Filters
Molded Case Circuit Breakers (MCCB)
part#
description
manufacturer
BJA260901
Square D by Schneider Electric BJA260901 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJA sub-range. It features a PowerPact B-Frame 100 TMD 2P 90A design, suitable for 600Y/347Vac with a 25kA I-line AB 80% rating. This MCCB has an 8 kV rated impulse voltage (Uimp) and utilizes an I-line connection for AB phases. It offers IP40 protection and supports a rated current of 90A with a rated voltage of 600Vac 600Y/347Vac. The mechanical durability of this part is rated for 20,000 operations at no load, and it is designed for mounting on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism. This 2-pole (2P) circuit breaker has dimensions of 137 mm in height, 89 mm in depth, and 54 mm in width. It falls under utilisation category A and features over-current protection fixed at 90A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage for DC applications is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. It provides thermal and magnetic protection functions, with a trip current rating of 90 AT and an electrical durability of 10,000 operations at 440Vac with load. The frame current rating is 100 AF, and it operates via a toggle (manual) mechanism. The short circuit breaking rating varies, with 100kA at 240Vac, 65kA at 480Vac and 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric
Quick Quote
BJA161251
Square D by Schneider Electric BJA161251 is a moulded case circuit breaker (MCCB) within the PowerPacT BJA sub-range. It features a PowerPact B-Frame 125 TMD 1P 125A 600Y/347Vac 25kA I-line design with an I-line connection (A phase) and is rated for an impulse voltage of 8 kV. This MCCB has an IP40 degree of protection and supports a rated current of 125A with a rated voltage of 600Vac 600Y/347Vac. It offers mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. The unit is a 1-pole (1P) device with dimensions of 137 mm in height, 89 mm in depth, and 27 mm in width. It falls under utilisation category A and features over-current protection fixed at 125A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage for DC applications is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 125 AT. Its electrical durability with load is rated for 10,000 operations at 240Vac; In, and it has a frame current rating of 125 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric
Quick Quote
BJA161101
Square D by Schneider Electric BJA161101 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJA sub-range, featuring a PowerPact B-Frame 125 TMD 1P 110A 600Y/347Vac 25kA I-line A 80% rated design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection (A phase) with a degree of protection rated at IP40. The rated current for this MCCB is 110A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for mechanical durability of 20000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. This 1-pole (1P) circuit breaker has a net height of 137 mm, a net depth of 89 mm, and a net width of 27 mm, falling under the utilisation category A. Its protection settings include over-current fixed at 110A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. It offers thermal protection (Overload) and magnetic protection (Short-circuit) with a trip current rating of 110 AT. The electrical durability with load is 10000 operations at 240Vac; In, and the frame current rating is 125 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 100kA at 240Vac; UL489, 65kA at 480Vac; UL489, 65kA at 480Y/277Vac; UL489, 25kA at 600Y/347Vac; UL489, and 50kA at 250Vdc; UL489. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BJA160901
Square D by Schneider Electric BJA160901 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJA sub-range, featuring a PowerPact B-Frame 100 TMD 1P 90A 600Y/347Vac 25kA I-line A 80% rated design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection (A phase). This MCCB offers a degree of protection of IP40 and has a rated current of 90A with a rated voltage (AC) of 600Vac 600Y/347Vac. Its mechanical durability is rated at 20,000 operations at no load, and it is designed to mount on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. The unit is a 1-pole (1P) device with dimensions of 137 mm in height, 89 mm in depth, and 27 mm in width. It falls under utilisation category A and features protection settings including over-current fixed at 90A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 90 AT. Its electrical durability with load is 10,000 operations at 240Vac; In, and it has a frame current rating of 100 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BGL46125LU
Square D by Schneider Electric BGL46125LU is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGL sub-range, featuring a PowerPact B-Frame 125 TMD with 4 poles (4P) and a rated current of 125A. It operates at a rated voltage of 600Vac 600Y/347Vac and a DC voltage of 250Vdc, with an impulse voltage rating (Uimp) of 8 kV. The connection type includes Everlink (Creep compensating) lugs on both line and load sides, plus a Control Wire terminal (CWT) on the line side only. It offers a degree of protection of IP40 and is designed for fixed mounting on DIN rail or as an individual unit mount on a plate. The MCCB has a mechanical durability of 20,000 operations at no load and an electrical durability of 10,000 operations with load at 440Vac. Its protection settings include over-current fixed at 125A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The device provides thermal protection against overload and magnetic protection against short-circuits, with a trip current rating of 125 AT and a frame current rating of 125 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 65kA at 240Vac, 35kA at 480Vac and 480Y/277Vac, and 18kA at 600Y/347Vac under UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric
Quick Quote
BGL26110
Square D by Schneider Electric BGL26110 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGL sub-range, featuring a PowerPact B-Frame 125 TMD 2P 110A design for 600Y/347Vac with an 18kA breaking capacity and 80% rated Everlink (Creep compensating) lugs on both line and load sides. It has a rated impulse voltage (Uimp) of 8 kV and offers a degree of protection of IP40. The rated current is 110A, with a rated voltage (AC) of 600Vac 600Y/347Vac. This MCCB has a mechanical durability of 20,000 operations at no load and can be mounted on a DIN rail or as an individual unit on a plate. It features 2 poles (2P) and has dimensions of 137 mm in height, 80 mm in depth, and 54 mm in width. The utilisation category is A, and it includes protection settings for over-current fixed at 110A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 110 AT. Its electrical durability with load is 10,000 operations at 440Vac; In, and it has a frame current rating of 125 AF. The operating mode is manual toggle, and the short circuit breaking rating varies from 65kA at 240Vac to 20kA at 250Vdc, according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BGL26090
Square D by Schneider Electric BGL26090 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGL sub-range, featuring a PowerPact B-Frame 100 TMD 2P 90A design for 600Y/347Vac with an 18kA breaking capacity and 80% rated Everlink (Creep compensating) lugs on both line and load sides. It has a rated impulse voltage (Uimp) of 8 kV, IP40 degree of protection, and a rated current of 90A. The MCCB operates at a rated voltage (AC) of 600Vac 600Y/347Vac, with a mechanical durability of 20,000 operations and can be mounted on a DIN rail or as an individual unit on a plate. It features 2 poles (2P), with dimensions of 137 mm in height, 80 mm in depth, and 54 mm in width. The utilisation category is A, and it offers protection settings for over-current fixed at 90A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V, and a rated operating voltage (Ue) of 525 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 90 AT. Its electrical durability with load is 10,000 operations at 440Vac; In, and it has a frame current rating of 100 AF. The operating mode is manual toggle, and the short circuit breaking rating varies from 65kA at 240Vac to 20kA at 250Vdc, according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BGF36090
Square D by Schneider Electric BGF36090 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGF sub-range, featuring a PowerPact B-Frame 100 TMD 3P-3t design for 90A 600Y/347Vac with an 18kA terminal nut at 80% rated capacity. It has a rated impulse voltage (Uimp) of 8 kV and utilizes a terminal nut kit for fixed busbar connection on both line and load sides. The device offers an IP40 degree of protection and supports a rated current of 90A with a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for mechanical durability up to 15,000 operations at no load and can be mounted on a DIN rail or individually on a plate. This 3-pole (3P) circuit breaker measures 137 mm in height, 80 mm in depth, and 81 mm in width. It falls under utilisation category A and features over-current protection fixed at 90A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 90 AT. The electrical durability with load is rated for 10,000 operations at 440Vac; In, and the frame current rating is 100 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 65kA at 240Vac, 35kA at 480Vac, 35kA at 480Y/277Vac, and 18kA at 600Y/347Vac according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric
Quick Quote
BGF36050
Square D by Schneider Electric BGF36050 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGF sub-range, featuring a PowerPact B-Frame 100 TMD 3P-3t design for 50A 600Y/347Vac with an 18kA terminal nut at 80% rated capacity. It has a rated impulse voltage (Uimp) of 8 kV and utilizes a terminal nut kit for fixed busbar connection on both line and load sides, offering a degree of protection of IP40. The rated current is 50A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It boasts a mechanical durability of 15,000 operations at no load and can be mounted on a DIN rail or as an individual unit on a plate. This 3-pole (3P) circuit breaker has dimensions of 137 mm in height, 80 mm in depth, and 81 mm in width. It falls under utilisation category A and features protection settings including over-current fixed at 50A, short-circuit hold current fixed at 480A, and short-circuit trip current fixed at 720A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 50 AT. Its electrical durability with load is rated for 10,000 operations at 440Vac; In, and it has a frame current rating of 100 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 65kA at 240Vac, 35kA at 480Vac, 35kA at 480Y/277Vac, and 18kA at 600Y/347Vac under UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric
Quick Quote
BGA161101
Square D by Schneider Electric BGA161101 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGA sub-range, featuring a PowerPact B-Frame 125 TMD 1P 110A 600Y/347Vac 18kA I-line A 80% rated design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection (A phase) with a degree of protection rated at IP40. The rated current is 110A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It boasts a mechanical durability of 20,000 operations at no load and is designed for mounting on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. This 1-pole (1P) circuit breaker has dimensions of 137 mm in height, 89 mm in depth, and 27 mm in width. It falls under utilisation category A and offers protection settings including over-current fixed at 110A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 110 AT. Its electrical durability with load is 10,000 operations at 240Vac; In, and it has a frame current rating of 125 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 65kA at 240Vac, 35kA at 480Vac, 35kA at 480Y/277Vac, 18kA at 600Y/347Vac, and 20kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BGA160901
Square D by Schneider Electric BGA160901 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGA sub-range, featuring a PowerPact B-Frame 100 TMD 1P 90A 600Y/347Vac 18kA I-line design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection (A phase) with a degree of protection rated at IP40. The rated current for this device is 90A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. This 1-pole (1P) circuit breaker has dimensions of 137 mm in height, 89 mm in depth, and 27 mm in width. It falls under utilisation category A and offers protection settings including over-current fixed at 90A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 90 AT. Its electrical durability with load is rated for 10,000 operations at 240Vac; In. The frame current rating is 100 AF, and it operates via a toggle (manual) mechanism. The short circuit breaking rating varies, with 65kA at 240Vac, 35kA at 480Vac, 35kA at 480Y/277Vac, 18kA at 600Y/347Vac, and 20kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric
Quick Quote
BGA160251
Square D by Schneider Electric BGA160251 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGA sub-range, featuring a PowerPact B-Frame 100 TMD 1P 25A 600Y/347Vac 18kA I-line design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection (A phase) with a degree of protection rated at IP40. The rated current is 25A, with a rated voltage (AC) of 600Vac 600Y/347Vac. This MCCB is designed for mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. It is a 1-pole (1P) device with dimensions of 137 mm in height, 89 mm in depth, and 27 mm in width. The utilisation category is A, and it offers protection settings including over-current fixed at 25A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V, and a rated operating voltage (Ue) of 240 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 25 AT. Its electrical durability with load is 10,000 operations at 240Vac; In, and it has a frame current rating of 100 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 65kA at 240Vac; UL489, 35kA at 480Vac; UL489, 35kA at 480Y/277Vac; UL489, 18kA at 600Y/347Vac; UL489, and 20kA at 250Vdc; UL489. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BGA141251
Square D by Schneider Electric BGA141251 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGA sub-range, featuring a PowerPact B-Frame 125 TMD 1P 125A 480Y/277Vac 35kA I-line design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection (A phase) with a degree of protection rated at IP40. The rated current is 125A, with AC rated voltage at 480Vac 480Y/277Vac. This MCCB is designed for mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. It is a 1-pole (1P) device with dimensions of 137 mm in height, 89 mm in depth, and 27 mm in width. The utilisation category is A, and it offers protection settings including over-current fixed at 125A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated DC voltage is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 125 AT. Its electrical durability with load is rated for 10,000 operations at 240Vac; In, and it has a frame current rating of 125 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 65kA at 240Vac, 35kA at both 480Vac and 480Y/277Vac under UL489, 14kA at 600Y/347Vac, and 20kA at 250Vdc, all under UL489. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BGA141101
Square D by Schneider Electric BGA141101 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGA sub-range, featuring a PowerPact B-Frame 125 TMD 1P 110A design for 480Y/277Vac with a 35kA I-line and an 80% rated capacity. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection specific to the A phase. This MCCB is designed with an IP40 degree of protection and supports a rated current of 110A across a rated voltage of 480Vac 480Y/277Vac. It boasts a mechanical durability of 20,000 operations at no load and is engineered for mounting on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism. The device is a 1-pole (1P) unit with dimensions of 137 mm in height, 89 mm in depth, and 27 mm in width. It falls under the utilisation category A and offers protection settings including over-current fixed at 110A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. Additionally, it has a rated voltage of 125Vdc, a rated insulation voltage (Ui) of 800 V, and a rated operating voltage (Ue) of 240 V. Its protection functions encompass thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 110 AT. The electrical durability with load is rated at 10,000 operations at 240Vac; In. The frame current rating stands at 125 AF, and it operates via a toggle (manual) mechanism. The short circuit breaking rating is detailed as 65kA at 240Vac, 35kA at both 480Vac and 480Y/277Vac under UL489 standards, 14kA at 600Y/347Vac, and 20kA at 250Vdc. The trip unit type is a fixed thermal-magnetic technology without a display.
Schneider Electric
Quick Quote
BGA140701
Square D by Schneider Electric BGA140701 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGA sub-range, featuring a PowerPact B-Frame 100 TMD 1P 70A 480Y/277Vac 35kA I-line design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection for the A phase. With a degree of protection rated at IP40 and a rated current of 70A, this MCCB operates at a rated voltage (AC) of 480Vac 480Y/277Vac. It is designed for mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism. This 1-pole (1P) unit has dimensions of 137 mm in height, 89 mm in depth, and 27 mm in width. It falls under utilisation category A and offers protection settings for over-current fixed at 70A, short-circuit hold current fixed at 640A, and short-circuit trip current fixed at 960A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 70 AT. The electrical durability with load is 10,000 operations at 240Vac; In, and it has a frame current rating of 100 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 65kA at 240Vac, 35kA at both 480Vac and 480Y/277Vac under UL489 standards, 14kA at 600Y/347Vac, and 20kA at 250Vdc. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BDL46050
Square D by Schneider Electric BDL46050 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 100 TMD 4P 50A design for 600Y/347Vac with a 14kA breaking capacity and Everlink (Creep compensating) lugs on both line and load sides. It has a rated impulse voltage (Uimp) of 8 kV, an IP40 degree of protection, and a rated current of 50A. The device operates at a rated voltage of 600Vac 600Y/347Vac, with mechanical durability of 20,000 operations and can be mounted on a DIN rail or as an individual unit on a plate. It has 4 poles (4P), with dimensions of 137 mm in height, 80 mm in depth, and 108 mm in width. The utilisation category is A, and it offers protection settings including over-current fixed at 50A, short-circuit hold current fixed at 480A, and short-circuit trip current fixed at 720A. The rated voltage for DC applications is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 50 AT and an electrical durability of 10,000 operations at 440Vac. The frame current rating is 100 AF, with a toggle (manual) operating mode and a short circuit breaking rating as specified for various voltages and standards. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric
Quick Quote
BDL46040
Square D by Schneider Electric BDL46040 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 100 TMD 4P 40A design for 600Y/347Vac with a 14kA breaking capacity and 80% rated Everlink (Creep compensating) lugs on both line and load sides. It has a rated impulse voltage (Uimp) of 8 kV, an IP40 degree of protection, and a rated current of 40A. The device operates at a rated voltage (AC) of 600Vac 600Y/347Vac, with mechanical durability of 20,000 operations and can be mounted on a DIN rail or as an individual unit on a plate. It features 4 poles (4P), with dimensions of 137 mm in height, 80 mm in depth, and 108 mm in width. The BDL46040 falls under utilisation category A and offers protection settings including over-current fixed at 40A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. It has a rated voltage (DC) of 250Vdc, rated insulation voltage (Ui) of 800 V, and a rated operating voltage (Ue) of 525 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 40 AT. Its electrical durability with load is rated for 10,000 operations at 440Vac; In, and it has a frame current rating of 100 AF. The operating mode is manual toggle, with a short circuit breaking rating of 25kA at 240Vac, 18kA at 480Vac, 18kA at 480Y/277Vac, 14kA at 600Y/347Vac, and 10kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BDL46020
Square D by Schneider Electric BDL46020 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 100 TMD 4P 20A 600Y/347Vac 14kA design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes Everlink (Creep compensating) lugs for connections on both line and load sides, offering a degree of protection of IP40. The rated current is 20A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for mechanical durability of 20,000 operations at no load and can be mounted either on a DIN rail or as an individual unit on a plate. This 4-pole (4P) circuit breaker has dimensions of 137 mm in height, 80 mm in depth, and 108 mm in width. It falls under utilisation category A and features protection settings for over-current fixed at 20A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. Its protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 20 AT. The electrical durability with load is rated for 10,000 operations at 440Vac; In. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies by voltage, with 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Y/347Vac according to UL489 standards, and 10kA at 250Vdc. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BDL36080LV
Square D by Schneider Electric BDL36080LV is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range. It features a PowerPact B-Frame 100 TMD 3P 80A design for 600Y/347Vac with a 14kA breaking capacity and includes Everlink (Creep compensating) lugs on both line and load sides, plus a Control Wire terminal (CWT) on the load side only. This MCCB has a rated impulse voltage (Uimp) of 8 kV, an IP40 degree of protection, and a rated current of 80A. It operates at a rated voltage of 600Vac 600Y/347Vac, with a mechanical durability of 20,000 operations and can be mounted on a DIN rail or as an individual unit on a plate. The device has 3 poles (3P), dimensions of 137 mm in height, 80 mm in depth, and 81 mm in width, and falls under utilisation category A. Its protection settings include over-current fixed at 80A, short-circuit hold current fixed at 800A, and short-circuit trip current fixed at 1200A. The rated voltage for DC applications is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. It offers thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 80 AT and an electrical durability of 10,000 operations at 440Vac. The frame current rating is 100 AF, and it operates via a toggle (manual) mechanism. The short circuit breaking rating varies by voltage, with 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, and 14kA at 600Y/347Vac according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric
Quick Quote
BDL36060LV
Square D by Schneider Electric BDL36060LV is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 100 TMD design. This 3-pole (3P) circuit breaker has a rated current of 60A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. It is equipped with Everlink (Creep compensating) lugs on both line and load sides, plus a Control Wire terminal (CWT) on the load side only, offering a degree of protection of IP40. The device has a mechanical durability of 20,000 operations at no load and can be mounted either on a DIN rail or as an individual unit on a plate. Its protection settings include over-current fixed at 60A, short-circuit hold current fixed at 640A, and short-circuit trip current fixed at 960A. The BDL36060LV has a net height of 137 mm, a net depth of 80 mm, and a net width of 81 mm. It provides thermal protection (overload) and magnetic protection (short-circuit) with a trip current rating of 60 AT. The electrical durability with load is rated at 10,000 operations at 440Vac; In, and it has a frame current rating of 100 AF. The operating mode is manual toggle, and it features a short circuit breaking rating of 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, and 14kA at 600Y/347Vac under UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
Items per page: