Filters
Manufacturer
Manual Motor Protectors
part#
description
manufacturer
KTA9-32S-1.0A-EY
KTA9 Explosion Proof Motor Controller, Frame C Standard Capacity, 0.63-1.0 Amps, 14A Magnetic Trip, 0.5 HP 460V / 0.5 HP 575V, NEMA Type 4/7/9, Black Off-On
Sprecher + Schuh
Quick Quote
KTA9-32S-1.0A-VJ
Sprecher + Schuh KTA9-32S-1.0A-VJ - KTA9 Enclosed Motor Circuit Controller, Frame C Standard Capacity, 0.63-1.0 Amps, 14A Magnetic Trip, 0.5 HP 460V / 0.5 HP 575V, Non-metallic Type 4 / 4X / 12 , Red/Yel Off-On
Sprecher + Schuh
Quick Quote
KTA9-32S-1.6A-CJ
Sprecher + Schuh KTA9-32S-1.6A-CJ - KTA9 Enclosed Motor Circuit Controller, Frame C Standard Capacity, 1.0-1.6 Amps, 22A Magnetic Trip, 0.75 HP 460V, Non-metallic Type 4/4X/12K - IP66, Red/Yel Off-On
Sprecher + Schuh
Quick Quote
KTA9-32S-16A-EY-UA480-BD
Sprecher + Schuh KTA9-32S-16A-EY-UA480-BD - KTA9 Explosion Proof Motor Controller, Frame C Standard Capacity, 10-16 Amps, 224A Magnetic Trip, 3 HP 200V / 5 HP 230V / 10 HP 460V / 10 HP 575V, NEMA Type 4/7/9, Black Off-On, Breather Drain, Undervoltage
Sprecher + Schuh
Quick Quote
KTA7-45H-16A
Sprecher + Schuh
Quick Quote
GVAU416
Schneider Electric GVAU416 is a coil with a main function as a tripping mechanism, specifically an undervoltage trip coil (MN), belonging to the GV2 sub-range. It features a rated insulation voltage (Ui) of 690 V and operates at a control voltage (AC) of 415 Vac at 60Hz. The mechanical durability of this part varies with the device it is used with; it can perform up to 30,000 operations when paired with GV2ME/GV2P and up to 10,000 operations with GV3P/GV3L. It is equipped with screw-clamp type terminals for secure connections.
Schneider Electric
Quick Quote
MPW100-3-U090
WEG MPW100-3-U090 - MOTOR PROTECTOR MPW100-3-U090, Manual Motor Protectors
WEG
Quick Quote
MPW18-3-C016
WEG MPW18-3-C016 - MOTOR PROTECTOR BU MPW18-3-C016, Manual Motor Protectors
WEG
Quick Quote
MPW18-3-D016
WEG MPW18-3-D016 - MOTOR PROTECTOR BU MPW18-3-D016, Manual Motor Protectors
WEG
Quick Quote
MPW18-3-U018
WEG MPW18-3-U018 - MOTOR PROTECTOR BU MPW18-3-U018, Manual Motor Protectors
WEG
Quick Quote
MPW18-3-U016
WEG MPW18-3-U016 - MOTOR PROTECTOR BU MPW18-3-U016, Manual Motor Protectors
WEG
Quick Quote
MPW40-3-C016
WEG MPW40-3-C016 - MOTOR PROTECTOR BU MPW40-3-C016, Manual Motor Protectors
WEG
Quick Quote
MPW40-3-C025
WEG MPW40-3-C025 - MOTOR PROTECTOR BU MPW40-3-C025, Manual Motor Protectors
WEG
Quick Quote
MPW40-3-C063
WEG MPW40-3-C063 - MOTOR PROTECTOR BU MPW40-3-C063, Manual Motor Protectors
WEG
Quick Quote
MPW40-3-U004
WEG MPW40-3-U004 - MOTOR PROTECTOR BU MPW40-3-U004, Manual Motor Protectors
WEG
Quick Quote
MPW40-3-U040
WEG MPW40-3-U040 - MOTOR PROTECTOR BU MPW40-3-U040, Manual Motor Protectors
WEG
Quick Quote
MPW65-3-U065
WEG MPW65-3-U065 - MOTOR PROTECTOR MPW65-3-U065, Manual Motor Protectors
WEG
Quick Quote
MPW80-3-U050
WEG MPW80-3-U050 - MOTOR PROTECTOR BU MPW80-3-U050, Manual Motor Protectors
WEG
Quick Quote
1SAM340000R1014
ABB 1SAM340000R1014 is a protection unit designed with thermal-magnetic circuit breaker functionality for transformer primary protection. It features screw-clamp connections and offers an adjustable rated current of 20A to 25A. The unit is designed to operate within an ambient air temperature range of -25 to +70°C for operation and -50 to +80°C for storage. It has a control voltage rating of IP20 and a rated impulse voltage (Uimp) of 6 kV. The dimensions include a net width of 45 mm, a net depth of 86.55 mm, and a length of 97.8 mm, making it suitable for mounting on DIN rails or mounting plates. This 3-pole (3P) device provides protection functions including short circuit protection, phase failure/loss, and transformer protection, with a rated insulation voltage (Ui) of 690 V. It supports an operating mode of up to 50,000 operations and a control flow with an ON/OFF/TRIP rotary knob, capable of 100,000 operations. The angular positions offer thermal protection for overloads adjustable between 20A and 25A, with a primary current and rated active power at 690 V.
ABB Control
Quick Quote
1SAM580000R1009
ABB 1SAM580000R1009 is a Motor Protection Circuit Breaker (MPCB) featuring thermal-magnetic motor protection. It is designed with screw-clamp connections and offers an adjustable rated current of 70A to 90A. This MPCB supports a rated voltage (AC) of IP20 and operates efficiently within an ambient air temperature range of -20 to +70°C for operation and -50 to +80°C for storage. It is equipped with a 3-pole (3P) configuration and provides short circuit protection, phase failure/loss, and thermal overload protection. The device has a net width of 165 mm, a net depth of 174 mm, and mounts on a DIN rail. It operates with a control voltage (AC) of 690 V and is capable of 25,000 operations. The MPCB supports a rated power of 30HP (UL/CSA at 208Vac) and 75HP (UL/CSA at 440-480Vac), with a primary voltage designed for 50,000 operations. It features magnetic protection with a short-circuit pickup current fixed at 1170A and thermal protection with an adjustable range of 70A to 90A.
ABB Control
Quick Quote
Items per page: