2904625 Phoenix Contact AC/DC Power Supplies
Part#:2904625
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 46
Dec 22, 2024
Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, NFC interface, and protective coating, input: 1-phase, output: 24 V DC / 10 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2904625 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Nominal input voltage range 100 V AC ... 240 V AC
- AC frequency range 50 Hz ... 60 Hz -10 % ... +10 %
- Nominal power consumption 274 VA
- Mains buffering time typ. 42 ms (120 V AC)
- Dynamic Boost (IDyn.Boost) 20 A (5 s)
- Connection in series yes
- Residual ripple < 80 mVPP (with nominal values)
- Power loss nominal load max. < 20 W (120 V AC)
- Insulation voltage output / PE 0.5 kV DC (type test)
- Connection method Push-in connection
- Conductor cross section AWG max. 16
- Standard – Safety extra-low voltage IEC 61010-1 (SELV)
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Additional text Test Level 2
- Harmonic currents EN 61000-3-2
- Signal 4 kV (Test Level 4 - asymmetrical)
- Surge voltage load (surge) EN 61000-4-5
- Frequency 50 Hz
- Attenuated sinusoidal oscillations (ring wave) EN 61000-4-12
- Test level 5 16.7 Hz 50 Hz 60 Hz (Test Level 4)
- Input, output (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 10.0.1 27040701
- Installation distance top/bottom 50 mm / 50 mm
- Degree of pollution 2
- Discharge current to PE < 3.5 mA
- Input fuse 8 A (slow-blow, internal)
- Protective circuit/component Varistor, gas-filled surge arrester
- Static Boost (IStat.Boost) 12.5 A
- Derating > 60 °C (2.5%/K)
- Protection against overvoltage at the output (OVP) ≤ 32 V DC
- Environmental protection directive RoHS Directive 2011/65/EU
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section flexible min. 0.2 mm²
- EMC requirements for noise immunity EN 61000-6-1
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Standard - Safe isolation IEC 61010-2-201
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Contact discharge 8 kV (Test Level 4)
- Test field strength 100 A/m
- Input 2 kV (Test Level 4 - symmetrical)
- I/O/S asymmetrical
- Voltage dip 0 %
- Test level 1 15 Hz 150 Hz (Test Level 4)
- Attenuated oscillating wave EN 61000-4-18
- Input, output (test level 3) Test Level 3 - asymmetrical
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- ECLASS 11.0 27040701
- Depth 125 mm
- Depth with alternative assembly 53 mm
- Degree of protection IP20
- Max. permissible relative humidity (operation) ≤ 100 % (at 25 °C, non-condensing)
- Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
- Current consumption 3.4 A (100 V AC)
- Recommended breaker for input protection 10 A ... 16 A (Characteristic B, C, D, K or comparable)
- Power factor (cos phi) 0.94
- Setting range of the output voltage (USet) 24 V DC ... 29.5 V DC (constant capacity)
- Connection in parallel Yes, for redundancy and increased capacity
- Typical response time 300 ms (from SLEEP MODE)
- Efficiency typ. 92.5 % (120 V AC)
- Insulation voltage input / PE 3.5 kV AC (type test)
- Conductor cross section solid max. 1 mm²
- Stripping length 8 mm
- HART FSK Physical Layer Test Specification Compliance Output voltage UOut compliant
- Mains variation/undervoltage SEMI F47-0706, EN 61000-4-11
- Shipbuilding approval DNV GL, PRS, BV, LR, ABS
- DNV GL conducted interference Class A
- Discharge in air 15 kV (Test Level 4)
- Comments Criterion A
- Power frequency magnetic field EN 61000-4-8
- Number of periods 0,5 / 1 / 5 / 50 / 250 periods
- Test level 3 1.5 kHz 15 kHz (Test Level 4)
- Test level 4 15 kHz 150 kHz (Test Level 4)
- REACh SVHC Lead 7439-92-1
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- Installation distance right/left 5 mm / 5 mm
- Ambient temperature (start-up type tested) -40 °C
- Installation height ≤ 5000 m (> 2000 m, observe derating)
- Frequency range (fN) 50 Hz ... 60 Hz -10 % ... +10 %
- Inrush current typ. 12 A (at 25 °C)
- Type of protection Transient surge protection
- Nominal output voltage 24 V DC
- Selective Fuse Breaking (ISFB) 60 A (15 ms)
- Feedback voltage resistance ≤ 35 V DC
- Maximum power dissipation in no-load condition < 3 W (120 V AC)
- Net weight 0.9 kg
- Insulation voltage input/output 4 kV AC (type test)
- Conductor cross section solid min. 0.2 mm²
- EMC requirements for noise emission EN 61000-6-3
- Standard - Electrical safety IEC 61010-2-201 (SELV)
- Rail applications EN 50121-3-2
- SIQ BG (type approved)
- Noise emission EN 55016
- Electrostatic discharge EN 61000-4-2
- Electromagnetic HF field EN 61000-4-3
- Fast transients (burst) EN 61000-4-4
- Conducted interference EN 61000-4-6
- Voltage 2.5 kV
- Test level 2 150 Hz 1.5 kHz (Test Level 4)
- Input, output (test level 2) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
- Test level 6 16.7 Hz 50 Hz 60 Hz (Test Level 4)
- ECLASS 9.0 27040701
- Control deviation < 0.5 % (Static load change 10 % ... 90 %)
- Output power 240 W
- MTBF (IEC 61709, SN 29500) > 1251000 h (25 °C)
- Protection class I
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- Conductor cross section AWG min. 24
- Standard - Safety of transformers IEC 61558-2-16 pending
- EMC requirements, power plant IEC 61850-3
- Standard - safety for equipment for measurement, control, and laboratory use IEC 61010-1
- UL approvals UL Listed UL 508
- Conducted noise emission EN 55016
- DNV GL noise radiation Class B
- Frequency range 50 Hz ... 60 Hz
- Output 1 kV (Test Level 3 - symmetrical)
- Voltage dips EN 61000-4-11
- Pulse-shape magnetic field EN 61000-4-9
- Damped oscillating magnetic field EN 61000-4-10
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Signals (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- Signals (test level 2) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
- Height 130 mm
- Height with alternative assembly 130 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Climatic class 3K3 (in acc. with EN 60721)
- Dielectric strength maximum 300 V AC 60 s
- Nominal output current (IN) 10 A
- Flicker EN 61000-3-3
- Width 50 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Width with alternative assembly 122 mm
- Conductor cross section flexible max. 1.5 mm²
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$326.29
Stock:
46
Select Qty:
$326.29
$326.29 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨