Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2904611 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2904611 Primary-switched QUINT POWER power supply for DIN rail mounting with free choice of output characteristic curve and SFB (Selective Fuse Breaking) technology, input: 1-phase, output: 48 V DC / 10 A
Phoenix Contact

Part#:2904611

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 41

Dec 22, 2024

Primary-switched QUINT POWER power supply for DIN rail mounting with free choice of output characteristic curve and SFB (Selective Fuse Breaking) technology, input: 1-phase, output: 48 V DC / 10 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2904611 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Width with alternative assembly
    122 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • Discharge current to PE
    < 3.5 mA
  • Inrush current
    typ. 11 A (at 25 °C)
  • Nominal output current (IN)
    10 A
  • Static Boost (IStat.Boost)
    12.5 A
  • Typical response time
    300 ms (from SLEEP MODE)
  • Efficiency
    typ. 94 % (120 V AC)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Conductor cross section solid max.
    1 mm²
  • EMC requirements, power plant
    IEC 61850-3
  • Standard - Electrical safety
    IEC 61010-2-201 (SELV)
  • Standard - safety for equipment for measurement, control, and laboratory use
    IEC 61010-1
  • Conducted noise emission
    EN 55016
  • Additional text
    Test Level 2
  • Electrostatic discharge
    EN 61000-4-2
  • Test field strength
    110 A/m
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Voltage
    2.5 kV
  • Number of periods
    0,5 / 1 / 5 / 50 / 250 periods
  • Depth
    125 mm
  • Degree of protection
    IP20
  • Ambient temperature (start-up type tested)
    -40 °C
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Current consumption
    6.8 A (100 V AC)
  • Type of protection
    Transient surge protection
  • Setting range of the output voltage (USet)
    48 V DC ... 56 V DC (constant capacity)
  • Connection in series
    yes
  • Output power
    480 W
  • Environmental protection directive
    RoHS Directive 2011/65/EU
  • Insulation voltage input/output
    4 kV AC (type test)
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible min.
    0.2 mm²
  • Standard - Safety of transformers
    IEC 61558-2-16 pending
  • Standard – Safety extra-low voltage
    IEC 61010-1 (SELV)
  • UL approvals
    UL Listed UL 508
  • Rail applications
    EN 50121-3-2
  • DNV GL conducted interference
    Class A
  • Frequency range
    50 Hz ... 60 Hz
  • Fast transients (burst)
    EN 61000-4-4
  • Frequency
    50 Hz
  • Test level 1
    15 Hz 150 Hz (Test Level 4)
  • Test level 2
    150 Hz 1.5 kHz (Test Level 4)
  • Test level 6
    16.7 Hz 50 Hz 60 Hz (Test Level 4)
  • Signals (test level 1)
    100 kHz 1 MHz (Test Level 3 - symmetrical)
  • REACh SVHC
    Lead 7439-92-1
  • Width
    70 mm
  • Depth with alternative assembly
    73 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Degree of pollution
    2
  • Frequency range (fN)
    50 Hz ... 60 Hz -10 % ... +10 %
  • Input fuse
    12 A (slow-blow, internal)
  • Protective circuit/component
    Varistor, gas-filled surge arrester
  • Selective Fuse Breaking (ISFB)
    60 A (15 ms)
  • Protection against overvoltage at the output (OVP)
    ≤ 60 V DC
  • Residual ripple
    < 70 mVPP (with nominal values)
  • Power loss nominal load max.
    < 36 W (120 V AC)
  • Insulation voltage output / PE
    0.5 kV DC (type test)
  • Assembly instructions
    alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
  • Stripping length
    8 mm
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Mains variation/undervoltage
    SEMI F47-0706, EN 61000-4-11
  • CSA
    CAN/CSA-C22.2 No. 60950-1-07
  • Noise emission
    EN 55016
  • DNV GL noise radiation
    Class B
  • Discharge in air
    15 kV (Test Level 4)
  • Input
    2 kV (Test Level 4 - symmetrical)
  • Surge voltage load (surge)
    EN 61000-4-5
  • Power frequency magnetic field
    EN 61000-4-8
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Attenuated sinusoidal oscillations (ring wave)
    EN 61000-4-12
  • Test level 4
    15 kHz 150 kHz (Test Level 4)
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 10.0.1
    27040701
  • Height with alternative assembly
    130 mm
  • Installation distance right/left
    5 mm / 5 mm
  • Installation height
    ≤ 5000 m (> 2000 m, observe derating)
  • Dielectric strength maximum
    300 V AC 60 s
  • Mains buffering time
    typ. 32 ms (120 V AC)
  • Nominal output voltage
    48 V DC
  • Derating
    > 60 °C ... 70 °C (2.5%/K)
  • Feedback voltage resistance
    ≤ 60 V DC
  • Control deviation
    < 0.5 % (Static load change 10 % ... 90 %)
  • Net weight
    1.3 kg
  • MTBF (IEC 61709, SN 29500)
    > 1100000 h (25 °C)
  • Protection class
    I
  • Connection method
    Push-in connection
  • Conductor cross section AWG max.
    16
  • HART FSK Physical Layer Test Specification Compliance
    Output voltage UOut compliant
  • Standard - Safe isolation
    IEC 61558-2-16 pending
  • Shipbuilding approval
    DNV GL, PRS, BV, LR, ABS
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Flicker
    EN 61000-3-3
  • Electromagnetic HF field
    EN 61000-4-3
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Conducted interference
    EN 61000-4-6
  • Voltage dip
    0 %
  • Test level 3
    1.5 kHz 15 kHz (Test Level 4)
  • Input, output (test level 2)
    10 MHz
  • Signals (test level 2)
    100 kHz 1 MHz (Test Level 3 - asymmetrical)
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 9.0
    27040701
  • Height
    130 mm
  • Installation distance top/bottom
    50 mm / 50 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Climatic class
    3K3 (in acc. with EN 60721)
  • AC frequency range
    50 Hz ... 60 Hz -10 % ... +10 %
  • Nominal power consumption
    519 VA
  • Recommended breaker for input protection
    10 A ... 16 A (Characteristic B, C, D, K or comparable)
  • Dynamic Boost (IDyn.Boost)
    15 A (5 s)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Maximum power dissipation in no-load condition
    < 5 W (120 V AC)
  • Insulation voltage input / PE
    3.5 kV AC (type test)
  • Conductor cross section flexible max.
    1.5 mm²
  • Conductor cross section AWG min.
    24
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Harmonic currents
    EN 61000-3-2
  • Contact discharge
    8 kV (Test Level 4)
  • Comments
    Criterion A
  • I/O/S
    asymmetrical
  • Voltage dips
    EN 61000-4-11
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Test level 5
    16.7 Hz 50 Hz 60 Hz (Test Level 4)
  • Input, output (test level 3)
    100 kHz 1 MHz (Test Level 3 - asymmetrical)
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • ETIM 6.0
    EC002540
  • Damped oscillating magnetic field
    EN 61000-4-10
  • Attenuated oscillating wave
    EN 61000-4-18
  • Input, output (test level 1)
    100 kHz 1 MHz (Test Level 3 - symmetrical)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 11.0
    27040701
  • ETIM 7.0
    EC002540

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$488.31

Stock:

41

Select Qty:

$488.31

$488.31 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo