1SAM580000R1009
ABB 1SAM580000R1009 is a Motor Protection Circuit Breaker (MPCB) featuring thermal-magnetic motor protection. It is designed with screw-clamp connections and offers an adjustable rated current of 70A to 90A. This MPCB supports a rated voltage (AC) of IP20 and operates efficiently within an ambient air temperature range of -20 to +70°C for operation and -50 to +80°C for storage. It is equipped with a 3-pole (3P) configuration and provides short circuit protection, phase failure/loss, and thermal overload protection. The device has a net width of 165 mm, a net depth of 174 mm, and mounts on a DIN rail. It operates with a control voltage (AC) of 690 V and is capable of 25,000 operations. The MPCB supports a rated power of 30HP (UL/CSA at 208Vac) and 75HP (UL/CSA at 440-480Vac), with a primary voltage designed for 50,000 operations. It features magnetic protection with a short-circuit pickup current fixed at 1170A and thermal protection with an adjustable range of 70A to 90A.
ABB Control
Quick Quote
J7MN-3R-22
Omron J7MN-3R-22 - Contactor
Omron
Quick Quote
J7MN-3P-4
Omron J7MN-3P-4 - Mtr. Protective Crct Breaker
Omron
Quick Quote
J7MC-3R-2E5
J7MC Manual Motor Starter
Omron
Quick Quote
J7MC-3P-1E6
J7MC Manual Motor Starter
Omron
Quick Quote
J7MC-3P-E4
J7MC Manual Motor Starter
Omron
Quick Quote
J7MC-3R-13
J7MC Manual Motor Starter
Omron
Quick Quote
J7MC-3R-E16
J7MC Manual Motor Starter
Omron
Quick Quote
1SAM340000R1004
ABB 1SAM340000R1004 is a protection unit designed with thermal-magnetic circuit breaker functionality for transformer primary protection. It features screw-clamp connections and offers an adjustable rated current ranging from 0.4A to 0.63A. The unit operates within an ambient air temperature range for operation of -25 to +70°C and for storage from -50 to +80°C. It is designed with an IP20 control voltage (DC), a rated impulse voltage (Uimp) of 6 kV, and a net width of 45 mm. This 3-pole (3P) device provides protection functions including short circuit protection, phase failure/loss, and transformer protection. With a net depth of 86.75 mm and a rated insulation voltage (Ui) of 690 V, it supports a rated active power that allows for mounting on DIN rails or mounting plates. The primary current is rated at 690 V, and it is built for over 100,000 operations with an ON/OFF/TRIP rotary knob for control. The unit's angular positions offer thermal protection for overloads adjustable between 0.40A and 0.63A.
ABB Control
Quick Quote
1SAM350005R1006
ABB 1SAM350005R1006 is a Motor Protection Circuit Breaker (MPCB) designed for thermal-magnetic motor protection. It features manual motor starter protection with screw-clamp connections. The rated current is adjustable between 1A and 1.6A, with specific ratings for UL/CSA FLA Full Load Amps at 200Vac, 208Vac, 220-240Vac, 440-480Vac, and 550-600Vac, and for UL/CSA LRA Locked Rotor Amperes at the same voltages. It includes normally open (NO) auxiliary contacts rated for 208Vac. The device offers short circuit protection, phase failure/loss protection, and thermal overload protection with a Class 10 response. It has a rated insulation voltage (Ui) of 690V and a control voltage (AC) protection degree of IP20. The MPCB operates within an ambient air temperature range of -25 to +70°C for operation and offers a degree of protection for front-mounted auxiliary contact blocks (1NO+1NC). It has a net width of 90mm, a power consumption of 6kV, and comes in a color-coded design for easy identification. The connection capacity is 0.55kW / 550W at 400/415Vac, suitable for 3-poles (3P) configurations. It is designed for mounting on DIN rails or mounting plates and has a mechanical endurance of 100,000 operations. The product is replaced by an ON/OFF/TRIP rotary knob for simplified control.
ABB Control
Quick Quote
1SAM350005R1008
ABB 1SAM350005R1008 is a Motor Protection Circuit Breaker (MPCB) designed for thermal-magnetic motor protection. It features manual motor starter protection with screw-clamp connections. The rated current is adjustable between 2.5A and 4A, with a UL/CSA Full Load Amps (FLA) rating of 4A at 200Vac, 208Vac, and 220-240Vac, and a Locked Rotor Amperes (LRA) rating of 24A at the same voltages. It operates with a supply voltage (AC) of 550-600Vac, offering short circuit protection, phase failure/loss, and thermal overload Class 10 protection. The device includes a front-mounted auxiliary contact block (1NO+1NC) and is designed for a 3-pole (3P) configuration. It has a rated insulation voltage (Ui) of 690V and a control voltage (AC) of IP20. The MPCB is capable of 100,000 operations, with a mechanical durability (at no load) also rated at 100,000 operations. It features a magnetic protection short-circuit pickup current fixed at 50A and thermal protection for overload adjustable between 2.5A and 4A. The device is designed to mount on DIN rails or mounting plates, with a connection capacity of 1.5kW (400/415Vac). It operates within an ambient air temperature range of -25 to +70°C and offers a degree of protection of IP20.
ABB Control
Quick Quote
KTA7-45H-10A-WG
KTA7 Enclosed Motor Circuit Controller, Frame F High Capacity, 6.3-10 Amps, 130A Magnetic Trip, 2 HP 200V / 2 HP 230V / 5 HP 460V / 7.5 HP 575V, Painted Steel Type 4/12, Black Off-On
Sprecher + Schuh
Quick Quote
KTA9-32S-10A
Sprecher + Schuh KTA9-32S-10A - KTA9 Motor Protection Circuit Breaker, Frame C Standard Capacity, 6.3-10 Amps, 140A Magnetic Trip, 2 HP 200V / 2 HP 230V / 5 HP 460V / 7.5 HP 575V, Open Type
Sprecher + Schuh
Quick Quote
KTA7-45H-16A-EZ
Sprecher + Schuh KTA7-45H-16A-EZ - KTA7 Explosion Proof Motor Controller, Frame F High Capacity, 10-16 Amps, 208A Magnetic Trip, 3 HP 200V / 5 HP 230V / 10 HP 460V / 10 HP 575V, NEMA Type 4/7/9, Black Off-On
Sprecher + Schuh
Quick Quote
KTA7-45H-32A-EZ
Sprecher + Schuh KTA7-45H-32A-EZ - KTA7 Explosion Proof Motor Controller, Frame F High Capacity, 23-32 Amps, 416A Magnetic Trip, 7.5 HP 200V / 10 HP 230V / 20 HP 460V / 30 HP 575V , NEMA Type 4/7/9, Black Off-On
Sprecher + Schuh
Quick Quote
KTA7-45H-25A-VG
Sprecher + Schuh KTA7-45H-25A-VG - KTA7 Enclosed Motor Circuit Controller, Frame F High Capacity, 18-25 Amps, 325A Magnetic Trip, 7.5 HP 200V / 7.5 HP 230V / 15 HP 460V / 20 HP 575V, Non-metallic Type 4 / 4X / 12 , Black Off-On
Sprecher + Schuh
Quick Quote
KTA9-32S-0.16A
Sprecher + Schuh KTA9-32S-0.16A - KTA9 Motor Protection Circuit Breaker, Frame C Standard Capacity, 0.10-0.16 Amps, 2.2A Magnetic Trip, Open Type
Sprecher + Schuh
Quick Quote
KTA9-32S-0.16A-DG
KTA9 Enclosed Motor Circuit Controller, Frame C Standard Capacity, 0.10-0.16 Amps, 2.2A Magnetic Trip, Painted Steel Type 12, Black Off-On
Sprecher + Schuh
Quick Quote
KTA9-32S-16A-DG
KTA9 Enclosed Motor Circuit Controller, Frame C Standard Capacity, 10-16 Amps, 224A Magnetic Trip, 3 HP 200V / 5 HP 230V / 10 HP 460V / 10 HP 575V, Painted Steel Type 12, Black Off-On
Sprecher + Schuh
Quick Quote
KTA9-32S-16A-EX-BD-A11
Sprecher + Schuh KTA9-32S-16A-EX-BD-A11 - KTA9 Explosion Proof Motor Controller, Frame C Standard Capacity, 10-16 Amps, 224A Magnetic Trip, 3 HP 200V / 5 HP 230V / 10 HP 460V / 10 HP 575V, NEMA Type 7/9, Black Off-On, Breather Drain, 1NO 1NC Aux
Sprecher + Schuh
Quick Quote
Items per page: