Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

3210198 Phoenix Contact Terminal Blocks

Phoenix Contact 3210198 Disconnect terminal block, nom. voltage: 400 V, nominal current: 20 A, connection method: Push-in connection, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, length: 74 mm, width: 5.2 mm, color: gray, mounting: NS 35/7,5, NS 35/15
Phoenix Contact

Part#:3210198

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 2756

Dec 23, 2024

Disconnect terminal block, nom. voltage: 400 V, nominal current: 20 A, connection method: Push-in connection, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, length: 74 mm, width: 5.2 mm, color: gray, mounting: NS 35/7,5, NS 35/15

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3210198 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • ECLASS 4.0
    27141100
  • ETIM 4.0
    EC000902
  • UNSPSC 11
    39121410
  • Note
    The max. load current must not be exceeded by the total current of all connected conductors.Current and voltage are determined by the plug used.
  • Number of levels
    1
  • Number of connections
    3
  • Potentials
    1
  • Nominal cross section
    2.5 mm²
  • Color
    gray
  • Insulating material
    PA
  • Flammability rating according to UL 94
    V0
  • Rated surge voltage
    6 kV
  • Overvoltage category
    III
  • Insulating material group
    I
  • Maximum power dissipation for nominal condition
    0.77 W
  • Degree of pollution
    3
  • Maximum load current
    20 A (with 4 mm² conductor cross section, rigid)
  • Nominal current IN
    20 A
  • Nominal voltage UN
    400 V
  • Open side panel
    Yes
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Finger protection
    guaranteed
  • Result of surge voltage test
    Test passed
  • Result of power-frequency withstand voltage test
    Test passed
  • Back of the hand protection
    guaranteed
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Result of flexion and pull-out test
    Test passed
  • Bending test rotation speed
    10 rpm
  • Bending test turns
    135
  • Tensile test result
    Test passed
  • Result of tight fit on support
    Test passed
  • Tight fit on carrier
    NS 35
  • Bending test conductor cross section/weight
    0.14 mm² / 0.2 kg
  • Result of voltage-drop test
    Test passed
  • Result of temperature-rise test
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Short circuit stability result
    Test passed
  • Setpoint
    1 N
  • Conductor cross section short circuit testing
    2.5 mm²
  • Short-time current
    0.3 kA
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Result of thermal test
    Test passed
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Oscillation, broadband noise test result
    Test passed
  • Result of aging test
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2018-05
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • ASD level
    6.12 (m/s2)2/Hz
  • Test duration per axis
    5 h
  • Acceleration
    30g
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2018-05
  • Shock form
    Half-sine
  • Shock test result
    Test passed
  • Number of shocks per direction
    3
  • Shock duration
    18 ms
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Static insulating material application in cold
    -60 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Width
    5.2 mm
  • Height NS 35/15
    44 mm
  • Conductor cross section solid min.
    0.34 mm²
  • Conductor cross section AWG min.
    26
  • Conductor cross section flexible min.
    0.14 mm²
  • Max. AWG conductor cross section, flexible
    14
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • UNSPSC 21.0
    39121410
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height NS 35/7,5
    36.5 mm
  • Connection method
    Push-in connection
  • Conductor cross section flexible max.
    4 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.5 mm²
  • Connection cross sections directly pluggable
    0.34 mm² 4 mm²
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 5.0
    27141100
  • ECLASS 6.0
    27141100
  • UNSPSC 7.0901
    39121410
  • UNSPSC 18.0
    39121410
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • End cover width
    2.2 mm
  • Stripping length
    8 mm ... 10 mm
  • Min. AWG conductor cross section, flexible
    26
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    0.5 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 4.1
    27141100
  • ECLASS 9.0
    27141126
  • ETIM 7.0
    EC000902
  • UNSPSC 12.01
    39121410
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Length
    74 mm
  • Connection in acc. with standard
    CSA
  • Conductor cross section solid max.
    4 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    2.5 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • ECLASS 10.0.1
    27141126
  • ECLASS 11.0
    27141126
  • ETIM 2.0
    EC000897
  • ETIM 3.0
    EC000897
  • UNSPSC 13.2
    39121410
  • UNSPSC 19.0
    39121410
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Connection
    1 level
  • Conductor cross section AWG max.
    12
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    2.5 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.34 mm²
  • Internal cylindrical gage
    A3
  • ECLASS 5.1
    27141100
  • ECLASS 7.0
    27141126
  • ETIM 6.0
    EC000902
  • UNSPSC 6.01
    30211811
  • UNSPSC 20.0
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$4.74

Stock:

2,756

Select Qty:

$4.74

$4.74 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo