1SDA062875R1
ABB 1SDA062875R1 is a Moulded Case Circuit Breaker (MCCB) designed for use in various applications requiring circuit protection. It features ring-lug or bar connections and operates with a rated current of 1250A and a rated voltage of 750Vdc. The device is equipped with a standard lever operating mechanism and has a control voltage of 690Vac. Its dimensions are specified as a net height of 8 kV, with a 4-pole configuration (4P4d) indicating its width. The MCCB offers protection functions against overload (L), short-circuit with time delay (S), and instantaneous protection against short-circuit (I), with a protection voltage of 1000 V. The technology used in this component is identified by the number 888614786851. It has a residual current sensitivity with dimensions of H268mm x W280mm x D154mm and a diameter of 690 V. The network frequency is described as T7S complete breakers, and it includes a visual position indicator with the number 39121616. Its electrical durability under load is facilitated by a toggle mechanism. The power dissipation/losses are noted as 1250 AT, with a trip current rating of 1250 AF. The programming languages indicate an electronic technology with a PR232/P LSI series, LSI protection, and no display. The short circuit current breaking capacity (Icn) includes adjustable settings for overload protection (0.4...1 x In, 500A...1250A), short-circuit protection with time delay (0.6...10 x In, 750A...12500A), and instantaneous protection against short-circuit (1...12 x In, 1250A...15000A). The short circuit withstand current (Icw) is rated at 20kA for 1 second.
ABB Control
Quick Quote
LGF36600U31XAE
Square D by Schneider Electric LGF36600U31XAE is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT LGF sub-range. It features a factory-installed 1A/1B (1NO+1NC) auxiliary switch (low level) in a PowerPact L-Frame, with a 600 Micrologic 3.3 (LI) 3P 600A configuration. This MCCB operates at a rated current of 600A and has a rated insulation voltage (Ui) of 750 V, with an AC rated voltage of 600Vac 600Y/347Vac. It is designed for individual unit mount on plate, with dimensions of 382 mm in height, 153 mm in width, and 171 mm in depth. The degree of protection is IP40, and it operates via a toggle (manual) mechanism. Protection functions include long-time protection (L) adjustable from 0.3 to 1 x In (50A to 150A) and instantaneous protection (I) adjustable from 1.5 to 11 x In (900A to 6600A). The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 600 AT, with a frame current rating of 600 AF. Its short circuit breaking rating varies from 65kA at 240Vac to 20kA at 500Vdc, according to UL489 standards. The trip unit type is an electronic Micrologic Standard 3.3 (LI) with no display, and it falls under utilisation category A. Connection is facilitated by a terminal nut kit for fixed busbar connection on both line and load sides.
Telemecanique Sensors
Quick Quote
HGF36150U31XAAUOYH1
Square D by Schneider Electric HGF36150U31XAAUOYH1 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT HGF sub-range. It features a factory-installed 24Vdc undervoltage (U/V) trip release coil and a factory-installed 1A/1B (1NO+1NC) auxiliary switch with wire harness. Designed for PowerPact H-Frame 150 Micrologic 3.2 (LI), it is a 3-pole (3P) device rated for 150A and capable of handling 600Vac/500Vdc with a busbar rating of 18kA at 80% rated capacity. The connection is facilitated by a terminal nut kit for fixed busbar connections on both line and load sides. It offers long-time (L) and instantaneous (I) protection functions, with a rated insulation voltage (Ui) of 750V, and operating voltages of 600Vac, 600Y/347Vac, and 500Vdc. The unit is designed for individual mounting on a plate, with dimensions of 163mm in height, 104mm in width, and 86mm in depth, and it has an IP40 degree of protection. The operating mode is manual toggle, with protection settings adjustable for overload (0.3...1 x In, 50A...150A) and short-circuit (1.5...15 x In, 225A...2250A). The control voltage for the undervoltage trip coil allows circuit breaker opening when the supply voltage drops to 35%-70% of its rated control voltage, and closing is permitted when it reaches 85% of the rated control voltage. The rated operating voltage (Ue) is 690V, with a rated impulse voltage (Uimp) of 8kV. The trip current rating is 150 AT, with a frame current rating of 150 AF, and short circuit breaking ratings as specified under UL489 standards. The trip unit type is an electronic Micrologic Standard 3.2 (LI) with no display, categorized under utilisation category A.
Telemecanique Sensors
Quick Quote
HDF36150U33X
Square D by Schneider Electric HDF36150U33X is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT HDF sub-range, featuring a PowerPact H-Frame 150 Micrologic 3.2S (LSI) design. It is a 3-pole (3P) device with a rated current of 150A and offers a connection via a terminal nut kit for fixed busbar connections on both line and load sides. This MCCB provides long-time protection (L), short-time protection with fixed time delay (S), and instantaneous protection (I), with adjustable settings for each protection function. It has a rated insulation voltage (Ui) of 750 V, a rated voltage (AC) of 600Vac/600Y/347Vac, and a rated voltage (DC) of 250Vdc. The device is designed for individual unit mount on plate, with a net height of 163 mm, a net width of 104 mm, and a net depth of 86 mm. It features a degree of protection of IP40 and operates via a toggle (manual). The MCCB has a rated operating voltage (Ue) of 690 V, a rated impulse voltage (Uimp) of 8 kV, and a trip current rating of 150 AT. Its frame current rating is 150 AF, and it has a short circuit breaking rating of 25kA at 240Vac, 18kA at 480Vac/480Y/277Vac, 14kA at 600Vac/600Y/347Vac, and 20kA at 250Vdc, all according to UL489 standards. The trip unit type is an electronic Micrologic Standard 3.2S (LSI) with no display, and it falls under utilisation category A.
Telemecanique Sensors
Quick Quote
RKF36120U44A
Square D by Schneider Electric RKF36120U44A is a Molded Case Circuit Breaker (MCCB) designed for mounting on a mounting plate. It operates at a rated voltage of 600 V AC and offers a range of protection functions including Long-time (L), Short-time with fixed time delay (S), Instantaneous (I), and Ground fault (G) protection. This MCCB falls under the PowerPact RKF sub-range and features a busbar connection type. It is rated for a current of 1200A and is equipped with three poles. The short circuit breaking rating is specified at 65kA across various voltages including 240Vac, 480Y/277Vac, 480Vac, 600Y/347Vac, and 600Vac. The trip current rating is 1200 AT, with a frame current rating of 3000 AF. It utilizes a Micrologic 6.0A (LSIG) Electronic trip unit and protects all three poles.
Schneider Electric
Quick Quote
RJF36300U33A
Square D by Schneider Electric RJF36300U33A is a molded case circuit breaker (MCCB) within the PowerPact RJF sub-range, designed for busbar connections. This 3-pole MCCB features long-time (L), short-time with fixed time delay (S), and instantaneous (I) protection functions. It has a rated current of 3000A and operates at a rated voltage of 600V AC. The device is mounted using a mounting plate and has a trip current rating as well as a frame current rating of 3000 AT and 3000 AF, respectively. Its short circuit breaking rating varies with voltage: 100kA at 240Vac, 65kA at both 480Y/277Vac and 480Vac, and 25kA at both 600Y/347Vac and 600Vac. All three poles are protected, and it utilizes a Micrologic 5.0 (LSI) electronic trip unit.
Schneider Electric
Quick Quote
RGF36300U31A
Square D by Schneider Electric RGF36300U31A is a Molded Case Circuit Breaker (MCCB) designed for mounting on a plate with a connection type of Busbar. It falls under the PowerPact RGF sub-range and is rated for a current of 3000A with a voltage rating of 600V AC. This 3-pole MCCB features protection functions including Long-time (L) and Instantaneous (I) protection. It has a trip current rating and frame current rating of 3000 AT and 3000 AF, respectively. The short circuit breaking rating is specified as 65kA at 240Vac, 35kA at 480Y/277Vac and 480Vac, and 18kA at 600Y/347Vac and 600Vac. All three poles are protected, and it utilizes a Micrologic 3.0 (LI) Electronic trip unit type.
Schneider Electric
Quick Quote
HDL36035T
Square D by Schneider Electric HDL36035T is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT HDL sub-range. It features a removable/interchangeable trip unit, designed for PowerPacT H-Frame 150 TMD, with 3 poles (3P) and a rated current of 35A. This MCCB operates at a rated insulation voltage (Ui) of 750 V, with AC rated voltages of 600Vac and 600Y/347Vac, and a DC rated voltage of 250Vdc. It offers thermal protection for overload and magnetic protection for short-circuit situations, with a net height of 163 mm, width of 104 mm, and depth of 86 mm. The device supports a mounting mode of individual unit mount on plate, has an IP40 degree of protection, and operates manually via a toggle. Protection settings include over-current fixed at 35A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 850A. Its rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 35 AT, with a frame current rating of 150 AF. It has a short circuit breaking rating of 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Vac and 600Y/347Vac, and 20kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display, and it falls under utilisation category A. Connections are made via lugs on both load and line sides.
Schneider Electric
Quick Quote
BJL46020
Square D by Schneider Electric BJL46020 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 4P 20A 600Y/347Vac 25kA design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes Everlink (Creep compensating) lugs for connections on both line and load sides, offering a degree of protection of IP40. The rated current is 20A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for mechanical durability of 20,000 operations at no load and can be mounted on a DIN rail or individually on a plate. This 4-pole (4P) circuit breaker has dimensions of 137 mm in height, 80 mm in depth, and 108 mm in width. It falls under utilisation category A and features over-current protection fixed at 20A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 20 AT and an electrical durability (with load) of 10,000 operations at 440Vac. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, including 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BJL26100
Square D by Schneider Electric BJL26100 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 2P 100A 600Y/347Vac 25kA design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes Everlink (Creep compensating) lugs for connections on both line and load sides, offering a degree of protection rated at IP40. The rated current is 100A, with an AC rated voltage of 600Vac 600Y/347Vac, and it has a mechanical durability of 20,000 operations at no load. This MCCB is designed for fixed mounting on DIN rail or as an individual unit mount on a plate, featuring 2 poles (2P). Its dimensions are 137 mm in height, 80 mm in depth, and 54 mm in width, falling under utilisation category A. Protection settings include over-current fixed at 100A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage for DC applications is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 100 AT and an electrical durability of 10,000 operations with load at 440Vac. The frame current rating is 100 AF, operated manually via a toggle, and it has a short circuit breaking rating that varies with voltage, including 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all in accordance with UL489. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric
Quick Quote
BJL26090
Square D by Schneider Electric BJL26090 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 2P 90A design for 600Y/347Vac with a 25kA short circuit breaking rating and 80% rated Everlink (Creep compensating) lugs on both line and load sides. It has a rated impulse voltage (Uimp) of 8 kV, an IP40 degree of protection, and a rated current of 90A. The MCCB operates at a rated voltage (AC) of 600Vac/600Y/347Vac, with mechanical durability of 20,000 operations and can be mounted on a DIN rail or as an individual unit on a plate. It features 2 poles (2P), with dimensions of 137 mm in height, 80 mm in depth, and 54 mm in width. The utilisation category is A, and it offers protection settings including over-current fixed at 90A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. Protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 90 AT and an electrical durability (with load) of 10,000 operations at 440Vac. The frame current rating is 100 AF, with a toggle (manual) operating mode, and a trip unit type that is Thermal-Magnetic (fixed) without a display.
Schneider Electric
Quick Quote
BJL26045
Square D by Schneider Electric BJL26045 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 2P 45A design for 600Y/347Vac with a 25kA short circuit breaking rating and 80% rated Everlink (Creep compensating) lugs on both line and load sides. It has a rated impulse voltage (Uimp) of 8 kV, IP40 degree of protection, and supports a rated current of 45A with a rated voltage (AC) of 600Vac 600Y/347Vac. This MCCB offers mechanical durability of 20,000 operations and can be mounted on a DIN rail or as an individual unit on a plate. It features 2 poles (2P), with dimensions of 137 mm in height, 80 mm in depth, and 54 mm in width. The utilisation category is A, and it includes protection settings for over-current fixed at 45A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 45 AT. Its electrical durability with load is rated for 10,000 operations at 440Vac; In, and it has a frame current rating of 100 AF. The operating mode is manual toggle, and the trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric
Quick Quote
BJL26035
Square D by Schneider Electric BJL26035 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 2P 35A 600Y/347Vac 25kA with Everlink (Creep compensating) lugs on both line and load sides for connections. It has a rated impulse voltage (Uimp) of 8 kV and offers a degree of protection of IP40. This MCCB is designed for a rated current of 35A and a rated voltage (AC) of 600Vac 600Y/347Vac. It boasts a mechanical durability of 20,000 operations at no load and can be mounted either on a DIN rail or as an individual unit on a plate. The device has 2 poles (2P) and dimensions of 137 mm in height, 80 mm in depth, and 54 mm in width. It falls under utilisation category A and features protection settings for over-current fixed at 35A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. Protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 35 AT. Its electrical durability with load is rated at 10,000 operations at 440Vac; In. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating is detailed as 100kA (240Vac; UL489), 65kA (480Vac; UL489), 65kA (480Y/277Vac; UL489), 25kA (600Y/347Vac; UL489), and 50kA (250Vdc; UL489). The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BJA261101
Square D by Schneider Electric BJA261101 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJA sub-range, featuring a PowerPact B-Frame 125 TMD 2P 110A design for 600Y/347Vac with a 25kA I-line AB 80% rating. It has an 8 kV rated impulse voltage (Uimp) and utilizes an I-line connection (AB phases) with an IP40 degree of protection. The rated current is 110A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It boasts a mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism. This 2-pole (2P) breaker has dimensions of 137 mm in height, 89 mm in depth, and 54 mm in width, falling under the utilisation category A. Its protection settings include over-current fixed at 110A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. It offers thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 110 AT and an electrical durability of 10,000 operations with load at 440Vac; In. The frame current rating is 125 AF, operated by a toggle (manual) with a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, and 25kA at 600Y/347Vac under UL489, including 50kA at 250Vdc. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric
Quick Quote
BJA260901
Square D by Schneider Electric BJA260901 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJA sub-range. It features a PowerPact B-Frame 100 TMD 2P 90A design, suitable for 600Y/347Vac with a 25kA I-line AB 80% rating. This MCCB has an 8 kV rated impulse voltage (Uimp) and utilizes an I-line connection for AB phases. It offers IP40 protection and supports a rated current of 90A with a rated voltage of 600Vac 600Y/347Vac. The mechanical durability of this part is rated for 20,000 operations at no load, and it is designed for mounting on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism. This 2-pole (2P) circuit breaker has dimensions of 137 mm in height, 89 mm in depth, and 54 mm in width. It falls under utilisation category A and features over-current protection fixed at 90A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage for DC applications is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. It provides thermal and magnetic protection functions, with a trip current rating of 90 AT and an electrical durability of 10,000 operations at 440Vac with load. The frame current rating is 100 AF, and it operates via a toggle (manual) mechanism. The short circuit breaking rating varies, with 100kA at 240Vac, 65kA at 480Vac and 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric
Quick Quote