B&R X20SO2120 X20 safe digital output module, 2 safe type A digital outputs, with current monitoring, 24 VDC, 2 A, OSSD <500 µs
B&R

Part#:X20SO2120

Manufacturer:B&R

Product Lifecycle:Active

In-stock parts: 1

Dec 23, 2024

X20 safe digital output module, 2 safe type A digital outputs, with current monitoring, 24 VDC, 2 A, OSSD <500 µs

Check out the X20SO2120 B&R price in the box on the right side or send a quick quote.

Product Details

  • Temperature Operation Vertical mounting orientation
    0 to 50°C
  • Temperature Operation Horizontal mounting orientation
    0 to 60°C
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd Per channel
    <1*10-10
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wireless
    <1*10-14 * Number of openSAFETY packets per hour
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wired
    Negligible
  • Relative humidity Transport
    5 to 95%, non-condensing
  • Relative humidity Storage
    5 to 95%, non-condensing
  • Relative humidity Operation
    5 to 95%, non-condensing
  • Temperature Transport
    -40 to 85°C
  • Temperature Derating
    See section "Derating".
  • Temperature Storage
    -40 to 85°C
  • Mounting orientation Vertical
    Yes
  • Mounting orientation Horizontal
    Yes
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFD
    <2*10-5
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SFF
    >60% if parameter "Disable OSSD = Yes - Warning", ; >90% if parameter "Disable OSSD = No"
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 Proof test interval (PT)
    20 years
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SIL CL
    SIL 2 if parameter "Disable OSSD = Yes - Warning", ; SIL 3 if parameter "Disable OSSD = No"
  • EN ISO 13849-1:2015 MTTFD
    2500 years
  • EN ISO 13849-1:2015 Mission time
    Max. 20 years
  • EN ISO 13849-1:2015 DC
    >60% if parameter "Disable OSSD = Yes - Warning", ; >94% if parameter "Disable OSSD = No"
  • EN ISO 13849-1:2015 PL
    PL d if parameter "Disable OSSD = Yes - Warning", ; PL e if parameter "Disable OSSD = No"
  • Certifications ABS
    Yes
  • EN ISO 13849-1:2015 Category
    Cat. 3 if parameter "Disable OSSD = Yes - Warning", ; Cat. 4 if parameter "Disable OSSD = No"
  • Certifications KC
    Yes
  • Certifications EAC
    Yes
  • Certifications KR
    Yes
  • Certifications HazLoc
    cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
  • Certifications LR
    ENV1
  • Certifications DNV
    Temperature: A (0 - 45°C); Humidity: B (up to 100%); Vibration: A (0.7 g); EMC: B (bridge and open deck)
  • Certifications ATEX
    Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
  • Certifications UKCA
    Yes
  • Electrical isolation Channel - Bus
    Yes
  • Certifications UL
    cULus E115267; Industrial control equipment
  • Certifications CE
    Yes
  • Electrical isolation Channel - Channel
    No
  • Certifications Functional safety
    cULus FSPC E361559; Energy and industrial systems; Certified for functional safety; ANSI UL 1998:2013
  • Blackout mode Standalone mode
    No
  • Power consumption Internal I/O
    0.98 W
  • Power consumption Bus
    0.25 W
  • Blackout mode Scope
    Module
  • Diagnostics Outputs
    Yes, using LED status indicator and software
  • Blackout mode Function
    Module functionality
  • Pitch
    25+0.2 mm
  • System requirements mapp Technology Package
    mapp Safety 5.7.0 or later
  • System requirements Automation Studio
    3.0.71 or later
  • Diagnostics Module run/error
    Yes, using LED status indicator and software
  • System requirements Safety Release
    1.1 or later
  • System requirements SafeDESIGNER
    2.58 or later
  • System requirements Automation Runtime
    2.95 or later
  • Note
    Order 1x safety-keyed terminal block separately.; Order 1x safety-keyed bus module separately.
  • Installation elevation above sea level
    0 to 2000 m, no limitation
  • Test pulse length
    Max. 500 µs
  • Degree of protection per EN 60529
    IP20
  • Time between two test pulses
    Min. 49.5 ms
  • Max. capacitive load
    100 nF
  • Max. switching frequency
    See section "Inrush current behavior for output channels".
  • RDS(on)
    240 mΩ
  • Switching voltage
    I/O power supply minus voltage drop due to RDS(on)
  • Insulation voltage between channel and bus
    500 Veff
  • Open-circuit detection
    Via internal current measurement, ; output current <10 mA: Signal "CurrentOK" = FALSE, ; output current 10 to 50 mA: Signal "CurrentOK" = Undefined, ; output current >50 mA: Signal "CurrentOK" = TRUE
  • Peak short-circuit current
    See section "Inrush current behavior for output channels".
  • Nominal output current
    2 A
  • Variant
    FET, 1x positive switching, 1x negative switching, type A, output level readable, open-circuit detection
  • Error detection time
    1 s
  • Leakage current when the output is switched off
    <10 µA
  • Output protection
    See section "Inrush current behavior for output channels".
  • Braking voltage when switching off inductive loads
    Max. 90 VDC
  • Total nominal current
    4 A
  • Max. I/O cycle time
    800 µs
  • Additional power dissipation caused by actuators (resistive) [W]
    1.92
  • Voltage range
    24 VDC -15% / +20%
  • Quantity
    2
  • B&R ID code
    0x2009
  • Nominal voltage
    24 VDC
  • Integrated protection
    Reverse polarity protection
  • Status indicators
    I/O function per channel, operating state, module status
  • I/O module
    2 safe type A digital outputs, with current monitoring, 24 VDC, 2 A, OSSD <500 µs

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



1-year warranty

Get a quick Quote!

Request a quote, and we will send you price within minutes.

Stock:

1

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of B&R

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

B&R Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo