3044225 Phoenix Contact Terminal Blocks
Part#:3044225
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 13202
Dec 22, 2024
Feed-through terminal block, nom. voltage: 1000 V, nominal current: 125 A, connection method: Screw connection, number of connections: 2, cross section: 1.5 mm² - 50 mm², AWG: 16 - 1/0, width: 16 mm, height: 65.1 mm, color: gray, mounting type: NS 35/7,5,
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3044225 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Proof of thermal characteristics (needle flame) effective duration 30 s
- End cover width 2.2 mm
- ECLASS 6.0 27141100
- ECLASS 4.0 27141100
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 16 mm²
- Width 16 mm
- Connection method Screw connection
- Conductor cross section flexible max. 50 mm²
- ECLASS 5.1 27141100
- Shock form Half-sine
- ETIM 7.0 EC000897
- Height 65.1 mm
- Screw thread M6
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 1.5 mm²
- ETIM 3.0 EC000897
- UNSPSC 18.0 39121410
- Conductor cross section AWG min. 16
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 9.0 27141120
- UNSPSC 6.01 30211811
- UNSPSC 13.2 39121410
- UNSPSC 20.0 39121410
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 1.5 mm²
- ETIM 6.0 EC000897
- UNSPSC 12.01 39121410
- UNSPSC 19.0 39121410
- Insulating material PA
- Maximum power dissipation for nominal condition 4.06 W
- Nominal voltage UN 1000 V
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Tensile test result Test passed
- Setpoint 10 N
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Oscillation, broadband noise test result Test passed
- ASD level 1.857 (m/s2)2/Hz
- Shock duration 30 ms
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Height NS 35/15 73.2 mm
- Potentials 1
- Area of application Railway industry
- Degree of pollution 3
- Open side panel No
- Result of temperature-rise test Test passed
- Test spectrum Service life test category 1, class B, body mounted
- Test frequency f1 = 5 Hz to f2 = 150 Hz
- Number of shocks per direction 3
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Length 61.2 mm
- Number of levels 1
- Overvoltage category III
- Nominal current IN 125 A
- Result of surge voltage test Test passed
- Bending test rotation speed 10 rpm
- Tight fit on carrier NS 35
- Finger protection guaranteed
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Result of voltage-drop test Test passed
- Short circuit stability result Test passed
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Test duration per axis 5 h
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Static insulating material application in cold -60 °C
- Number of connections 2
- Color gray
- Insulating material group I
- Maximum load current 150 A (with 50 mm² conductor cross section)
- Nominal cross section 35 mm²
- Flammability rating according to UL 94 V0
- Rated surge voltage 8 kV
- Back of the hand protection guaranteed
- Power frequency withstand voltage setpoint 2.2 kV
- Bending test turns 135
- Bending test conductor cross section/weight 1.5 mm² / 0.4 kg
- Result of thermal test Test passed
- Acceleration 5g
- Result of power-frequency withstand voltage test Test passed
- Result of flexion and pull-out test Test passed
- Result of tight fit on support Test passed
- Short-time current 6 kA
- Tightening torque, min 3.2 Nm
- Stripping length 18 mm
- 2 conductors with same cross section, solid min. 1.5 mm²
- Conductor cross section solid min. 1.5 mm²
- Min. AWG conductor cross section, flexible 16
- Note Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
- Conductor cross section flexible min. 1.5 mm²
- Conductor cross section AWG max. 1/0
- Conductor cross section flexible, with ferrule with plastic sleeve max. 35 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 10.0.1 27141120
- ETIM 2.0 EC000897
- ETIM 4.0 EC000897
- UNSPSC 7.0901 39121410
- Surface flammability NFPA 130 (ASTM E 162) passed
- Height NS 35/7,5 65.7 mm
- Conductor cross section flexible, with ferrule without plastic sleeve max. 35 mm²
- 2 conductors with same cross section, stranded max. 10 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 10 mm²
- Ambient temperature (actuation) -5 °C ... 70 °C
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Tightening torque max 3.7 Nm
- Conductor cross section solid max. 50 mm²
- Max. AWG conductor cross section, flexible 1/0
- Conductor cross section flexible, with ferrule with plastic sleeve min. 1.5 mm²
- Internal cylindrical gage B9
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 11.0 27141120
- UNSPSC 11 39121410
- ECLASS 5.0 27141100
- ECLASS 7.0 27141120
- Shock test result Test passed
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Connection in acc. with standard CSA
- Conductor cross section flexible, with ferrule without plastic sleeve min. 1.5 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ECLASS 4.1 27141100
- 2 conductors with same cross section, stranded min. 1.5 mm²
- 2 conductors with same cross section, solid max. 16 mm²
- Conductor cross section short circuit testing 50 mm²
- Test directions X-, Y- and Z-axis (pos. and neg.)
- UNSPSC 21.0 39121410
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$7.34
Stock:
13,202
Select Qty:
$7.34
$7.34 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨