8BVI0220HWD0.000-1 B&R Electronic Components
Part#:8BVI0220HWD0.000-1
Manufacturer:B&R
Product Lifecycle:Active
In-stock parts: 3
Dec 27, 2024
ACOPOSmulti inverter module, 22 A, AS, wall mounting, 2 axes
Check out the 8BVI0220HWD0.000-1 B&R price in the box on the right side or send a quick quote.
Product Details
- Weight5.7 kg
- Dimensions Width 106.5 mm
- Installation elevation above sea level Maximum 4000 m
- Switching threshold High >15 V
- Switching delay at nominal input voltage Enable 0 → 1, ready for PWM Max. 100 µs
- Temperature Operation Maximum 55°C
- Terminal connection cross section Approbation data CSA 28 to 10 AWG
- Temperature Operation Nominal 5 to 40°C
- Terminal connection cross section Approbation data UL/C-UL-US 30 to 10 AWG
- Dimensions Depth Wall mounting 263 mm
- Dimensions Height 317 mm
- Terminal connection cross section Flexible and fine-stranded wires With wire end sleeves 0.25 to 6 mm²
- Relative humidity Storage 5 to 95%
- Temperature Storage -25 to 55°C
- Relative humidity Operation 5 to 85%
- Temperature Transport -25 to 70°C
- Relative humidity Transport Max. 95% at 40°C
- Permissible mounting orientations Standing horizontally No
- Installation elevation above sea level Nominal 0 to 500 m
- Permissible mounting orientations Horizontal, face up Yes
- Permissible mounting orientations Hanging vertically Yes
- Switching threshold Low <5 V
- Switching delay Falling edge 53 µs ±0.5 µs (digitally filtered)
- Switching delay Rising edge 52 µs ±0.5 µs (digitally filtered)
- Input voltage Maximum 30 VDC
- Switching delay at nominal input voltage Enable 1 → 0, PWM off Max. 20.5 ms
- Electrical isolation Input - Input Yes
- Electrical isolation Input - Inverter module Yes
- Input voltage Nominal 24 VDC
- Max. motor line length depending on switching frequency Switching frequency 10 kHz 25 m
- Protective measures Overload and short-circuit protection Yes
- Max. motor line length depending on switching frequency Switching frequency 5 kHz 25 m
- Protective measures Open-circuit monitoring Yes
- Protective measures Undervoltage monitoring Yes
- Protective measures Overload protection Yes
- Variant U, V, W, PE Connector
- Reduction of continuous current depending on switching frequency Switching frequency 5 kHz 0.33 A/K (starting at 40°C)
- Protective measures Short-circuit and ground fault protection Yes
- Variant Shield connection Yes
- Reduction of continuous current depending on installation elevation Starting at 500 m above sea level 2.2 Aeff per 1000 m
- Output voltage DC bus voltage (UDC): 315 to 800 VDC 24 VDC ±6%
- Reduction of continuous current depending on switching frequency Switching frequency 10 kHz 0.17 A/K (starting at -25°C)
- Output voltage DC bus voltage (UDC): 260 to 315 VDC 25 VDC * (UDC/315)
- Certifications KC Yes
- Power dissipation depending on switching frequency Switching frequency 5 kHz [0.65 * IM² - 0.35 * IM+ 64] W
- Power dissipation depending on switching frequency Switching frequency 10 kHz [2.16 * IM² - 10.912 * IM+ 190] W
- Module width 2
- Voltage Nominal 750 VDC
- Certifications Functional safety Yes
- Certifications EAC Yes
- Certifications UL cULus E225616; Power conversion equipment
- Pollution degree per EN 61800-5-1 2 (non-conductive pollution)
- Degree of protection per EN 60529 IP20
- Overvoltage category per EN 61800-5-1 III
- Certifications CE Yes
- OSSD signal connections Permitted ; Max. test pulse length: 500 µs
- Output voltage 24 VDC +5.8% / -0%
- Input current at nominal voltage Approx. 30 mA
- Modulation compared to ground potential Max. ±38 V
- Discharge capacitance 0.44 µF
- Max. switching frequency 0.5 Hz
- Max. internal resistance 0.3 Ω
- Extinction potential Approx. 30 V
- Response threshold for undervoltage monitoring 24 VDC +0% / -4%
- Circuit Sink
- Continuous current 2.1 A
- Possible switching frequencies 5 / 10 kHz
- Response threshold for open-circuit monitoring Approx. 0.5 A
- Terminal cable cross section dimension of shield connection 12 to 22 mm
- Max. extinction energy per switching operation 3 Ws
- Insulation stress of the connected motor per IEC TS 60034-25:2004 Limit value curve A
- Max. output frequency 598 Hz
- Continuous current per motor connection 22 Aeff
- Continuous power per motor connection 16 kW
- Fuse protection 250 mA (slow-blow) electronic, automatic reset
- Nominal switching frequency 5 kHz
- Peak current per motor connection 55 Aeff
- Quantity 2
- Max. power consumption 21 W + PSLOT1 + PSLOT2 + P24 V Out + PHoldingBrake(s)
- Input voltage 25 VDC ±1.6%
- DC bus capacitance 1320 µF
- Cooling and mounting type Wall mounting
- Variant ACOPOSmulti backplane
- Slots for plug-in modules 2
- Input capacitance 23.5 µF
- Continuous power consumption 32.37 kW
- B&R ID code 0xA8E6
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
Related documents 8BVI0220HWD0.000-1 Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price within minutes.
Stock:
3
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of B&R
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
B&R Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨