Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2904623 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2904623 Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 3-phase, output: 24 V DC/40 A
Phoenix Contact

Part#:2904623

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 830

Dec 22, 2024

Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 3-phase, output: 24 V DC/40 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2904623 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Voltage
    2.5 kV
  • Depth
    125 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Nominal input voltage range
    3x 400 V AC ... 500 V AC
  • Discharge current to PE
    < 3.5 mA
  • Type of protection
    Transient surge protection
  • Nominal output current (IN)
    40 A
  • Control deviation
    < 0.5 % (Static load change 10 % ... 90 %)
  • Residual ripple
    < 50 mVPP (with nominal values)
  • MTBF (IEC 61709, SN 29500)
    > 849000 h (25 °C)
  • Connection method
    Push-in connection
  • Conductor cross section flexible max.
    1.5 mm²
  • HART FSK Physical Layer Test Specification Compliance
    Output voltage UOut compliant
  • Standard - safety for equipment for measurement, control, and laboratory use
    IEC 61010-1
  • UL approvals
    UL Listed UL 508
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Harmonic currents
    EN 61000-3-2
  • DNV GL noise radiation
    Class B
  • Comments
    Criterion A
  • Input
    2 kV (Test Level 4 - symmetrical)
  • Installation distance right/left
    5 mm / 5 mm
  • Climatic class
    3K3 (in acc. with EN 60721)
  • AC frequency range
    50 Hz ... 60 Hz -10 % ... +10 %
  • Power factor (cos phi)
    0.95
  • Protective circuit/component
    Varistor, gas-filled surge arrester
  • Dynamic Boost (IDyn.Boost)
    60 A (5 s)
  • Connection in series
    yes
  • Output power
    960 W
  • Insulation voltage input/output
    4 kV AC (type test)
  • Protection class
    I
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Conductor cross section AWG max.
    16
  • EMC requirements, power plant
    IEC 61850-3
  • Standard - Safety of transformers
    EN 61558-2-16
  • Rail applications
    EN 50121-3-2
  • SIQ
    BG (type approved)
  • Additional text
    Test Level 2
  • Electrostatic discharge
    EN 61000-4-2
  • Fast transients (burst)
    EN 61000-4-4
  • I/O/S
    asymmetrical
  • Power frequency magnetic field
    EN 61000-4-8
  • Damped oscillating magnetic field
    EN 61000-4-10
  • Test level 6
    16.7 Hz 50 Hz 60 Hz (Test Level 4)
  • Signals (test level 2)
    100 kHz 1 MHz (Test Level 3 - asymmetrical)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 9.0
    27040701
  • Contact discharge
    8 kV (Test Level 4)
  • Height
    130 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Degree of pollution
    2
  • Input voltage range
    3x 400 V AC ... 500 V AC -20 % ... +10 %
  • Nominal power consumption
    1217 VA
  • Inrush current
    typ. 1.5 A (at 25 °C)
  • Nominal output voltage
    24 V DC
  • Selective Fuse Breaking (ISFB)
    215 A (15 ms)
  • Feedback voltage resistance
    ≤ 35 V DC
  • Typical response time
    300 ms (from SLEEP MODE)
  • Efficiency
    typ. 95.7 % (400 V AC)
  • Insulation voltage output / PE
    0.5 kV DC (type test)
  • Conductor cross section solid max.
    1 mm²
  • Conductor cross section flexible min.
    0.2 mm²
  • Standard - Electrical safety
    IEC 61010-2-201 (SELV)
  • Standard - Safe isolation
    IEC 61558-2-16
  • Mains variation/undervoltage
    SEMI F47-0706, EN 61000-4-11
  • Noise emission
    EN 55016
  • Frequency range
    50 Hz ... 60 Hz
  • Surge voltage load (surge)
    EN 61000-4-5
  • Voltage dip
    0 %
  • Test level 2
    150 Hz 1.5 kHz (Test Level 4)
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Input, output (test level 1)
    100 kHz 1 MHz (Test Level 3 - symmetrical)
  • Signals (test level 1)
    100 kHz 1 MHz (Test Level 3 - symmetrical)
  • ETIM 7.0
    EC002540
  • Width
    120 mm
  • Degree of protection
    IP20
  • Ambient temperature (start-up type tested)
    -40 °C
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Current consumption
    3x 1.8 A (400 V AC)
  • Mains buffering time
    typ. 28 ms (3x 400 V AC)
  • Static Boost (IStat.Boost)
    45 A
  • Derating
    > 60 °C ... 70 °C (2.5%/K)
  • Maximum power dissipation in no-load condition
    < 5 W (400 V AC)
  • Environmental protection directive
    RoHS Directive 2011/65/EU
  • Insulation voltage input / PE
    3.5 kV AC (type test)
  • Conductor cross section AWG min.
    24
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Shipbuilding approval
    DNV GL, BV, LR, ABS
  • Flicker
    EN 61000-3-3
  • DNV GL conducted interference
    Class A
  • Electromagnetic HF field
    EN 61000-4-3
  • Signal
    4 kV (Test Level 2 - asymmetrical)
  • Frequency
    50 Hz
  • Number of periods
    0,5 / 1 / 5 / 50 / 250 periods
  • Test level 4
    15 kHz 150 kHz (Test Level 4)
  • Input, output (test level 2)
    10 MHz
  • Criterion A
    Normal operating behavior within the specified limits.
  • REACh SVHC
    Lead 7439-92-1
  • ETIM 6.0
    EC002540
  • Installation distance top/bottom
    50 mm / 50 mm
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Installation height
    ≤ 5000 m (> 2000 m, observe derating)
  • Frequency range (fN)
    50 Hz ... 60 Hz -10 % ... +10 %
  • Recommended breaker for input protection
    3x 4 A ... 20 A (Characteristic B, C, D, K or comparable)
  • Setting range of the output voltage (USet)
    24 V DC ... 29.5 V DC (constant capacity)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Protection against overvoltage at the output (OVP)
    ≤ 32 V DC
  • Net weight
    2.6 kg
  • Power loss nominal load max.
    < 45 W (400 V AC)
  • Conductor cross section solid min.
    0.2 mm²
  • Stripping length
    8 mm
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard – Safety extra-low voltage
    IEC 61010-1 (SELV)
  • CSA
    CAN/CSA-C22.2 No. 60950-1-07
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Conducted noise emission
    EN 55016
  • Discharge in air
    15 kV (Test Level 4)
  • Test field strength
    100 A/m
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Conducted interference
    EN 61000-4-6
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Attenuated sinusoidal oscillations (ring wave)
    EN 61000-4-12
  • Test level 5
    16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 4)
  • Input, output (test level 3)
    100 kHz 1 MHz (Test Level 3 - asymmetrical)
  • ECLASS 10.0.1
    27040701
  • Voltage dips
    EN 61000-4-11
  • Test level 1
    15 Hz 150 Hz (Test Level 4)
  • Test level 3
    1.5 kHz 15 kHz (Test Level 4)
  • Attenuated oscillating wave
    EN 61000-4-18
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • ECLASS 11.0
    27040701

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$563.45

Stock:

830

Select Qty:

$563.45

$563.45 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo