X20DO4332 B&R Electronic Components
Part#:X20DO4332
Manufacturer:B&R
Product Lifecycle:Active
In-stock parts: 5
Dec 23, 2024
X20 digital output module, 4 outputs, 24 VDC, 2 A, source, 3-wire connections
Check out the X20DO4332 B&R price in the box on the right side or send a quick quote.
Product Details
- Temperature Operation Vertical mounting orientation -25 to 50°C
- Temperature Operation Horizontal mounting orientation -25 to 60°C
- Relative humidity Transport 5 to 95%, non-condensing
- Relative humidity Storage 5 to 95%, non-condensing
- Relative humidity Operation 5 to 95%, non-condensing
- Temperature Transport -40 to 85°C
- Temperature Storage -40 to 85°C
- Temperature Derating See section "Derating".
- Installation elevation above sea level >2000 m Reduction of ambient temperature by 0.5°C per 100 m
- Installation elevation above sea level 0 to 2000 m No limitation
- Mounting orientation Horizontal Yes
- Mounting orientation Vertical Yes
- Power consumption Actuator power supply Max. 12 W
- Switching frequency Inductive load See section "Switching inductive loads".
- Switching frequency Resistive load Max. 500 Hz
- Switching delay 1 → 0 <300 µs
- Switching delay 0 → 1 <300 µs
- Certifications KC Yes
- Certifications EAC Yes
- Certifications HazLoc cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
- Certifications UL cULus E115267; Industrial control equipment
- Certifications ATEX Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
- Certifications CE Yes
- Certifications UKCA Yes
- Power consumption Internal I/O 0.49 W
- Power consumption Bus 0.16 W
- Pitch 12.5+0.2 mm
- Diagnostics Module run/error Yes, using LED status indicator and software
- Degree of protection per EN 60529 IP20
- Diagnostics Outputs Yes, using LED status indicator and software (output error status)
- Note Order 1x terminal block X20TB12 separately.; Order 1x bus module X20BM11 separately.
- Electrical isolation Channel isolated from bus; Channel not isolated from channel and I/O power supply
- Short-circuit proof Yes
- Insulation voltage between channel and bus 500 Veff
- Peak short-circuit current <4 A (Rev.
- Voltage drop for short-circuit protection at 500 mA
Max. 2 V- Additional functions
Outputs can be connected in parallel to increase the output current.- Braking voltage when switching off inductive loads
Typ. 50 VDC- Switch-on in the event of overload shutdown or short-circuit shutdown
Approx. 10 ms (depends on the module temperature)- Voltage
Module power supply minus voltage drop for short-circuit protection- Diagnostic status
Output monitoring with 10 ms delay- Actuator power supply
0.5 A in total for output-independent actuator power supply- RDS(on)
100 mΩ (Rev.- Leakage current when the output is switched off
5 µA- Output circuit
Source- Connection type
3-wire connections- Output protection
Thermal shutdown in the event of overcurrent or short circuit (see value "Short-circuit peak current"); Internal freewheeling diode for switching inductive loads (see section "Switching inductive loads")- Nominal voltage
24 VDC- I/O module
4 digital outputs 24 VDC for 3-wire connections- Total nominal current
8 A (Rev.- B&R ID code
0x1B9C- Status indicators
I/O function per channel, operating state, module status- Switching voltage
24 VDC -15% / +20%- Additional power dissipation caused by actuators (resistive) [W]
+1.6 (Rev.- Variant
Current-sourcing FET- Nominal output current
2 AProduct condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
Related documents X20DO4332 Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price within minutes.
Stock:
5
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of B&R
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
B&R Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨
- Voltage drop for short-circuit protection at 500 mA