2904376 Phoenix Contact AC/DC Power Supplies
Part#:2904376
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 442
Dec 22, 2024
Primary-switched UNO power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/150 W
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2904376 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- UNSPSC 18.0 39121004
- Width 37 mm
- Ambient temperature (start-up type tested) -25 °C
- Degree of pollution 2
- Frequency range (fN) 50 Hz ... 60 Hz 10 %
- Input fuse 2.5 A (slow-blow, internal)
- Nominal output current (IN) 6.25 A (-25 °C ... 55 °C)
- Type of protection Transient surge protection
- Connection in series No
- Typical response time < 1 s
- Power loss nominal load max. < 9.7 W
- Net weight 0.5 kg
- Assembly instructions alignable: 0 mm horizontally, 30 mm vertically
- Conductor cross section flexible max. 2.5 mm²
- Conductor cross section AWG max. 14
- EMC requirements for noise immunity EN 61000-6-1
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Standard - Safe isolation DIN VDE 0100-410
- UL approvals UL/C-UL listed UL 508
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Discharge in air 8 kV (Test Level 3)
- Comments Criterion A
- Surge voltage load (surge) EN 61000-4-5
- Criterion A Normal operating behavior within the specified limits.
- Voltage 10 V (Test Level 3)
- Installation distance top/bottom 30 mm / 30 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Depth 125 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
- Climatic class 3K3 (in acc. with EN 60721)
- Input voltage range 85 V AC ... 264 V AC
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Protective circuit/component Varistor
- Setting range of the output voltage (USet) 24 V DC ... 28 V DC ±1 %
- Derating 55 °C ... 70 °C (2.5%/K)
- Output power 150 W
- Efficiency typ. 91 % (120 V AC)
- Housing material Polycarbonate
- Conductor cross section solid min. 0.2 mm²
- Mounting position horizontal DIN rail NS 35, EN 60715
- Screw thread M3
- EMC requirements for noise emission EN 61000-6-3
- Stripping length 8 mm
- Mains variation/undervoltage EN 61000-4-11
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Electrostatic discharge EN 61000-4-2
- Electromagnetic HF field EN 61000-4-3
- Frequency range 0.15 MHz ... 80 MHz
- Fast transients (burst) EN 61000-4-4
- Output 1 kV (Test Level 2 - symmetrical)
- Conducted interference EN 61000-4-6
- ECLASS 10.0.1 27040701
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 5.0 27049000
- ETIM 4.0 EC000599
- UNSPSC 19.0 39121004
- ETIM 7.0 EC002540
- Height 130 mm
- Degree of protection IP20
- Nominal input voltage range 100 V AC ... 240 V AC
- Current consumption 1.66 A (100 V AC)
- Nominal power consumption 164.7 VA
- Inrush current < 50 A (typical)
- Connection in parallel Yes, for redundancy and increased capacity
- Feedback voltage resistance < 35 V DC
- Residual ripple < 40 mVPP (with nominal values)
- Insulation voltage input/output 4 kV AC (type test)
- MTBF (IEC 61709, SN 29500) > 868000 h (40 °C)
- Conductor cross section solid max. 2.5 mm²
- Connection method Screw connection
- Conductor cross section AWG min. 24
- Standard - Safety of transformers EN 61558-2-16
- Standard - Electrical safety IEC 62368-1/VDE 0805 (SELV)
- Standard – Safety extra-low voltage IEC 62368-1 (SELV) und EN 60204-1 (PELV)
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Contact discharge 6 kV (Test Level 3)
- Test field strength 10 V/m (Test Level 3)
- Input 2 kV (Test Level 3 - symmetrical)
- Voltage dips EN 61000-4-11
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 4.0 27040700
- ECLASS 5.1 27049000
- ECLASS 9.0 27040701
- ETIM 6.0 EC002540
- UNSPSC 20.0 39121004
- UNSPSC 21.0 39121004
- Installation distance right/left 0 mm / 0 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- AC frequency range 50 Hz ... 60 Hz
- Mains buffering time > 20 ms (120 V AC)
- Power factor (cos phi) 0.97
- Nominal output voltage 24 V DC ±1 %
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Protection against overvoltage at the output (OVP) ≤ 35 V DC
- Maximum power dissipation in no-load condition < 1.2 W
- Protection class II (in closed control cabinet)
- Foot latch material POM (Polyoxymethylen)
- Conductor cross section flexible min. 0.2 mm²
- ECLASS 11.0 27040701
- ECLASS 4.1 27040700
- ECLASS 6.0 27049000
- ECLASS 7.0 27049002
- UNSPSC 13.2 39121004
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$114.53
Stock:
442
Select Qty:
$114.53
$114.53 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.