2904626 Phoenix Contact AC/DC Power Supplies
Part#:2904626
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 26
Dec 22, 2024
Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, NFC interface, and protective coating, input: 1-phase, output: 48 V DC / 10 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2904626 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Mains variation/undervoltage SEMI F47-0706, EN 61000-4-11
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Contact discharge 8 kV (Test Level 4)
- Test field strength 1000 A/m
- Signal 4 kV (Test Level 4 - asymmetrical)
- I/O/S asymmetrical
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Input, output (test level 2) 10 MHz
- Installation distance top/bottom 50 mm / 50 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Derating > 60 °C (2.5%/K)
- Control deviation < 0.5 % (Static load change 10 % ... 90 %)
- MTBF (IEC 61709, SN 29500) > 1100000 h (25 °C)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section AWG min. 24
- Surge voltage load (surge) EN 61000-4-5
- Voltage dips EN 61000-4-11
- Test level 2 150 Hz 1.5 kHz (Test Level 3)
- Input, output (test level 1) 1 MHz (Test Level 3 - symmetrical)
- Input, output (test level 3) 1 MHz (Test Level 3 - asymmetrical)
- Efficiency typ. 94 % (120 V AC)
- Standard – Safety extra-low voltage IEC 61010-1 (SELV)
- SIQ BG (type approved)
- Flicker EN 61000-3-3
- Input 2 kV (Test Level 4 - symmetrical)
- Pulse-shape magnetic field EN 61000-4-9
- Test level 3 1.5 kHz 15 kHz (Test Level 3)
- Attenuated oscillating wave EN 61000-4-18
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- Dielectric strength maximum 300 V AC 60 s
- Current consumption 6.8 A (100 V AC)
- Recommended breaker for input protection 10 A ... 16 A (Characteristic B, C, D, K or comparable)
- Static Boost (IStat.Boost) 12.5 A
- Height 130 mm
- Connection in parallel Yes, for redundancy and increased capacity
- Protection against overvoltage at the output (OVP) ≤ 60 V DC
- Conductor cross section flexible max. 1.5 mm²
- EMC requirements, power plant IEC 61850-3
- Frequency range 50 Hz ... 60 Hz
- Criterion A Normal operating behavior within the specified limits.
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Nominal input voltage range 100 V AC ... 240 V AC
- Typical response time 300 ms (from SLEEP MODE)
- Insulation voltage input / PE 3.5 kV AC (type test)
- HART FSK Physical Layer Test Specification Compliance Output voltage UOut compliant
- UL approvals UL Listed UL 508
- Comments Criterion B
- Conducted interference EN 61000-4-6
- Frequency 50 Hz
- Test level 1 15 Hz 150 Hz (Test Level 3)
- ECLASS 11.0 27040701
- Height with alternative assembly 130 mm
- Inrush current typ. 11 A (at 25 °C)
- Protective circuit/component Varistor, gas-filled surge arrester
- Net weight 1.3 kg
- Width 70 mm
- Degree of protection IP20
- Max. permissible relative humidity (operation) ≤ 100 % (at 25 °C, non-condensing)
- Installation height ≤ 5000 m (> 2000 m, observe derating)
- AC frequency range 50 Hz ... 60 Hz -10 % ... +10 %
- Mains buffering time typ. 32 ms (120 V AC)
- Nominal output voltage 48 V DC
- Nominal output current (IN) 10 A
- Feedback voltage resistance ≤ 60 V DC
- Maximum power dissipation in no-load condition < 5 W (120 V AC)
- Insulation voltage input/output 4 kV AC (type test)
- Protection class I
- Conductor cross section solid max. 1 mm²
- Conductor cross section AWG max. 16
- Standard - Safety of transformers IEC 61558-2-16 pending
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Shipbuilding approval DNV GL, PRS, BV, LR, ABS
- Conducted noise emission EN 55016
- Additional text Test Level 2
- Discharge in air 15 kV (Test Level 4)
- Depth 125 mm
- Depth with alternative assembly 73 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Climatic class 3K3 (in acc. with EN 60721)
- Frequency range (fN) 50 Hz ... 60 Hz -10 % ... +10 %
- Type of protection Transient surge protection
- Dynamic Boost (IDyn.Boost) 15 A (5 s)
- Residual ripple < 70 mVPP (with nominal values)
- Power loss nominal load max. < 36 W (120 V AC)
- Insulation voltage output / PE 0.5 kV DC (type test)
- Connection method Push-in connection
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- EMC requirements for noise immunity EN 61000-6-1
- Standard - Electrical safety IEC 61010-2-201 (SELV)
- Standard - safety for equipment for measurement, control, and laboratory use IEC 61010-1
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Harmonic currents EN 61000-3-2
- DNV GL noise radiation Class B
- Electromagnetic HF field EN 61000-4-3
- Width with alternative assembly 122 mm
- Installation distance right/left 5 mm / 5 mm
- Ambient temperature (start-up type tested) -40 °C
- Degree of pollution 2
- Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
- Nominal power consumption 519 VA
- Discharge current to PE < 3.5 mA
- Input fuse 12 A (slow-blow, internal)
- Setting range of the output voltage (USet) 48 V DC ... 56 V DC (constant capacity)
- Selective Fuse Breaking (ISFB) 60 A (15 ms)
- Connection in series yes
- Output power 480 W
- Environmental protection directive RoHS Directive 2011/65/EU
- Conductor cross section solid min. 0.2 mm²
- Stripping length 8 mm
- Conductor cross section flexible min. 0.2 mm²
- Standard - Safe isolation IEC 61010-2-201
- Rail applications EN 50121-3-2
- Noise emission EN 55016
- DNV GL conducted interference Class A
- Electrostatic discharge EN 61000-4-2
- Fast transients (burst) EN 61000-4-4
- Voltage 2.5 kV
- Number of periods 0,5 / 1 / 5 / 50 / 250 periods
- Attenuated sinusoidal oscillations (ring wave) EN 61000-4-12
- Test level 6 50 Hz 60 Hz (Test Level 3)
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- Output 1 kV (Test Level 3 - symmetrical)
- Power frequency magnetic field EN 61000-4-8
- Voltage dip 0 %
- Test level 5 50 Hz 60 Hz (Test Level 3)
- Test level 4 15 kHz 150 kHz (Test Level 3)
- ECLASS 9.0 27040701
- ECLASS 10.0.1 27040701
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$499.05
Stock:
26
Select Qty:
$499.05
$499.05 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨