3002617 Phoenix Contact Terminal Blocks

Phoenix Contact 3002617 Disconnect terminal block, nom. voltage: 500 V, nominal current: 30 A, connection method: Push-in connection, cross section: 0.2 mm² - 6 mm², AWG: 24 - 10, length: 119.5 mm, width: 6.2 mm, color: gray, mounting: NS 35/7,5, NS 35/15
Phoenix Contact

Part#:3002617

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Disconnect terminal block, nom. voltage: 500 V, nominal current: 30 A, connection method: Push-in connection, cross section: 0.2 mm² - 6 mm², AWG: 24 - 10, length: 119.5 mm, width: 6.2 mm, color: gray, mounting: NS 35/7,5, NS 35/15

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3002617 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Bending test turns
    135
  • Color
    gray
  • Overvoltage category
    III
  • Maximum load current
    20 A
  • Back of the hand protection
    guaranteed
  • Result of power-frequency withstand voltage test
    Test passed
  • Insulating material
    PA
  • Degree of pollution
    3
  • Nominal voltage UN
    500 V
  • Result of surge voltage test
    Test passed
  • Bending test conductor cross section/weight
    0.2 mm² / 0.2 kg
  • Result of temperature-rise test
    Test passed
  • Short circuit stability result
    Test passed
  • Conductor cross section short circuit testing
    6 mm²
  • Result of aging test
    Test passed
  • Test spectrum
    Service life test category 1, class B, body mounted
  • ASD level
    0.964 (m/s2)2/Hz
  • Shock form
    Half-sine
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Connection method
    Push-in connection
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section AWG min.
    24
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    4 mm²
  • Connection cross sections directly pluggable
    0.5 mm² 6 mm² 20 10
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 10.0.1
    27141141
  • ETIM 4.0
    EC000901
  • UNSPSC 19.0
    39121410
  • UNSPSC 21.0
    39121410
  • Number of levels
    3
  • Height NS 35/7,5
    57.6 mm
  • Stripping length
    10 mm ... 12 mm
  • Conductor cross section AWG max.
    10
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.25 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    4 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ETIM 7.0
    EC000901
  • Number of connections
    5
  • Flammability rating according to UL 94
    V0
  • Maximum power dissipation for nominal condition
    1.6 W (the value is multiplied when connecting multiple levels)
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Bending test rotation speed
    10 rpm
  • Result of voltage-drop test
    Test passed
  • Short-time current
    0.72 kA
  • Result of thermal test
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Static insulating material application in cold
    -60 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Width
    6.2 mm
  • Conductor cross section solid max.
    6 mm²
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.25 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1 mm²
  • ECLASS 11.0
    27141141
  • ECLASS 9.0
    27141141
  • UNSPSC 13.2
    39121410
  • Nominal cross section
    4 mm²
  • Rated surge voltage
    6 kV
  • Insulating material group
    I
  • Nominal current IN
    20 A
  • Open side panel
    Yes
  • Finger protection
    guaranteed
  • Result of flexion and pull-out test
    Test passed
  • Tensile test result
    Test passed
  • Setpoint
    1 N
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test frequency
    f1 = 5 Hz to f2 = 150 Hz
  • Shock test result
    Test passed
  • Shock duration
    30 ms
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height
    54.5 mm
  • Connection in acc. with standard
    IEC 60947-7-3
  • Max. AWG conductor cross section, flexible
    10
  • Internal cylindrical gage
    A4
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 5.1
    27141100
  • ECLASS 6.0
    27141100
  • ETIM 6.0
    EC000901
  • UNSPSC 20.0
    39121410
  • Tight fit on carrier
    NS 35
  • Result of tight fit on support
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Oscillation, broadband noise test result
    Test passed
  • Test duration per axis
    5 h
  • Acceleration
    5g
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Number of shocks per direction
    3
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Length
    119.5 mm
  • Height NS 35/15
    65.1 mm
  • Conductor cross section flexible max.
    4 mm²
  • Min. AWG conductor cross section, flexible
    24
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 125°C)
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 5.0
    27141100
  • ECLASS 7.0
    27141141
  • UNSPSC 18.0
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo