1088104 Phoenix Contact Programmable Logic Controllers
Part#:1088104
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 15
Dec 22, 2024
Axioline Smart Elements, Analog input module, Analog inputs: 4, 0 V ... 10 V, connection method: 2-conductor, degree of protection: IP20
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1088104 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Conductor cross section flexible min. 0.25 mm²
- Stripping length 8 mm
- Degree of pollution 2 (EN 60664-1)
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (operation) -25 °C ... 60 °C
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Conductor cross section AWG min. 24
- Mounting type Smart Element slot
- Start time until ready to operate < 1000 ms (after switching on the supply voltage (object 003Dhex: WakeUpTime))
- Supply voltage 24 V DC (using card edge connectors)
- Input name Analog inputs
- Type of protection Transient protection
- Measured value representation 16 bits
- Height 62.2 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline Smart Elements” user manual.
- Caption Dimensions
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Connection method Push-in technology
- Conductor cross section, flexible, with ferrule, with plastic sleeve 0.25 mm² ... 1.5 mm²
- Net weight 35 g
- Transmission speed See system in which you use the Smart Element.
- Protective circuit Surge protection See the system in which the Smart Element is used.
- Note regarding the connection technology shielded, twisted pair
- A/D converter resolution 12 bit
- Input resistance of voltage input > 100 kΩ
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, 2 kV
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 27242601
- Width 14.9 mm
- Number 1
- Mounting position See the system in which the Smart Element is used.
- Protection See the system in which the Smart Element is used.
- Power consumption min. 288 mW
- Connection technology 2-conductor
- Test section Communications supply / 24 V supply (I/O) 500 V AC 50 Hz 1 min.
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Designation I/O supply (UP)
- Conductor cross section flexible max. 1.5 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve 0.25 mm² ... 1.5 mm²
- Depth 62 mm
- Degree of protection IP20
- Conductor cross section solid max. 1.5 mm²
- Conductor cross section solid min. 0.25 mm²
- Conductor cross section AWG max. 16
- Color traffic grey A RAL 7042
- Additional text using card edge connectors
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Number of inputs 4
- Data formats Standardized representation
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Overvoltage category II (IEC 60664-1)
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ECLASS 9.0 27242601
- Current consumption min. 12 mA (without connected peripherals)
- Description of the input Single-ended inputs, voltage
- Voltage input signal 0 V ... 10 V
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- China RoHS Environmentally Friendly Use Period = 50 years
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, shielded I/O cables: ±1 kV asymmetrical
- ECLASS 10.0.1 27242601
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 5 days!
1-year warranty
$115.10
Stock:
15
Select Qty:
$115.10
$115.10 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨