2904595 Phoenix Contact AC/DC Power Supplies
Part#:2904595
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 171
Dec 22, 2024
Primary-switched power supply unit, QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 5 V DC / 5 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2904595 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 106 mm
- Depth 90 mm
- Degree of protection IP20
- Installation distance right/left (active) 15 mm / 15 mm (POut ≥50% )
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Installation height ≤ 5000 m (> 2000 m, observe derating)
- Input fuse 3.15 A (slow-blow, internal)
- Nominal output current (IN) 5 A
- Connection in parallel Yes, for redundancy and increased capacity
- Typical response time 350 ms
- Protection class II
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section AWG max. 14
- Standard – Safety extra-low voltage IEC 61010-1 (SELV)
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Flicker EN 61000-3-3
- Frequency range 50 Hz ... 60 Hz
- Output 1 kV (Test Level 3 - symmetrical)
- Conducted interference EN 61000-4-6
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 11.0 27040701
- Width 22.5 mm
- Installation distance right/left (active, passive) 0 mm / 0 mm (POut ≤50 %)
- Installation distance top/bottom (active) 30 mm / 30 mm (POut ≥50% )
- Ambient temperature (start-up type tested) -40 °C
- Dielectric strength maximum 300 V AC (60 s)
- Nominal power consumption 32.8 VA
- Type of protection Transient surge protection
- Static Boost (IStat.Boost) 6.25 A (≤ 40 °C)
- Protection against overvoltage at the output (OVP) < 8 V DC
- Residual ripple < 40 mVPP (with nominal values)
- Efficiency typ. 87.4 % (120 V AC)
- Conductor cross section AWG min. 24
- Standard - Safety of transformers EN 61558-2-16
- UL approvals UL Listed UL 61010-1
- Conducted noise emission EN 55016
- Contact discharge 8 kV (Test Level 4)
- Signal 0.5 kV (Test Level 2 - symmetrical)
- Voltage 1 kV (symmetrical)
- Voltage dips EN 61000-4-11
- Voltage dip 0 %
- Attenuated oscillating wave EN 61000-4-18
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- Installation distance right/left (passive) 5 mm / 5 mm (POut ≥50% )
- Installation distance top/bottom (passive) 30 mm / 30 mm (POut ≥50% )
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Frequency range (fN) 50 Hz ... 60 Hz -10 % ... +10 %
- Inrush current typ. 9.1 A (at 25 °C)
- Mains buffering time typ. 52 ms (120 V AC)
- Setting range of the output voltage (USet) 5 V DC ... 6.2 V DC (constant capacity)
- Dynamic Boost (IDyn.Boost) 8 A (≤ 60 °C (5 s))
- Control deviation < 0.3 % (change in load, static 10 % ... 90 %)
- Maximum power dissipation in no-load condition < 0.37 W (120 V AC)
- MTBF (IEC 61709, SN 29500) > 1890000 h (25 °C)
- Conductor cross section flexible max. 2.5 mm²
- Standard - Safety of power supply units up to 1100 V (insulation distances) DIN EN 61558-2-16
- Standard - Electrical safety IEC 61010-1 (SELV)
- Standard - power supply devices for low voltage with DC output EN 61204-3
- Harmonic currents EN 61000-3-2
- Electromagnetic HF field EN 61000-4-3
- Comments Criterion A
- I/O/S asymmetrical
- Frequency 60 Hz
- Attenuated sinusoidal oscillations (ring wave) EN 61000-4-12
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 5.1 27242213
- Installation distance top/bottom (active, passive) 30 mm / 30 mm (POut ≤50 %)
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Climatic class 3K3 (in acc. with EN 60721)
- Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
- Current consumption 0.37 A (100 V AC)
- Recommended breaker for input protection 6 A ... 16 A (Characteristic B, C or comparable)
- Nominal output voltage 5 V DC
- Feedback voltage resistance ≤ 16 V DC (16 V e-caps in output circuit)
- Power loss nominal load max. < 3.7 W (120 V AC)
- Insulation voltage input/output 4 kV AC (type test)
- Connection method Push-in connection
- Conductor cross section solid min. 0.2 mm²
- Standard - Safe isolation IEC 61558-2-16
- SIQ CB-Scheme (IEC 61010-1, IEC 61010-2-201)
- Noise emission EN 55016
- Discharge in air 15 kV (Test Level 4)
- Fast transients (burst) EN 61000-4-4
- Surge voltage load (surge) EN 61000-4-5
- Power frequency magnetic field EN 61000-4-8
- Pulse-shape magnetic field EN 61000-4-9
- Test level 1 16.67 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
- ECLASS 10.0.1 27040701
- Degree of pollution 2
- Discharge current to PE < 0.25 mA (264 V AC, 60 Hz)
- Protective circuit/component Varistor
- Connection in series yes
- Output power 25 W
- Net weight 0.184 kg
- Conductor cross section flexible min. 0.2 mm²
- Stripping length 10 mm
- Standard - safety for equipment for measurement, control, and laboratory use IEC 61010-1
- Rail applications EN 50121-3-2
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Electrostatic discharge EN 61000-4-2
- Test field strength 1000 A/m
- Input 2 kV (symmetrical)
- Additional text Test Level 2
- Number of periods 0.5 / 1 / 5 / 50 periods
- Test level 2 16.67 Hz 50 Hz 60 Hz (Test Level 2)
- ECLASS 9.0 27040701
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$104.78
Stock:
171
Select Qty:
$104.78
$104.78 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨