 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The rated voltage for phase-to-phase connections is up to 690 V, accommodating frequencies from 0 to 400Hz. The minimum operating current is set at 9 A, with a maximum threshold of 13 A.
Schneider Electric
Quick Quote
LRD14L6
Schneider Electric LRD14L6 is a differential thermal overload relay designed for direct connection to a contactor, with outgoing cables connected via lugs and a control circuit utilizing screw-clamp connections. This 3-pole device offers protection functions classified under Class 20, with a rated current range of 7-10 A. It features protection settings for thermal overload within the same range (7-10A) and includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The rated voltage for phase-to-phase operation is up to 690 V (0-400Hz), with a minimum operating current of 7 A and a maximum of 10 A.
Schneider Electric
Quick Quote
LR7K0312
Schneider Electric LR7K0312 is a non-differential thermal overload relay designed for unbalanced networks, belonging to the LR7K sub-range. It features a 3-pole configuration and offers protection functions classified under Class 10A. The relay supports a rated current range of 3.7-5.5 A with protection settings adjustable within the same range. Connection types include direct to contactor for upstream connections and screw-clamp terminals for both outgoing cables and the control circuit. It is equipped with 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The rated voltage for phase-to-phase connections is up to 690 V, with the minimum and maximum current settings specified at 3.7 A and 5.5 A, respectively.
Schneider Electric
Quick Quote
LR3D32L6
Schneider Electric LR3D32L6 is a non-differential thermal overload relay designed for unbalanced networks, falling within the LR3D sub-range. It features a direct connection to the contactor for upstream connections, with outgoing cables connected via lugs and a control circuit utilizing screw-clamp connections. This 3-pole relay is engineered for a rated current of 23-32 A, with protection settings adjustable within the same range. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts for enhanced functionality. The LR3D32L6 is capable of handling a phase-to-phase rated voltage (AC) of up to 690 V at frequencies ranging from 0 to 400Hz, with a minimum operating current of 23 A and a maximum of 32 A.
Schneider Electric
Quick Quote
LR3D10L6
Schneider Electric LR3D10L6 is a non-differential thermal overload relay designed for unbalanced networks, belonging to the LR3D sub-range. It features a 3-pole configuration and offers protection functions with a class 20 rating. The relay is designed for direct connection to a contactor upstream, with outgoing cables connected to lugs and a control circuit connected via screw-clamp terminals. It supports a rated current range of 4-6 A, with protection settings adjustable within the same range. The LR3D10L6 includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts for enhanced control functionality. It is capable of handling a rated voltage (AC) of up to 690 V at frequencies ranging from 0 to 400Hz, with a minimum operating current of 4 A and a maximum of 6 A.
Schneider Electric
Quick Quote
LRD365L3
Schneider Electric LRD365L3 is a differential thermal overload relay belonging to the LRD sub-range. It features a 3 Pole configuration and offers protection functions specifically designed for Class 20 applications. The relay supports a rated current range of 48-65 A with protection settings for thermal overload within the same range. Connection types include direct to contactor for upstream connections and spring-type fast connections for both outgoing cables and the control circuit. It is equipped with 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The rated voltage for phase-to-phase connections is up to 690 V (0-400Hz), with a minimum operating current of 48 A and a maximum of 65 A.
Schneider Electric
Quick Quote
Items per page: