3044160 Phoenix Contact Terminal Blocks

Phoenix Contact 3044160 Feed-through terminal block, nom. voltage: 1000 V, nominal current: 57 A, connection method: Screw connection, number of connections: 2, cross section: 0.5 mm² - 16 mm², AWG: 20 - 6, width: 10.2 mm, height: 46.9 mm, color: gray, mounting type: NS 35/7,5,
Phoenix Contact

Part#:3044160

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 1952

Dec 26, 2024

Feed-through terminal block, nom. voltage: 1000 V, nominal current: 57 A, connection method: Screw connection, number of connections: 2, cross section: 0.5 mm² - 16 mm², AWG: 20 - 6, width: 10.2 mm, height: 46.9 mm, color: gray, mounting type: NS 35/7,5,

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3044160 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Result of temperature-rise test
    Test passed
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Length
    47.7 mm
  • ECLASS 10.0.1
    27141120
  • Note
    Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • ETIM 2.0
    EC000897
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Conductor cross section flexible max.
    16 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.5 mm²
  • UNSPSC 21.0
    39121410
  • UNSPSC 11
    39121410
  • ETIM 3.0
    EC000897
  • UNSPSC 6.01
    30211811
  • UNSPSC 7.0901
    39121410
  • UNSPSC 20.0
    39121410
  • 2 conductors with same cross section, stranded max.
    4 mm²
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • UNSPSC 19.0
    39121410
  • UNSPSC 13.2
    39121410
  • Rated surge voltage
    8 kV
  • Nominal voltage UN
    1000 V
  • Bending test conductor cross section/weight
    0.5 mm² / 0.3 kg
  • Maximum load current
    76 A (with 16 mm² conductor cross section)
  • Open side panel
    Yes
  • Surge voltage test setpoint
    9.6 kV
  • Tensile test result
    Test passed
  • Short circuit stability result
    Test passed
  • Result of thermal test
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2018-05
  • Test duration per axis
    5 h
  • Shock duration
    18 ms
  • Static insulating material application in cold
    -60 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Screw thread
    M4
  • Tightening torque, min
    1.5 Nm
  • Shock test result
    Test passed
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Result of surge voltage test
    Test passed
  • Bending test rotation speed
    10 rpm
  • Conductor cross section short circuit testing
    10 mm²
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Degree of pollution
    3
  • Nominal current IN
    57 A
  • Back of the hand protection
    guaranteed
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • ASD level
    6.12 (m/s2)2/Hz
  • Number of shocks per direction
    3
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height NS 35/15
    55 mm
  • Connection method
    Screw connection
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of power-frequency withstand voltage test
    Test passed
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Width
    10.2 mm
  • Height
    46.9 mm
  • Stripping length
    10 mm
  • Conductor cross section flexible min.
    0.5 mm²
  • Short-time current
    1.2 kA
  • Acceleration
    30g
  • Shock form
    Half-sine
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Connection in acc. with standard
    CSA
  • Conductor cross section solid min.
    0.5 mm²
  • ECLASS 11.0
    27141120
  • Conductor cross section AWG max.
    6
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    10 mm²
  • Internal cylindrical gage
    A6
  • Tightening torque max
    1.8 Nm
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.5 mm²
  • 2 conductors with same cross section, stranded min.
    0.5 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.5 mm²
  • ECLASS 5.1
    27141100
  • Max. AWG conductor cross section, flexible
    6
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 4.1
    27141100
  • ECLASS 9.0
    27141120
  • Potentials
    1
  • Area of application
    Railway industry
  • Bending test turns
    135
  • Test spectrum
    Service life test category 2, bogie-mounted
  • End cover width
    2.2 mm
  • Flammability rating according to UL 94
    V0
  • Result of tight fit on support
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Maximum power dissipation for nominal condition
    1.82 W
  • Tractive force setpoint
    100 N
  • Setpoint
    5 N
  • Number of levels
    1
  • Color
    gray
  • Finger protection
    guaranteed
  • Result of flexion and pull-out test
    Test passed
  • Result of voltage-drop test
    Test passed
  • Tight fit on carrier
    NS 35
  • Conductor cross section tensile test
    16 mm²
  • Requirements, voltage drop
    U1 ≤ 3.2 mV; U2 ≤ 1.5 x U1
  • Height NS 35/7,5
    47.5 mm
  • Conductor cross section AWG min.
    20
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 5.0
    27141100
  • Insulating material group
    I
  • Conductor cross section solid max.
    16 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 4.0
    27141100
  • ECLASS 7.0
    27141120
  • ETIM 7.0
    EC000897
  • UNSPSC 18.0
    39121410
  • Nominal cross section
    10 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    10 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    6 mm²
  • Insulating material
    PA
  • 2 conductors with same cross section, solid max.
    4 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    2.5 mm²
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 6.0
    27141100
  • ETIM 6.0
    EC000897
  • UNSPSC 12.01
    39121410
  • Number of connections
    2
  • Min. AWG conductor cross section, flexible
    20
  • 2 conductors with same cross section, solid min.
    0.5 mm²
  • Overvoltage category
    III
  • ETIM 4.0
    EC000897

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$2.81

Stock:

1,952

Select Qty:

$2.81

$2.81 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo