Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2904626 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2904626 Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, NFC interface, and protective coating, input: 1-phase, output: 48 V DC / 10 A
Phoenix Contact

Part#:2904626

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 26

Dec 22, 2024

Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, NFC interface, and protective coating, input: 1-phase, output: 48 V DC / 10 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2904626 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Mains variation/undervoltage
    SEMI F47-0706, EN 61000-4-11
  • CSA
    CAN/CSA-C22.2 No. 60950-1-07
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Contact discharge
    8 kV (Test Level 4)
  • Test field strength
    1000 A/m
  • Signal
    4 kV (Test Level 4 - asymmetrical)
  • I/O/S
    asymmetrical
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Input, output (test level 2)
    10 MHz
  • Installation distance top/bottom
    50 mm / 50 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Derating
    > 60 °C (2.5%/K)
  • Control deviation
    < 0.5 % (Static load change 10 % ... 90 %)
  • MTBF (IEC 61709, SN 29500)
    > 1100000 h (25 °C)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Conductor cross section AWG min.
    24
  • Surge voltage load (surge)
    EN 61000-4-5
  • Voltage dips
    EN 61000-4-11
  • Test level 2
    150 Hz 1.5 kHz (Test Level 3)
  • Input, output (test level 1)
    1 MHz (Test Level 3 - symmetrical)
  • Input, output (test level 3)
    1 MHz (Test Level 3 - asymmetrical)
  • Efficiency
    typ. 94 % (120 V AC)
  • Standard – Safety extra-low voltage
    IEC 61010-1 (SELV)
  • SIQ
    BG (type approved)
  • Flicker
    EN 61000-3-3
  • Input
    2 kV (Test Level 4 - symmetrical)
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Test level 3
    1.5 kHz 15 kHz (Test Level 3)
  • Attenuated oscillating wave
    EN 61000-4-18
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • Dielectric strength maximum
    300 V AC 60 s
  • Current consumption
    6.8 A (100 V AC)
  • Recommended breaker for input protection
    10 A ... 16 A (Characteristic B, C, D, K or comparable)
  • Static Boost (IStat.Boost)
    12.5 A
  • Height
    130 mm
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Protection against overvoltage at the output (OVP)
    ≤ 60 V DC
  • Conductor cross section flexible max.
    1.5 mm²
  • EMC requirements, power plant
    IEC 61850-3
  • Frequency range
    50 Hz ... 60 Hz
  • Criterion A
    Normal operating behavior within the specified limits.
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • Typical response time
    300 ms (from SLEEP MODE)
  • Insulation voltage input / PE
    3.5 kV AC (type test)
  • HART FSK Physical Layer Test Specification Compliance
    Output voltage UOut compliant
  • UL approvals
    UL Listed UL 508
  • Comments
    Criterion B
  • Conducted interference
    EN 61000-4-6
  • Frequency
    50 Hz
  • Test level 1
    15 Hz 150 Hz (Test Level 3)
  • ECLASS 11.0
    27040701
  • Height with alternative assembly
    130 mm
  • Inrush current
    typ. 11 A (at 25 °C)
  • Protective circuit/component
    Varistor, gas-filled surge arrester
  • Net weight
    1.3 kg
  • Width
    70 mm
  • Degree of protection
    IP20
  • Max. permissible relative humidity (operation)
    ≤ 100 % (at 25 °C, non-condensing)
  • Installation height
    ≤ 5000 m (> 2000 m, observe derating)
  • AC frequency range
    50 Hz ... 60 Hz -10 % ... +10 %
  • Mains buffering time
    typ. 32 ms (120 V AC)
  • Nominal output voltage
    48 V DC
  • Nominal output current (IN)
    10 A
  • Feedback voltage resistance
    ≤ 60 V DC
  • Maximum power dissipation in no-load condition
    < 5 W (120 V AC)
  • Insulation voltage input/output
    4 kV AC (type test)
  • Protection class
    I
  • Conductor cross section solid max.
    1 mm²
  • Conductor cross section AWG max.
    16
  • Standard - Safety of transformers
    IEC 61558-2-16 pending
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Shipbuilding approval
    DNV GL, PRS, BV, LR, ABS
  • Conducted noise emission
    EN 55016
  • Additional text
    Test Level 2
  • Discharge in air
    15 kV (Test Level 4)
  • Depth
    125 mm
  • Depth with alternative assembly
    73 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Frequency range (fN)
    50 Hz ... 60 Hz -10 % ... +10 %
  • Type of protection
    Transient surge protection
  • Dynamic Boost (IDyn.Boost)
    15 A (5 s)
  • Residual ripple
    < 70 mVPP (with nominal values)
  • Power loss nominal load max.
    < 36 W (120 V AC)
  • Insulation voltage output / PE
    0.5 kV DC (type test)
  • Connection method
    Push-in connection
  • Assembly instructions
    alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard - Electrical safety
    IEC 61010-2-201 (SELV)
  • Standard - safety for equipment for measurement, control, and laboratory use
    IEC 61010-1
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Harmonic currents
    EN 61000-3-2
  • DNV GL noise radiation
    Class B
  • Electromagnetic HF field
    EN 61000-4-3
  • Width with alternative assembly
    122 mm
  • Installation distance right/left
    5 mm / 5 mm
  • Ambient temperature (start-up type tested)
    -40 °C
  • Degree of pollution
    2
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Nominal power consumption
    519 VA
  • Discharge current to PE
    < 3.5 mA
  • Input fuse
    12 A (slow-blow, internal)
  • Setting range of the output voltage (USet)
    48 V DC ... 56 V DC (constant capacity)
  • Selective Fuse Breaking (ISFB)
    60 A (15 ms)
  • Connection in series
    yes
  • Output power
    480 W
  • Environmental protection directive
    RoHS Directive 2011/65/EU
  • Conductor cross section solid min.
    0.2 mm²
  • Stripping length
    8 mm
  • Conductor cross section flexible min.
    0.2 mm²
  • Standard - Safe isolation
    IEC 61010-2-201
  • Rail applications
    EN 50121-3-2
  • Noise emission
    EN 55016
  • DNV GL conducted interference
    Class A
  • Electrostatic discharge
    EN 61000-4-2
  • Fast transients (burst)
    EN 61000-4-4
  • Voltage
    2.5 kV
  • Number of periods
    0,5 / 1 / 5 / 50 / 250 periods
  • Attenuated sinusoidal oscillations (ring wave)
    EN 61000-4-12
  • Test level 6
    50 Hz 60 Hz (Test Level 3)
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Power frequency magnetic field
    EN 61000-4-8
  • Voltage dip
    0 %
  • Test level 5
    50 Hz 60 Hz (Test Level 3)
  • Test level 4
    15 kHz 150 kHz (Test Level 3)
  • ECLASS 9.0
    27040701
  • ECLASS 10.0.1
    27040701

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$499.05

Stock:

26

Select Qty:

$499.05

$499.05 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo