2320131 Phoenix Contact DC/DC Converters
Part#:2320131
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 241
Dec 22, 2024
Primary-switched QUINT DC/DC converter for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, input: 12 V DC, output: 24 V DC/5 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2320131 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height with alternative assembly 130 mm
- Degree of protection IP20
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Mains buffering time typ. 3 ms (12 V DC)
- Protective circuit/component Varistor
- POWER BOOST (IBoost) 6.25 A (-25 °C ... 40 °C permanent, UOUT = 24 V DC )
- Max. capacitive load unlimited
- MTBF (IEC 61709, SN 29500) > 1005000 h (40 °C)
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- Conductor cross section flexible max. 2.5 mm²
- Depth 125 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Type of protection Transient surge protection
- Nominal output current (IN) 5 A (-25 °C ... 60 °C)
- Connection in parallel Yes, for redundancy and increased capacity
- Maximum power dissipation in no-load condition 2 W
- Power loss nominal load max. 13.5 W
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section flexible min. 0.2 mm²
- Stripping length 7 mm
- EMC requirements for noise emission EN 61000-6-3
- UL approvals UL/C-UL listed UL 508
- Contact discharge 8 kV (Test Level 4)
- Comments Criterion A
- Signal 1 kV (Test Level 2 - asymmetrical)
- Surge voltage load (surge) EN 61000-4-5
- ECLASS 4.1 27210900
- ECLASS 4.0 27210900
- ECLASS 7.0 27210901
- UNSPSC 12.01 39121004
- UNSPSC 20.0 39121041
- Width 32 mm
- Depth with alternative assembly 35 mm
- Ambient temperature (start-up type tested) -40 °C
- Input voltage range 9 V DC ... 18 V DC
- Climatic class 3K3 (in acc. with EN 60721)
- Nominal output voltage 24 V DC ±1 %
- Derating 60 °C ... 70 °C (2.5%/K)
- Protection against overvoltage at the output (OVP) < 35 V DC
- Active current limitation Approximately 6.9 A
- Residual ripple < 75 mVPP
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG max. 12
- Rail applications EN 50121-4
- Electrostatic discharge EN 61000-4-2
- Input 1 kV (Test Level 2 - symmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 10.0.1 27210901
- ECLASS 9.0 27210901
- ETIM 7.0 EC002046
- UNSPSC 13.2 39121041
- UNSPSC 11 39121004
- Width with alternative assembly 122 mm
- Installation distance right/left (active) 15 mm / 15 mm (≤ 70 °C)
- Installation distance top/bottom (active) 50 mm / 50 mm (≤ 70 °C)
- Current consumption 15 A (12 V, IBOOST)
- Input fuse 25 A (internal (device protection))
- Setting range of the output voltage (USet) 18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
- Connection in series yes
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Efficiency > 90 %
- Insulation voltage input/output 1.5 kV (type test)
- Connection method Screw connection
- Screw thread M3
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Electromagnetic HF field EN 61000-4-3
- I/O/S asymmetrical
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ETIM 4.0 EC002540
- ECLASS 5.1 27210900
- UNSPSC 7.0901 39121004
- UNSPSC 21.0 39121041
- Height 130 mm
- Installation distance right/left 0 mm / 0 mm (≤ 70 °C)
- Installation distance top/bottom 50 mm / 50 mm (≤ 70 °C)
- Degree of pollution 2
- Nominal input voltage range 12 V DC
- Inrush current < 15 A (typical)
- Selective Fuse Breaking (ISFB) 30 A (12 ms)
- Feedback voltage resistance 35 V DC
- Peak switching voltages nominal load < 10 mVPP (20 MHz)
- Net weight 0.7 kg
- Protection class III
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section AWG min. 24
- EMC requirements for noise immunity EN 61000-6-1
- Standard - Safe isolation DIN VDE 0100-410
- Standard – Safety extra-low voltage EN 60950-1 (SELV)
- Test field strength 10 V/m (Test Level 3)
- Fast transients (burst) EN 61000-4-4
- Conducted interference EN 61000-4-6
- REACh SVHC Lead 7439-92-1
- ECLASS 5.0 27210900
- ETIM 6.0 EC002046
- UNSPSC 18.0 39121041
- Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
- Discharge in air 15 kV (Test Level 4)
- Frequency range 0.15 MHz ... 80 MHz
- Output 1 kV (Test Level 2 - symmetrical)
- Voltage 10 V (Test Level 3)
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 11.0 27210901
- ECLASS 6.0 27210900
- UNSPSC 6.01 30211502
- UNSPSC 19.0 39121041
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$447.49
Stock:
241
Select Qty:
$447.49
$447.49 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨