Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

3044226 Phoenix Contact Terminal Blocks

Phoenix Contact 3044226 Feed-through terminal block, nom. voltage: 1000 V, nominal current: 125 A, connection method: Screw connection, number of connections: 2, cross section: 1.5 mm² - 50 mm², AWG: 16 - 1/0, width: 16 mm, height: 65.1 mm, color: black, mounting type: NS 35/7,5
Phoenix Contact

Part#:3044226

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Feed-through terminal block, nom. voltage: 1000 V, nominal current: 125 A, connection method: Screw connection, number of connections: 2, cross section: 1.5 mm² - 50 mm², AWG: 16 - 1/0, width: 16 mm, height: 65.1 mm, color: black, mounting type: NS 35/7,5

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3044226 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Number of levels
    1
  • Insulating material
    PA
  • Maximum power dissipation for nominal condition
    4.06 W
  • Nominal current IN
    125 A
  • Bending test rotation speed
    10 rpm
  • Tensile test result
    Test passed
  • Short circuit stability result
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test duration per axis
    5 h
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Length
    61.2 mm
  • Screw thread
    M6
  • Conductor cross section solid min.
    1.5 mm²
  • Conductor cross section AWG min.
    16
  • Conductor cross section AWG max.
    1/0
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    1.5 mm²
  • 2 conductors with same cross section, stranded min.
    1.5 mm²
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 4.0
    27141100
  • ECLASS 5.1
    27141100
  • ECLASS 6.0
    27141100
  • UNSPSC 13.2
    39121410
  • UNSPSC 21.0
    39121410
  • Number of connections
    2
  • Flammability rating according to UL 94
    V0
  • Insulating material group
    I
  • Open side panel
    No
  • Power frequency withstand voltage setpoint
    2.2 kV
  • Bending test conductor cross section/weight
    1.5 mm² / 0.4 kg
  • Result of temperature-rise test
    Test passed
  • Conductor cross section short circuit testing
    50 mm²
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Test frequency
    f1 = 5 Hz to f2 = 150 Hz
  • Number of shocks per direction
    3
  • Static insulating material application in cold
    -60 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Height NS 35/7,5
    65.7 mm
  • Height
    65.1 mm
  • Note
    Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
  • Conductor cross section flexible max.
    50 mm²
  • 2 conductors with same cross section, solid max.
    16 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    1.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 10.0.1
    27141120
  • ECLASS 5.0
    27141100
  • UNSPSC 6.01
    30211811
  • Potentials
    1
  • Degree of pollution
    3
  • Maximum load current
    150 A (with 50 mm² conductor cross section)
  • Back of the hand protection
    guaranteed
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Bending test turns
    135
  • Setpoint
    10 N
  • Test spectrum
    Service life test category 1, class B, body mounted
  • ASD level
    1.857 (m/s2)2/Hz
  • Shock test result
    Test passed
  • Shock form
    Half-sine
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Connection method
    Screw connection
  • Tightening torque max
    3.7 Nm
  • Conductor cross section solid max.
    50 mm²
  • Max. AWG conductor cross section, flexible
    1
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    35 mm²
  • 2 conductors with same cross section, stranded max.
    10 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    16 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 11.0
    27141120
  • ETIM 7.0
    EC000897
  • UNSPSC 11
    39121410
  • Nominal cross section
    35 mm²
  • Overvoltage category
    III
  • Nominal voltage UN
    1000 V
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Finger protection
    guaranteed
  • Result of flexion and pull-out test
    Test passed
  • Tight fit on carrier
    NS 35
  • Result of thermal test
    Test passed
  • Oscillation, broadband noise test result
    Test passed
  • Acceleration
    5g
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Width
    16 mm
  • Stripping length
    18 mm
  • Conductor cross section flexible min.
    1.5 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    35 mm²
  • Internal cylindrical gage
    B9
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 4.1
    27141100
  • Color
    black
  • Rated surge voltage
    8 kV
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of surge voltage test
    Test passed
  • Result of tight fit on support
    Test passed
  • Result of voltage-drop test
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Short-time current
    6 kA
  • Shock duration
    30 ms
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • End cover width
    2.2 mm
  • Height NS 35/15
    73.2 mm
  • Tightening torque, min
    3.2 Nm
  • Connection in acc. with standard
    IEC 60947-7-1
  • Min. AWG conductor cross section, flexible
    16
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    1.5 mm²
  • 2 conductors with same cross section, solid min.
    1.5 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    1.5 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    10 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ETIM 3.0
    EC000897
  • ECLASS 9.0
    27141120
  • ETIM 4.0
    EC000897
  • UNSPSC 19.0
    39121410
  • UNSPSC 18.0
    39121410
  • UNSPSC 7.0901
    39121410
  • ETIM 6.0
    EC000897
  • ECLASS 7.0
    27141120
  • UNSPSC 20.0
    39121410
  • UNSPSC 12.01
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo