Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2320911 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2320911 Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, SFB Technology (Selective Fuse Breaking), input: 1-phase, output: 24 V DC / 10 A
Phoenix Contact

Part#:2320911

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 129

Dec 22, 2024

Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, SFB Technology (Selective Fuse Breaking), input: 1-phase, output: 24 V DC / 10 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2320911 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Height with alternative assembly
    130 mm
  • Installation distance right/left
    5 mm / 5 mm
  • Current consumption
    4 A (100 V AC)
  • Type of protection
    Transient surge protection
  • Selective Fuse Breaking (ISFB)
    60 A (12 ms)
  • POWER BOOST (IBoost)
    15 A (-25 °C ... 40 °C permanent, UOUT = 24 V DC )
  • Typical response time
    < 0.15 s
  • Insulation voltage input / PE
    3.5 kV AC (type test)
  • Connection method
    Screw connection
  • Screw thread
    M3
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard – Safety extra-low voltage
    IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Explosive atmosphere
    EN 60079-15 (Zone 2)
  • DeviceNet approval
    DeviceNet™ Power Supply Conformance Tested
  • Electrostatic discharge
    EN 61000-4-2
  • Electromagnetic HF field
    EN 61000-4-3
  • Frequency range
    0.15 MHz ... 80 MHz
  • Input
    2 kV (Test Level 3 - symmetrical)
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 5.1
    27049000
  • ECLASS 9.0
    27040701
  • UNSPSC 7.0901
    39121004
  • UNSPSC 13.2
    39121004
  • UNSPSC 20.0
    39121004
  • Dielectric strength maximum
    300 V AC
  • Input fuse
    10 A (slow-blow, internal)
  • Protective circuit/component
    Varistor, gas-filled surge arrester
  • Connection in series
    yes
  • Maximum power dissipation in no-load condition
    9.1 W
  • Efficiency
    typ. 92.5 % (230 V AC)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible max.
    2.5 mm²
  • Conductor cross section AWG max.
    12
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard - Equipment safety
    BG (design tested)
  • UL approvals
    UL/C-UL listed UL 508
  • SIQ
    BG (type approved)
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Test field strength
    10 V/m (Test Level 3)
  • Fast transients (burst)
    EN 61000-4-4
  • Surge voltage load (surge)
    EN 61000-4-5
  • REACh SVHC
    Lead 7439-92-1
  • Voltage
    10 V (Test Level 3)
  • ECLASS 7.0
    27049002
  • UNSPSC 6.01
    30211502
  • UNSPSC 12.01
    39121004
  • Nominal power consumption
    303 VA
  • Recommended breaker for input protection
    10 A ... 20 A (AC: Characteristics B, C, D, K)
  • Setting range of the output voltage (USet)
    18 V DC ... 29.5 V DC (> 24 V DC, constant capacity)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Protection against overvoltage at the output (OVP)
    ≤ 32 V DC
  • Net weight
    1.1 kg
  • Insulation voltage output / PE
    500 V DC (routine test)
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • Inrush current
    < 15 A
  • Nominal output voltage
    24 V DC ±1 %
  • Feedback voltage resistance
    ≤ 35 V DC
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • MTBF (IEC 61709, SN 29500)
    > 940000 h (25 °C)
  • Protection class
    I
  • Conductor cross section flexible min.
    0.2 mm²
  • Standard - Electrical safety
    IEC 60950-1/VDE 0805 (SELV)
  • HART FSK Physical Layer Test Specification Compliance
    Output voltage UOut compliant
  • Rail applications
    EN 50121-4
  • Mains variation/undervoltage
    SEMI F47-0706 Compliance Certificate
  • Contact discharge
    8 kV (Test Level 4)
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Comments
    Criterion A
  • Criterion A
    Normal operating behavior within the specified limits.
  • I/O/S
    asymmetrical
  • ECLASS 10.0.1
    27040701
  • ETIM 4.0
    EC000599
  • ETIM 6.0
    EC002540
  • UNSPSC 18.0
    39121004
  • UNSPSC 21.0
    39121004
  • Discharge current to PE
    < 3.5 mA
  • Mains buffering time
    typ. 36 ms (120 V AC)
  • Nominal output current (IN)
    10 A (-25 °C ... 60 °C, UOUT = 24 V DC)
  • Derating
    60 °C ... 70 °C (2.5%/K)
  • Output power
    240 W
  • Power loss nominal load max.
    22 W
  • Insulation voltage input/output
    4 kV AC (type test)
  • Conductor cross section AWG min.
    16
  • Stripping length
    7 mm
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • CSA
    CAN/CSA-C22.2 No. 60950-1-07
  • Shipbuilding approval
    DNV GL (EMC B), ABS, LR, RINA, NK, BV
  • Discharge in air
    15 kV (Test Level 4)
  • Output
    1 kV (Test Level 2 - symmetrical)
  • Conducted interference
    EN 61000-4-6
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 11.0
    27040701
  • ECLASS 5.0
    27049000
  • UNSPSC 11
    39121004
  • ETIM 7.0
    EC002540
  • UNSPSC 19.0
    39121004
  • Depth
    125 mm
  • Degree of protection
    IP20
  • AC frequency range
    50 Hz ... 60 Hz
  • Residual ripple
    < 50 mVPP (with nominal values)
  • Height
    130 mm
  • Width with alternative assembly
    122 mm
  • Ambient temperature (operation)
    -40 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Installation height
    ≤ 5000 m
  • Depth with alternative assembly
    63 mm
  • Degree of pollution
    2
  • ECLASS 4.0
    27040700
  • ECLASS 4.1
    27040700
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Assembly instructions
    alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
  • Width
    60 mm
  • Installation distance top/bottom
    50 mm / 50 mm
  • Max. permissible relative humidity (operation)
    100 % (at 25 °C, non-condensing)
  • Input voltage range
    85 V AC ... 264 V AC
  • Conductor cross section solid max.
    2.5 mm²
  • ECLASS 6.0
    27049000

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$678.26

Stock:

129

Select Qty:

$678.26

$678.26 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo