Primary-switched QUINT POWER power supply for DIN rail mounting with free choice of output characteristic curve and SFB (Selective Fuse Breaking) technology, input: 1-phase, output: 48 V DC / 10 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at marketplace.quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2904611 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width with alternative assembly 122 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Nominal input voltage range 100 V AC ... 240 V AC
- Discharge current to PE < 3.5 mA
- Inrush current typ. 11 A (at 25 °C)
- Nominal output current (IN) 10 A
- Static Boost (IStat.Boost) 12.5 A
- Typical response time 300 ms (from SLEEP MODE)
- Efficiency typ. 94 % (120 V AC)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section solid max. 1 mm²
- EMC requirements, power plant IEC 61850-3
- Standard - Electrical safety IEC 61010-2-201 (SELV)
- Standard - safety for equipment for measurement, control, and laboratory use IEC 61010-1
- Conducted noise emission EN 55016
- Additional text Test Level 2
- Electrostatic discharge EN 61000-4-2
- Test field strength 110 A/m
- Signal 1 kV (Test Level 2 - asymmetrical)
- Voltage 2.5 kV
- Number of periods 0,5 / 1 / 5 / 50 / 250 periods
- Depth 125 mm
- Degree of protection IP20
- Ambient temperature (start-up type tested) -40 °C
- Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
- Current consumption 6.8 A (100 V AC)
- Type of protection Transient surge protection
- Setting range of the output voltage (USet) 48 V DC ... 56 V DC (constant capacity)
- Connection in series yes
- Output power 480 W
- Environmental protection directive RoHS Directive 2011/65/EU
- Insulation voltage input/output 4 kV AC (type test)
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible min. 0.2 mm²
- Standard - Safety of transformers IEC 61558-2-16 pending
- Standard – Safety extra-low voltage IEC 61010-1 (SELV)
- UL approvals UL Listed UL 508
- Rail applications EN 50121-3-2
- DNV GL conducted interference Class A
- Frequency range 50 Hz ... 60 Hz
- Fast transients (burst) EN 61000-4-4
- Frequency 50 Hz
- Test level 1 15 Hz 150 Hz (Test Level 4)
- Test level 2 150 Hz 1.5 kHz (Test Level 4)
- Test level 6 16.7 Hz 50 Hz 60 Hz (Test Level 4)
- Signals (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- REACh SVHC Lead 7439-92-1
- Width 70 mm
- Depth with alternative assembly 73 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of pollution 2
- Frequency range (fN) 50 Hz ... 60 Hz -10 % ... +10 %
- Input fuse 12 A (slow-blow, internal)
- Protective circuit/component Varistor, gas-filled surge arrester
- Selective Fuse Breaking (ISFB) 60 A (15 ms)
- Protection against overvoltage at the output (OVP) ≤ 60 V DC
- Residual ripple < 70 mVPP (with nominal values)
- Power loss nominal load max. < 36 W (120 V AC)
- Insulation voltage output / PE 0.5 kV DC (type test)
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- Stripping length 8 mm
- EMC requirements for noise immunity EN 61000-6-1
- Mains variation/undervoltage SEMI F47-0706, EN 61000-4-11
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Noise emission EN 55016
- DNV GL noise radiation Class B
- Discharge in air 15 kV (Test Level 4)
- Input 2 kV (Test Level 4 - symmetrical)
- Surge voltage load (surge) EN 61000-4-5
- Power frequency magnetic field EN 61000-4-8
- Pulse-shape magnetic field EN 61000-4-9
- Attenuated sinusoidal oscillations (ring wave) EN 61000-4-12
- Test level 4 15 kHz 150 kHz (Test Level 4)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 10.0.1 27040701
- Height with alternative assembly 130 mm
- Installation distance right/left 5 mm / 5 mm
- Installation height ≤ 5000 m (> 2000 m, observe derating)
- Dielectric strength maximum 300 V AC 60 s
- Mains buffering time typ. 32 ms (120 V AC)
- Nominal output voltage 48 V DC
- Derating > 60 °C ... 70 °C (2.5%/K)
- Feedback voltage resistance ≤ 60 V DC
- Control deviation < 0.5 % (Static load change 10 % ... 90 %)
- Net weight 1.3 kg
- MTBF (IEC 61709, SN 29500) > 1100000 h (25 °C)
- Protection class I
- Connection method Push-in connection
- Conductor cross section AWG max. 16
- HART FSK Physical Layer Test Specification Compliance Output voltage UOut compliant
- Standard - Safe isolation IEC 61558-2-16 pending
- Shipbuilding approval DNV GL, PRS, BV, LR, ABS
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Flicker EN 61000-3-3
- Electromagnetic HF field EN 61000-4-3
- Output 1 kV (Test Level 3 - symmetrical)
- Conducted interference EN 61000-4-6
- Voltage dip 0 %
- Test level 3 1.5 kHz 15 kHz (Test Level 4)
- Input, output (test level 2) 10 MHz
- Signals (test level 2) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 9.0 27040701
- Height 130 mm
- Installation distance top/bottom 50 mm / 50 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Climatic class 3K3 (in acc. with EN 60721)
- AC frequency range 50 Hz ... 60 Hz -10 % ... +10 %
- Nominal power consumption 519 VA
- Recommended breaker for input protection 10 A ... 16 A (Characteristic B, C, D, K or comparable)
- Dynamic Boost (IDyn.Boost) 15 A (5 s)
- Connection in parallel Yes, for redundancy and increased capacity
- Maximum power dissipation in no-load condition < 5 W (120 V AC)
- Insulation voltage input / PE 3.5 kV AC (type test)
- Conductor cross section flexible max. 1.5 mm²
- Conductor cross section AWG min. 24
- EMC requirements for noise emission EN 61000-6-3
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Harmonic currents EN 61000-3-2
- Contact discharge 8 kV (Test Level 4)
- Comments Criterion A
- I/O/S asymmetrical
- Voltage dips EN 61000-4-11
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Test level 5 16.7 Hz 50 Hz 60 Hz (Test Level 4)
- Input, output (test level 3) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- ETIM 6.0 EC002540
- Damped oscillating magnetic field EN 61000-4-10
- Attenuated oscillating wave EN 61000-4-18
- Input, output (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 11.0 27040701
- ETIM 7.0 EC002540
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$488.31
Stock:
41
Select Qty:
$488.31
$488.31 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨