X20SL8100 B&R Electronic Components
Part#:X20SL8100
Manufacturer:B&R
Product Lifecycle:Active
In-stock parts: 1
Dec 23, 2024
X20 SafeLOGIC, safety controller, openSAFETY gateway, removable application memory: SafeKEY, 1 POWERLINK interface, controlled node, integrated 2-port hub, including power supply module, 1x terminal block X20TB52 and X20 end cover plate X20AC0SR1 (right)
Check out the X20SL8100 B&R price in the box on the right side or send a quick quote.
Product Details
- Weight190 g
- Temperature Operation Vertical mounting orientation 0 to 45°C
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction UINT 16
- Temperature Operation Horizontal mounting orientation 0 to 60°C
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction UDINT 16
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction INT 16
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction DINT 16
- Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction DINT 64
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction BOOL 128
- Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction UINT 128
- Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction BOOL 1024
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd Module <1*10-10
- Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction UDINT 64
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wireless <1*10-14 * Number of openSAFETY packets per hour
- Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction INT 128
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wired Negligible
- Dimensions Depth 75 mm
- Dimensions Height 99 mm
- Relative humidity Storage 5 to 95%, non-condensing
- Dimensions Width 62.5+0.2 mm
- Relative humidity Transport 5 to 95%, non-condensing
- Relative humidity Operation 5 to 95%, non-condensing
- Temperature Transport -40 to 85°C
- Temperature Derating -
- Temperature Storage -40 to 85°C
- Min. cycle time Fieldbus 200 µs
- Mounting orientation Horizontal Yes
- Mounting orientation Vertical Yes
- Transfer Auto-MDI/MDIX Yes
- Transfer Autonegotiation Yes
- Transfer Full-duplex No
- Transfer Physical layer 100BASE-TX
- Transfer Half-duplex Yes
- Additional SafeDESIGNER limit values Max. number of variable with variable status 1023
- Additional SafeDESIGNER limit values Max. number of force variables 64
- Max. resources available for SafeDESIGNER info window entries Marker count 16,382
- Additional SafeDESIGNER limit values Max. number of function block types 512
- Max. resources available for SafeDESIGNER info window entries Memory for standard output data 1024 bytes
- Max. resources available for SafeDESIGNER info window entries Memory for safe input data 6144 bytes
- Max. resources available for SafeDESIGNER info window entries Memory for standard input data 1024 bytes
- Max. resources available for SafeDESIGNER info window entries Memory for safe output data 2048 bytes
- Max. resources available for SafeDESIGNER info window entries Marker memory 262,144 bytes
- Max. resources available for SafeDESIGNER info window entries Stack memory 32,768 bytes
- Max. resources available for SafeDESIGNER info window entries FB instances 4096
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of linked Managing SafeDOMAINs Starting with mapp Safety 5.10.0 and hardware upgrade 2.2.1.0: 10
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. total number of data points for each direction 16
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. total data width for each direction 64 bytes
- Data exchange between SafeDOMAIN and SafeDOMAIN Use as Connected SafeDOMAIN Yes, starting with mapp Safety 5.10.0 and hardware upgrade 2.2.1.0
- Data exchange between CPU and SafeLOGIC controller Max. total data width for each direction 512 bytes
- Support for Safe Commissioning Options DINT 64
- Data exchange between SafeDOMAIN and SafeDOMAIN Use as Managing SafeDOMAIN Yes, starting with mapp Safety 5.10.0 and hardware upgrade 2.2.1.0
- Support for Safe Commissioning Options UDINT 64
- Support for Safe Commissioning Options INT 64
- Support for Safe Commissioning Options UINT 64
- Support for Safe Commissioning Options BOOL 512
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SFF >90%
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFD <2*10-5
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 Proof test interval (PT) 20 years
- EN ISO 13849-1:2015 Mission time Max. 20 years
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SIL CL SIL 3
- EN ISO 13849-1:2015 MTTFD 2500 years
- Certifications KR Yes
- EN ISO 13849-1:2015 Category Cat. 4
- Certifications EAC Yes
- Certifications ABS Yes
- EN ISO 13849-1:2015 DC >94%
- EN ISO 13849-1:2015 PL PL e
- Certifications LR ENV1
- Certifications ATEX Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
- Certifications HazLoc cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
- Certifications UL cULus E115267; Industrial control equipment
- Certifications DNV Temperature: A (0 - 45°C); Humidity: B (up to 100%); Vibration: A (0.7 g); EMC: B (bridge and open deck)
- Certifications Functional safety cULus FSPC E361559; Energy and industrial systems; Certified for functional safety; ANSI UL 1998:2013
- Diagnostics POWERLINK Yes, using LED status indicator
- Diagnostics SafeKEY Yes, using LED status indicator
- Certifications UKCA Yes
- Diagnostics CPU function Yes, using LED status indicator
- Certifications CE Yes
- System requirements mapp Technology Package mapp Safety 5.7.0 or later
- System requirements Safety Release 1.7 or later
- System requirements Automation Studio 4.0.16 or later
- System requirements Automation Runtime V3.08 or later (for AsSafety library F4.06 or later)
- System requirements SafeDESIGNER 3.1.0 or later
- Note Order SafeKEY and SafeLOGIC range of functions using the X20MK configurator.; X20 end cover plate (right) included in delivery; 12-pin X20 terminal block, safety-keyed, included in delivery; SafeKEY cover included in delivery
- Degree of protection per EN 60529 IP20
- Installation elevation above sea level 0 to 2000 m, no limitation
- Transfer rate 100 Mbit/s
- Type Type 3
- Input current Max. 0.25 A
- Line length Max. 100 m between 2 nodes (segment length)
- Reverse polarity protection Yes
- Variant 2x shielded RJ45 port (hub)
- Fieldbus POWERLINK controlled node
- Input voltage 24 VDC -15% / +20%
- Timing precision Time * 0.05 + Cycle time of the safety application
- Shortest task class cycle time 1 ms
- Max. number of SafeNODEs 100, depends on the number of available operating licenses on the SafeKEY
- Max. number of POWERLINK controlled nodes 50
- Power consumption 4.3 W
- B&R ID code 0xDD61
- System module CPU
- SafeMOTION support Yes, depends on the number of available operating licenses on the SafeKEY
- Cooling Fanless
- Interfaces POWERLINK
- Communication with each other Yes
- Status indicators CPU function, POWERLINK, SafeKEY
- Max. number of SafeMOTION axes 70, depends on the data width of the modules used
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price within minutes.
Stock:
1
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of B&R
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
B&R Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨