2904623 Phoenix Contact AC/DC Power Supplies
Part#:2904623
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 830
Dec 22, 2024
Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 3-phase, output: 24 V DC/40 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2904623 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Voltage 2.5 kV
- Depth 125 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Nominal input voltage range 3x 400 V AC ... 500 V AC
- Discharge current to PE < 3.5 mA
- Type of protection Transient surge protection
- Nominal output current (IN) 40 A
- Control deviation < 0.5 % (Static load change 10 % ... 90 %)
- Residual ripple < 50 mVPP (with nominal values)
- MTBF (IEC 61709, SN 29500) > 849000 h (25 °C)
- Connection method Push-in connection
- Conductor cross section flexible max. 1.5 mm²
- HART FSK Physical Layer Test Specification Compliance Output voltage UOut compliant
- Standard - safety for equipment for measurement, control, and laboratory use IEC 61010-1
- UL approvals UL Listed UL 508
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Harmonic currents EN 61000-3-2
- DNV GL noise radiation Class B
- Comments Criterion A
- Input 2 kV (Test Level 4 - symmetrical)
- Installation distance right/left 5 mm / 5 mm
- Climatic class 3K3 (in acc. with EN 60721)
- AC frequency range 50 Hz ... 60 Hz -10 % ... +10 %
- Power factor (cos phi) 0.95
- Protective circuit/component Varistor, gas-filled surge arrester
- Dynamic Boost (IDyn.Boost) 60 A (5 s)
- Connection in series yes
- Output power 960 W
- Insulation voltage input/output 4 kV AC (type test)
- Protection class I
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section AWG max. 16
- EMC requirements, power plant IEC 61850-3
- Standard - Safety of transformers EN 61558-2-16
- Rail applications EN 50121-3-2
- SIQ BG (type approved)
- Additional text Test Level 2
- Electrostatic discharge EN 61000-4-2
- Fast transients (burst) EN 61000-4-4
- I/O/S asymmetrical
- Power frequency magnetic field EN 61000-4-8
- Damped oscillating magnetic field EN 61000-4-10
- Test level 6 16.7 Hz 50 Hz 60 Hz (Test Level 4)
- Signals (test level 2) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 9.0 27040701
- Contact discharge 8 kV (Test Level 4)
- Height 130 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Degree of pollution 2
- Input voltage range 3x 400 V AC ... 500 V AC -20 % ... +10 %
- Nominal power consumption 1217 VA
- Inrush current typ. 1.5 A (at 25 °C)
- Nominal output voltage 24 V DC
- Selective Fuse Breaking (ISFB) 215 A (15 ms)
- Feedback voltage resistance ≤ 35 V DC
- Typical response time 300 ms (from SLEEP MODE)
- Efficiency typ. 95.7 % (400 V AC)
- Insulation voltage output / PE 0.5 kV DC (type test)
- Conductor cross section solid max. 1 mm²
- Conductor cross section flexible min. 0.2 mm²
- Standard - Electrical safety IEC 61010-2-201 (SELV)
- Standard - Safe isolation IEC 61558-2-16
- Mains variation/undervoltage SEMI F47-0706, EN 61000-4-11
- Noise emission EN 55016
- Frequency range 50 Hz ... 60 Hz
- Surge voltage load (surge) EN 61000-4-5
- Voltage dip 0 %
- Test level 2 150 Hz 1.5 kHz (Test Level 4)
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Input, output (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- Signals (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- ETIM 7.0 EC002540
- Width 120 mm
- Degree of protection IP20
- Ambient temperature (start-up type tested) -40 °C
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Current consumption 3x 1.8 A (400 V AC)
- Mains buffering time typ. 28 ms (3x 400 V AC)
- Static Boost (IStat.Boost) 45 A
- Derating > 60 °C ... 70 °C (2.5%/K)
- Maximum power dissipation in no-load condition < 5 W (400 V AC)
- Environmental protection directive RoHS Directive 2011/65/EU
- Insulation voltage input / PE 3.5 kV AC (type test)
- Conductor cross section AWG min. 24
- EMC requirements for noise immunity EN 61000-6-1
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Shipbuilding approval DNV GL, BV, LR, ABS
- Flicker EN 61000-3-3
- DNV GL conducted interference Class A
- Electromagnetic HF field EN 61000-4-3
- Signal 4 kV (Test Level 2 - asymmetrical)
- Frequency 50 Hz
- Number of periods 0,5 / 1 / 5 / 50 / 250 periods
- Test level 4 15 kHz 150 kHz (Test Level 4)
- Input, output (test level 2) 10 MHz
- Criterion A Normal operating behavior within the specified limits.
- REACh SVHC Lead 7439-92-1
- ETIM 6.0 EC002540
- Installation distance top/bottom 50 mm / 50 mm
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Installation height ≤ 5000 m (> 2000 m, observe derating)
- Frequency range (fN) 50 Hz ... 60 Hz -10 % ... +10 %
- Recommended breaker for input protection 3x 4 A ... 20 A (Characteristic B, C, D, K or comparable)
- Setting range of the output voltage (USet) 24 V DC ... 29.5 V DC (constant capacity)
- Connection in parallel Yes, for redundancy and increased capacity
- Protection against overvoltage at the output (OVP) ≤ 32 V DC
- Net weight 2.6 kg
- Power loss nominal load max. < 45 W (400 V AC)
- Conductor cross section solid min. 0.2 mm²
- Stripping length 8 mm
- EMC requirements for noise emission EN 61000-6-3
- Standard – Safety extra-low voltage IEC 61010-1 (SELV)
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Conducted noise emission EN 55016
- Discharge in air 15 kV (Test Level 4)
- Test field strength 100 A/m
- Output 1 kV (Test Level 3 - symmetrical)
- Conducted interference EN 61000-4-6
- Pulse-shape magnetic field EN 61000-4-9
- Attenuated sinusoidal oscillations (ring wave) EN 61000-4-12
- Test level 5 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 4)
- Input, output (test level 3) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
- ECLASS 10.0.1 27040701
- Voltage dips EN 61000-4-11
- Test level 1 15 Hz 150 Hz (Test Level 4)
- Test level 3 1.5 kHz 15 kHz (Test Level 4)
- Attenuated oscillating wave EN 61000-4-18
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- ECLASS 11.0 27040701
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$563.45
Stock:
830
Select Qty:
$563.45
$563.45 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨