Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

3044197 Phoenix Contact Terminal Blocks

Phoenix Contact 3044197 Feed-through terminal block, nom. voltage: 1000 V, nominal current: 76 A, connection method: Screw connection, number of connections: 2, cross section: 1.5 mm² - 25 mm², AWG: 16 - 4, width: 12.2 mm, height: 54.4 mm, color: black, mounting type: NS 35/7,5,
Phoenix Contact

Part#:3044197

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Feed-through terminal block, nom. voltage: 1000 V, nominal current: 76 A, connection method: Screw connection, number of connections: 2, cross section: 1.5 mm² - 25 mm², AWG: 16 - 4, width: 12.2 mm, height: 54.4 mm, color: black, mounting type: NS 35/7,5,

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3044197 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Area of application
    Railway industry
  • Insulating material group
    I
  • Shock protection test specification
    IEC 60529:2001-02
  • Surge voltage test setpoint
    9.8 kV
  • Bending test rotation speed
    10 rpm
  • Tractive force setpoint
    135 N
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Result of thermal test
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • ASD level
    6.12 (m/s2)2/Hz
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Length
    55.5 mm
  • Stripping length
    14 mm
  • Tightening torque max
    3 Nm
  • Conductor cross section flexible max.
    25 mm²
  • Insulating material
    PA
  • Degree of pollution
    3
  • Maximum power dissipation for nominal condition
    2.43 W
  • Open side panel
    Yes
  • Result of power-frequency withstand voltage test
    Test passed
  • Tensile test result
    Test passed
  • Tight fit on carrier
    NS 32/NS 35
  • Short circuit stability result
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Shock duration
    18 ms
  • Static insulating material application in cold
    -60 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • End cover width
    2.2 mm
  • Height NS 35/7,5
    55 mm
  • Connection in acc. with standard
    IEC 60947-7-1
  • Conductor cross section AWG min.
    16
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    1 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    16 mm²
  • Maximum load current
    101 A (with 25 mm² conductor cross section)
  • Back of the hand protection
    guaranteed
  • Result of surge voltage test
    Test passed
  • Result of flexion and pull-out test
    Test passed
  • Bending test turns
    135
  • Result of temperature-rise test
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2018-05
  • Test duration per axis
    5 h
  • Shock form
    Half-sine
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Width
    12.2 mm
  • Rated surge voltage
    8 kV
  • Nominal voltage UN
    1000 V
  • Power frequency withstand voltage setpoint
    2.2 kV
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Result of tight fit on support
    Test passed
  • Requirements, voltage drop
    U1 ≤ 3,2 mVU2 ≤ 1,5 x U1dT ≤ 45 K
  • Conductor cross section short circuit testing
    16 mm²
  • Acceleration
    30g
  • Number of shocks per direction
    3
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Screw thread
    M5
  • Flammability rating according to UL 94
    V0
  • Overvoltage category
    III
  • Nominal current IN
    76 A
  • Finger protection
    guaranteed
  • Bending test conductor cross section/weight
    1.5 mm² / 0.4 kg
  • Conductor cross section tensile test
    25 mm²
  • Result of voltage-drop test
    Test passed
  • Short-time current
    1.92 kA
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Height
    54.4 mm
  • Tightening torque, min
    2.5 Nm
  • Conductor cross section solid min.
    1.5 mm²
  • Min. AWG conductor cross section, flexible
    16
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    16 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    10 mm²
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • Height NS 35/15
    62.5 mm
  • Connection method
    Screw connection
  • Conductor cross section flexible min.
    1.5 mm²
  • Max. AWG conductor cross section, flexible
    4
  • 2 conductors with same cross section, solid min.
    1 mm²
  • 2 conductors with same cross section, solid max.
    6 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 4.1
    27141100
  • ECLASS 11.0
    27141120
  • ECLASS 5.0
    27141100
  • ETIM 3.0
    EC000897
  • UNSPSC 6.01
    30211811
  • UNSPSC 19.0
    39121410
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    1 mm²
  • 2 conductors with same cross section, stranded min.
    1 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    6 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 7.0
    27141120
  • ETIM 7.0
    EC000897
  • UNSPSC 18.0
    39121410
  • UNSPSC 13.2
    39121410
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.75 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 10.0.1
    27141120
  • ETIM 2.0
    EC000897
  • UNSPSC 7.0901
    39121410
  • UNSPSC 20.0
    39121410
  • Number of connections
    2
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Note
    Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
  • ECLASS 4.0
    27141100
  • ECLASS 6.0
    27141100
  • UNSPSC 11
    39121410
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    1 mm²
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 9.0
    27141120
  • UNSPSC 21.0
    39121410
  • Number of levels
    1
  • Color
    black
  • Conductor cross section solid max.
    25 mm²
  • Conductor cross section AWG max.
    4
  • 2 conductors with same cross section, stranded max.
    6 mm²
  • Internal cylindrical gage
    A7
  • ETIM 4.0
    EC000897
  • Potentials
    1
  • ETIM 6.0
    EC000897
  • UNSPSC 12.01
    39121410
  • Nominal cross section
    16 mm²
  • ECLASS 5.1
    27141100

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo