Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

1046616 Phoenix Contact Terminal Blocks

Phoenix Contact 1046616 Distribution block, bridged internally, The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories, nom. voltage: 450 V, nominal current: 17.5 A, connection method: Push-in connection, number of
Phoenix Contact

Part#:1046616

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 65

Dec 22, 2024

Distribution block, bridged internally, The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories, nom. voltage: 450 V, nominal current: 17.5 A, connection method: Push-in connection, number of

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1046616 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Nominal cross section
    1.5 mm²
  • Insulating material group
    I
  • Maximum total current
    26 A
  • Result of surge voltage test
    Test passed
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Result of tight fit on support
    Test passed
  • Conductor cross section short circuit testing
    2.5 mm²
  • Short circuit stability result
    Test passed
  • ASD level
    6.12 (m/s2)2/Hz
  • Shock form
    Half-sine
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Width
    8.3 mm
  • Connection in acc. with standard
    IEC 60998-2-2
  • Max. AWG conductor cross section, flexible
    12
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.34 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 11.0
    27141120
  • ECLASS 9.0
    27141120
  • ETIM 4.0
    EC000897
  • UNSPSC 13.2
    39121410
  • UNSPSC 20.0
    39121410
  • Potentials
    1
  • Overvoltage category
    III
  • Maximum load current
    22 A
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Result of flexion and pull-out test
    Test passed
  • Bending test turns
    135
  • Result of voltage-drop test
    Test passed
  • Result of aging test
    Test passed
  • Note
    Notes on operation The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories
  • Color
    black
  • Flammability rating according to UL 94
    V0
  • Degree of pollution
    3
  • Open side panel
    No
  • Surge voltage test setpoint
    7.3 kV
  • Tractive force setpoint
    50 N
  • Setpoint
    1 N
  • Result of thermal test
    Test passed
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2018-05
  • Acceleration
    30g
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Conductor cross section solid min.
    0.34 mm²
  • Conductor cross section AWG max.
    14
  • Number of levels
    1
  • Rated surge voltage
    6 kV
  • Nominal current IN
    17.5 A
  • Finger protection
    guaranteed
  • Back of the hand protection
    guaranteed
  • Tensile test result
    Test passed
  • Bending test conductor cross section/weight
    0.14 mm² / 0.2 kg
  • Result of temperature-rise test
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Connection method
    Push-in connection
  • Conductor cross section solid max.
    2.5 mm²
  • Conductor cross section flexible min.
    0.14 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    1.5 mm²
  • Connection cross sections directly pluggable
    0.34 mm² 2.5 mm² 26 14
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 5.0
    27141120
  • ETIM 6.0
    EC000897
  • UNSPSC 6.01
    30211811
  • UNSPSC 12.01
    39121410
  • Number of connections
    4
  • Insulating material
    PA
  • Maximum power dissipation for nominal condition
    0.56 W
  • Nominal voltage UN
    450 V
  • Result of power-frequency withstand voltage test
    Test passed
  • Conductor cross section tensile test
    2.5 mm²
  • Tight fit on carrier
    NS 35/NS 15
  • Short-time current
    0.3 kA
  • Oscillation, broadband noise test result
    Test passed
  • Shock test result
    Test passed
  • Shock duration
    18 ms
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Length
    21.6 mm
  • Conductor cross section flexible max.
    1.5 mm²
  • Min. AWG conductor cross section, flexible
    24
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 5.1
    27141120
  • ECLASS 7.0
    27141120
  • UNSPSC 18.0
    39121410
  • UNSPSC 21.0
    39121410
  • Number of shocks per direction
    3
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Conductor cross section AWG min.
    26
  • Internal cylindrical gage
    A1 / B1
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 4.0
    27141121
  • ECLASS 6.0
    27141100
  • ETIM 7.0
    EC000897
  • UNSPSC 11
    39121410
  • UNSPSC 19.0
    39121410
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 10.0.1
    27141120
  • ETIM 3.0
    EC000897
  • UNSPSC 7.0901
    39121410
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.34 mm²
  • Test duration per axis
    5 h
  • Stripping length
    8 mm ... 10 mm
  • Bending test rotation speed
    10 rpm
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    1.5 mm²
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Height
    17.7 mm
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2018-05
  • Static insulating material application in cold
    -60 °C
  • ECLASS 4.1
    27141121

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$1.58

Stock:

65

Select Qty:

$1.58

$1.58 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo